GENERAL NOTES <br />1. All wires at Control Panel must be tagged and marked in order for SimplexGrinnell <br />Technical Representatives to make final connections. <br />2. All wires and shields to be free of shorts and grounds. <br />3. A MINIMUM of 3/4' conduit shall be used. All conduit should be sized per NFPA 70 <br />(NEC). The following conditions shall be maintained: <br />a) EMT in ceiling spaces. <br />b) Rigid conduit or PVC in slabs with rigid elbows. <br />If Flex conduit is used, the following applies: <br />a) Flex conduit runs shall NOT exceed 72 ". <br />b) Only Metal Flex shall be used. <br />C This drawing depicts general locations of Life Safety equipment & field devices. Exact <br />routing of conduits to be determined in the field by the Installing Contractor to suit <br />conditions. All changes shall be clearly indicated on the record drawings. <br />NFPA 72 2007 (Section 10.6.1.1). <br />5. Device locations and quantities must be confirmed with approved Fire Alarm shop <br />drowing submittals. Any discrepancies which exist between the approved shop drawings <br />and the contract documents shall remain the responsibility of the Installing Contractor. <br />6. Should any conditions exist that differ from what is indicated on these drawings <br />which cause major deviations in the work shown, the Contractor shall contact <br />SimplexGrinnell Engineers in a timely manner so as not to impair the construction <br />schedule. <br />7. The Contractor is responsible for making and obtaining approval for all necessary <br />adjustments in circuiting as required to accommodate the relocation of equipment <br />and /or devices which are affected by any authorized change. All changes shall be <br />clearly indicated on the record drawings. NFPA 72 2007 (Section 10.6.1.1). <br />8. Wiring and mounting of Fire Alarm devices may NOT begin until a Fire Alarm Permit <br />has been issued by the Authority Having Jurisdiction, by order of the Fire Marshal. <br />9. NFPA 72, Audible/Visual and Visual only devices shall be mounted with the entire lens <br />between 80' and 96' above the finished floor (NFPA 72 2007 Section 7.5.4). Refer <br />to equipment data sheets for exact backbox mounting heights. If ADA applies, Strobes <br />shall be mounted at 80" to the bottom of the Strobe lens (ADAAG Section 4.28.3 (6) <br />10. Manual Pull Station shall be not less than 3 1/2 ft (1.1 M) and not more than <br />4, 1/2 ft (1.37 M) from operable part of device to finished floor level and within <br />5 ft of doorway opening, per NFPA 72 2007 (Section 5.13.4 and 5.13.6). <br />11. Provide dedicated 120vac circuits to the Fire Alarm Control Panel and NAC Panels. <br />Lobel dedicated circuit "Fire Alarm System" and place lock out on circuit at the <br />Electrical Panel. NFPA 72 2007 (Section 4.4.1.4). <br />12. Existing conduits may be used by Installation Contractor as deemed necessary. <br />However, any existing conduit will be used only if conduits meet current standards <br />and codes. SimplexGrinnell makes NO statements