���Iw����,�"��rcW�ii1Flk�#�oads E.N1s.9oRnr�+s . ±p�,,hc.
<br /> �►. . ����c. ��
<br /> � ,:_�{. . 2
<br /> Pro'ect Report
<br /> k����-;�`�°,yi�,:�,:._,.r:'`',�;,r,.�'; o;.: . , -r= ., k''y� • _ , �. _ �t+y.m- -. p,;,�;,a�` i .��
<br /> x ,¢�T' ,,�`;�, �'�"�;,y�.
<br /> Project Title: Thornton Residence
<br /> Designed By: Robert Vela
<br /> Project Date: Tuesday, October 23, 2012
<br /> I Client Name: James Thornton
<br /> Client Address: 38015 Lawanda Loop
<br /> Client City: Zephyrhills FI 33542
<br /> Company Name: ACE AMERICAN HOME
<br /> Company Representative• ROBERT VELA
<br /> Company Address. 6008 JETPORT INDUSTRIAL BLVD
<br /> Company City: TAMPA, FL,33634
<br /> Company Phone. 813-445-4818
<br /> Company E-Mail Address. OFFICEQa COMFORTISCOOL.COM
<br /> Company Website: WWW COMFORTISCOOL.COM
<br /> ".�:':;#4?`:F 'k;, � s. � .. s - - ',: _ � .. :.
<br /> ::3�.::„ > � � -' �'- , .ur_ .,°�.:„';�Y'v'..�.�,k,=' :�."
<br /> Reference City: Tampa, Florida
<br /> Building Orientation: Front door faces South
<br /> Daily Temperature Range: Medium
<br /> Latitude. 28 Degrees
<br /> Elevation: 19 ft.
<br /> Altitude Factor: p.ggg
<br /> Elevation Sensible Adj. Factor� 1.000
<br /> Elevation Total Adj. Factor: 1.000
<br /> ; Elevation Heating Adj. Factor: 1.000
<br /> Elevation Heating Adj. Factor 1.000
<br /> Outdoor Outdoor Outdoor Indoor Indoor Grains '
<br /> Drv Bulb Wet Bulb Rel.Hum Rel.Hum Drv Bulb Difference
<br /> Winter: 40 37.52 80% n/a 70 n/a
<br /> Summer: 95 77 45% 50% 75 46 I
<br /> I
<br /> ;- ,.a.�y.-;, , ;,.:�>- _ � � . �,:,, .
<br /> � � u�.�g:: _ . . _, �::-v:,:... :�:.,•;:;;,�,;-: '
<br /> Total Building Supply CFM: 1,581 CFM Per Square��ft.: 1,1g5 *
<br /> Square ft. of Room Area: 1,323 Square ft. Per Ton: 385
<br /> Volume (ft3) of Cond. Space. (clg.) 11,907
<br /> * Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area.
<br /> k ,. � ,:. s,.,.�.�a� ��:;;;. - , ;� � � �,: m;•,
<br /> - : „���,�:_�-
<br /> Total Sensible Gain: 36,960 Btuh 90 %
<br /> Total LatentGain. 4,284 Btuh ip %
<br /> Total Cooling Required Including Ventilation Air• 41,244 Btuh 3.44 Tons(Based On Sensible+ Latent)
<br /> �'�':^~�..;t..�;...,,..x= + -.>.,. . .
<br /> . .�Y .,ka'.914l�,:SJ.�`� Ft !. ..� � . . .^.�S,Y.;'x�;:;?•-�
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program �'�}��
<br /> I Calculations are performed per ACCA Manual J 8th Edition, Version 2,and ACCA Manual D. i
<br /> � All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.