written or verbal as to the condition <br />of the existing conduit. <br />13. Installing Contractor to verify audibility level of the Audible devices and field adjust <br />to ensure audibility is in compliance with NFPA 72 2007 (Section A.7.4.2) min. <br />14. DO NOT install Smoke Detector heads until all major construction and cleaning is <br />complete. Cleaning of detector heads contaminated by construction duct will be <br />billable. NFPA 72 2007 (Section 5.7.1.11). <br />SOUND LEVELS <br />NFPA 72, 7.4.2.12007 Edition <br />LEGEND <br />To ensure that audible public mode signals are clearly heard, unless otherwise permitted <br />by 7.4.2.2 through 7.4.2.5, they shall have a sound level at least 15 dB above the average <br />ambient sound level or 5 dB above the maximum sound level having a duration of at least <br />60 seconds, whichever is greater, measured 1.5 m (5 <br />ft) above the floor in the occupioble <br />are, using A- weighted scale (dBA). <br />ABOVE FINISHED FLOOR <br />NFPA 72, TABLE A7.4.2 2007 Edition <br />Average Ambient Sound Level According to Location <br />Location <br />Average Ambient <br />MEETS THE SOUND LEVEL OUTPUT <br />Sound Level (dBA) <br />Business occupancies <br />55 <br />Educational occupancies <br />45 <br />Industrial occupancies <br />80 <br />Institutional occupancies <br />50 <br />Mercantile occupancies <br />40 <br />Mechanical rooms <br />85 <br />Piers and water - surrounded structures <br />40 <br />Places of assembly <br />55 <br />Residential occupancies <br />35 <br />Storage occupancies <br />30 <br />Thoroughfares, high density urban <br />70 <br />Thoroughfares, medium density urban <br />55 <br />Thoroughfares, rural density urban <br />40 <br />Tower occupancies <br />35 <br />Underground structures and <br />40 <br />windowless buildings <br />OVERALL SHIELD (YELLOW) <br />Vehicles and vessels <br />50 <br />PRIMARY POWER SUPPLY <br />NFPA 72 2007 CHAPTER 4.4.L4 Primary Power Supply. <br />CHAPTER 4.4.1.4.1 Dedicated Branch Circuit. A dedicated branch circuit of one of the following <br />shall supply primary power. <br />CHAPTER 4.4.1.4.2 Mechanical Protection. <br />4.4.1.4.2.1 The dedicated branch circuit(s) and connections shall be mechanically <br />protected. <br />4.4.1.4.2.2 Circuit disconnecting means shall have a red marking, shall be accessible only to <br />authorized personnel, and shall be identified as "FIRE ALARM CIRCUIT'. <br />4.4.1.4.2.3 The location of the circuit disconnecting means shall be permanently identified at <br />the fire alarm control unit. <br />SCOPE OF WORK <br />Add to existing Fire Alarm System as shown on the drawings. <br />All wiring to be "CLASS B'. Wiring is "STYLE Y' for Notification Appliance Circuits. 'STYLE B" <br />for Initiating Device Circuits and STYLE 4" for Signaling Line Circuits. <br />New initiating devices will tie to existing IDnet. <br />New Notification device strobe circuit will tie to New NAC Expander panel. <br />New Notification device speaker circuit will tie to existing circuit <br />Trip new NAC Expander panel from existing IDnet. <br />DEVICE MOUNTING HEIGHTS (PER NFPA 72) NFPA 72 2002 EDmoN <br />NFPA 72 2007 EDITION <br />(SECTION A.5.6.3.1) <br />THE 4' REQUIREMENT FOR SMOKE DETECTORS HAS <br />BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 <br />4' NOTE: MEASUREMENTS <br />(102mm) SHOWN ARE TO THE <br />CEILING CLOSEST EDGE OF THE <br />�1I ITN -�7 DETECTOR. <br />VICOILING MOUNTED 4" <br />SMOKE/HEAT <br />DETECTOR 0 o�mm) 12' MAX) <br />(305mm MAX) <br />ACCEPTED HERE NEAT DETECTORS <br />NEVER HERE <br />NFPA 72 2010 EDITION <br />WALL MOUNTED (SECTION 17.7.3.2.1) <br />SMOKE/HEAT <br />DETECTOR <br />VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS <br />1. MIN DISTANCE IN SLEEPING ROOMS IS 24' (61Omm) TO TOP OF LENS <br />FOR 11OCD STROBES WITHIN 16' OF THE PILLOW <br />2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24' <br />(610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER <br />INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. <br />FOR CEILING HEIGHTS LESS THAN 86' (2180mm), <br />THE VISUAL LENS MOUNTING HEIGHT SHALL BE <br />WITHIN 5" (150mm) OF THE CEILING. AUDIBLE ONLY <br />AUDIBLE/VISUAL <br />& VISUAL ONLY <br />APPLIANCES <br />SYNCHRONIZE MORE THAN <br />TWO APPLIANCES IN ANY <br />FIELD OF VIEW. <br />NFPA 72 2002 EDITION <br />(SECTION A.75.4.3) <br />NFPA 72 2007 EDITION <br />(SECTION A.7.5.4.5) <br />NFPA 72 2010 EDITION <br />(SECTION 18,5.4,3.2(4)) <br />REF. 80' MIN (IBC) <br />(2032mm MIN) <br />REF. 96" MAX (IBC) <br />(2440mm MAX) <br />ABOVE FINISHED FLOOR <br />80" (ADA) <br />80" MIN (NFPA) <br />NFPA 72 2002 EDITION <br />(SECTION 7.5.4) <br />NFPA 72 2007 EDITION <br />(SECTION 7.5.4.1) <br />NFPA 72 2010 EDITION <br />(SECTION 18.5.4.1)' <br />NOTE: REFER TO THE PROPER DEVICE <br />INSTALLATION INSTRUCTIONS <br />FOR BACKBOX MOUNTING HEIGHT. <br />96' MAX (NFPA) <br />(2440mm MAX) <br />ABOVE FINISHED FLOOR <br />(2032mm) <br />(2032mm MIN) <br />FINISHED <br />FLOOR <br />A/C SUPPLY <br />OR RETURN <br />DIFFUSER <br />i <br />3' (MIN) <br />(914mm MIN) <br />NFPA 72 AUDIBLE APPLIANCE <br />LEGEND <br />6" MIN (152.4mm MIN) <br />DESCRIPTION <br />BELOW FINISHED CEILING <br />MOUNTING HEIGHTS <br />90" MIN (2286mm MIN) <br />NOTIFICATION APPLIANCE CABINET <br />ABOVE FINISHED FLOOR <br />NON- PLENUM RATED: FPL <br />(OTHER MOUNTING HIEGHTS SHALL <br />BE <br />PERMITTED BY THE AW PROVIDING IT <br />MEETS THE SOUND LEVEL OUTPUT <br />REQUIRED.) <br />FIRE ALARM TERMINAL CABINET <br />FURNISH BY OTHERS <br />TO EXIT DOOR <br />© <br />MANUAL PULL STATION <br />5' (MAX.) <br />48' TO CENTER OF DEVICE AFF <br />.5W # <br />(1524mm) DOOR <br />WIDTH <br />PAIGE 454722AREM <br />80 <br />PAIGE 454717AREM <br />LESS 3 <br />SIMPLEXGRINNELL 4906 -9151 <br />82' TO BOTTOM OF BACKBOX AFF <br />160 <br />6mm) <br />AREA = 0.0755 SQ. INCH AREA = 0.1085 SO. INCH <br />208 <br />BELDEN 5320FJ <br />STROBE <br />WALL MOUNT <br />MANUAL <br />80' TO BOTTOM OF BACKBOX AFF <br />17 <br />'#" DENOTES CANDELA <br />49 <br />PULL <br />EOL <br />END -OF -LINE RESISTOR <br />(SIZE & QTY) TO BE DETERMINED IN FIELD <br />1 PAIR, 1S AWG, TWISTED <br />OVERALL SHIELD (YELLOW) <br />STATION <br />(USE RESISTOR CHART AS A GUS <br />NON - PLENUM RATED: FPL <br />O <br />FIRE <br />SIMPLEXGRINNELL 4098 -9714 <br />5' <br />(127mm) <br />PHONE <br />ANIXTER SG1802S10 -03 <br />MAGNETIC <br />JACK <br />68 <br />AREA = 0.0320 SQ. INCH <br />AREA= 0.0186 SO. INCH <br />DOOR <br />o <br />® <br />PAIGE 454722AREM <br />HOLDER <br />PAIGE 454717ARE <br />PAIGE 73182CI PAIGE 73182CIC <br />48" MAX (ADA) <br />(1219mm) <br />42" MIN /54' MAX (NFPA) <br />(1067mm MIN /1372mm MAX <br />NFPA 72 2002 EDITION <br />35 <br />(SECTION 5.12.4) <br />BELDEN 5320FL <br />NFPA 72 2007 EDITION <br />NFPA 72 2010 EDITION <br />(SECTION 5.13.4) <br />(SECTION 17.14.4) <br />IMPORTANT NOTICE TO USER <br />By accepting or using this drawing and /or the information contained herein, the user agrees to the <br />following terms and conditions: The electronic information in the drawing may be subject to intentional <br />or unintentional alteration. Any use, reuse, copying modification or alteration of the information <br />contained herein shall be at the sole risk of the user. This information may not be sold or transferred <br />to any third party, used on other projects or additions to the project for which it was prepared, or <br />used for completion of this project by any third party. SimplexGrinnell disclaims all liability for the use <br />or reuse of altered files by the user or any third party and such use will be a users sole risk. User <br />shall, to the fullest extent permitted by law, defend, indemnify, and hold SimplexGrinnell harmless from <br />n any and all claims for loss, damage or injury arising directly or indirectly therefrom. <br />FIRE ALARM <br />LEGEND <br />SYMBOL <br />DESCRIPTION <br />VENDOR / PART NUMBER <br />MOUNTING HEIGHTS <br />PAIR, 18 AWG, TWISTED OVERALL SHIELD (RED) <br />NOTIFICATION APPLIANCE CABINET <br />M <br />NON- PLENUM RATED: FPL <br />NAC <br />w /6.2M BATTERY SETS <br />SIMPLEXGRINNELL 4009- 9201 <br />60' TO CENTER OF PANEL <br />FATC I <br />FIRE ALARM TERMINAL CABINET <br />FURNISH BY OTHERS <br />• <br />© <br />MANUAL PULL STATION <br />SIMPLEXGRINNELL 4099- 9001 <br />48' TO CENTER OF DEVICE AFF <br />.5W # <br />SPEAKER /STROBE <br />PAIGE 454722AREM <br />80 <br />PAIGE 454717AREM <br />WALL. MOUNT <br />SIMPLEXGRINNELL 4906 -9151 <br />82' TO BOTTOM OF BACKBOX AFF <br />160 <br />'.25W' DENOTES WATT TAP ' #' DENOTES CANDELA <br />AREA = 0.0755 SQ. INCH AREA = 0.1085 SO. INCH <br />208 <br />BELDEN 5320FJ <br />STROBE <br />WALL MOUNT <br />SIMPLEXGRINNELL 4906 - 9101 <br />80' TO BOTTOM OF BACKBOX AFF <br />17 <br />'#" DENOTES CANDELA <br />49 <br />AREA= 0.0269 SQ. INCH <br />EOL <br />END -OF -LINE RESISTOR <br />(SIZE & QTY) TO BE DETERMINED IN FIELD <br />1 PAIR, 1S AWG, TWISTED <br />OVERALL SHIELD (YELLOW) <br />2 HOUR RATED <br />(USE RESISTOR CHART AS A GUS <br />NON - PLENUM RATED: FPL <br />O <br />SMOKE DETECTOR <br />SIMPLEXGRINNELL 4098 -9714 <br />' <br />ANIXTER SG1802S19 -03 <br />ANIXTER SG1802S10 -03 <br />SIMPLEXGRINNELL 4098 -9792 <br />50 <br />FINISHED <br />WALL <br />SIDE WALL <br />215 110 <br />(Total CKT Load: 0.924 amps) V2 <br />Re 1` <br />(X3) (x1) (0) 2S <br />V <br />75 25W <br />(Total CKT Load: 0.634 a 15 <br />amps) V1 EOL Re <br />(x3) (XI) (6) <br />V <br />CABLE TROUGH <br />NAC FATC <br />4009 <br />DEDICATED 200 VAC '00 MUNO OF" <br />srslor <br />CR !"D Two _ <br />0WM0'A`%ff6V MM M,2S <br />M (x2) (0) <br />TO EXISTING <br />PARTIAL SYSTEM RISER <br />FIRE ALARM SYSTEM <br />NOT TO SCALE <br />ON <br />NOT U: <br />DIP <br />SWITCHES <br />1 THRU 4 <br />IDNET ADDRESS CHART <br />MSB <br />DIPSWITCH IS SHOWN <br />g JX SET AT ADDRESS 2 <br />I -ONIM O -OFF19 <br />I DIP SWITCHES 5 THRU 8 <br />ED <br />FIRE ALARM WERE LIST <br />1000 <br />IDNET CIRCUIT - 1 <br />PAIR, 18 AWG, TWISTED OVERALL SHIELD (RED) <br />2 HOUR RATED <br />M <br />NON- PLENUM RATED: FPL <br />1110 <br />PLENUM RATED: FPLP <br />NON- PLENUM RATED: FPLR -CI NON- PLENUM RATED: FPL -NPFL <br />0101 <br />ANIXTER S131802S19 -03 <br />0011 <br />AND(TER SG1802S21 -03 <br />0111 <br />1111 <br />AREA = 0.0320 SQ. INCH <br />0 <br />AREA= 0.0177 SQ. INCH <br />32 <br />48 <br />PAIGE 454722AREM <br />80 <br />PAIGE 454717AREM <br />PAIGE 73182CI PAIGE 73182CIC <br />128 <br />AREA -- 0.0224 SQ. INCH <br />160 <br />AREA= 0.0219 SQ. INCH <br />AREA = 0.0755 SQ. INCH AREA = 0.1085 SO. INCH <br />208 <br />BELDEN 5320FJ <br />240 <br />BELDEN 6320FJ <br />BELDEN 5320FM <br />17 <br />AREA--0.0350 SQ. INCH <br />49 <br />AREA= 0.0269 SQ. INCH <br />AREA = 0.0774 SQ. INCH <br />97 <br />SPEAKER CIRCUIT - <br />1 PAIR, 1S AWG, TWISTED <br />OVERALL SHIELD (YELLOW) <br />2 HOUR RATED <br />S <br />NON - PLENUM RATED: FPL <br />NON- PLENUM RATED: FPLR <br />PLENUM RATED: FPLP <br />NON - PLENUM RATED: FPLR -CI NON- PLENUM RATED: FPL -NPFL <br />0100 <br />ANIXTER SG1802S19 -03 <br />ANIXTER SG1802S10 -03 <br />ANIXTER SG1802S21 -03 <br />50 <br />68 <br />AREA = 0.0320 SQ. INCH <br />AREA= 0.0186 SO. INCH <br />AREA= 0.0177 SQ. INCH <br />130 <br />146 <br />PAIGE 454722AREM <br />PAIGE 454722ARE <br />PAIGE 454717ARE <br />PAIGE 73182CI PAIGE 73182CIC <br />226 <br />AREA--0.0224 SQ. INCH <br />AREA= 0.0204 SQ. INCH <br />AREA= 0.0219 SQ. INCH <br />AREA =0.0755 SQ. INCH AREA = 0.1085 SQ, INCH <br />35 <br />BELDEN 5320FJ <br />BELDEN 5320FL <br />BELDEN 6320FK <br />BELDEN 532OFM <br />115 <br />AREA = 0.0350 SO. INCH <br />AREA = 0.0189 SO. INCH <br />AREA= 0.0269 SQ. INCH <br />AREA = 0.0714 SO. INCH <br />195 <br />VISUAL /SIGNAL CIRCUIT - 2 CONDUCTOR, 14 <br />AWG SOLID (ORANGE /BROWN') <br />2 HOUR RATED <br />V <br />NON- PLENUM RATED: FPLR <br />CONDUIT ONLY: THHN <br />PLENUM RATED: FPLP <br />NON- PLENUM RATED: FPLR -CI NON- PLENUM RATED: FPL -NPFL <br />68 <br />ANIXTER SG1402N10 -03 <br />ANIXTER <br />ANIXTER SG1402N21 -03 <br />ANIXTER SG1402N40 -03 <br />148 <br />AREA--0.0340 SQ. INCH <br />AREA= 0.0097 SQ. INCH <br />AREA= 0.0308 SQ. INCH <br />AREA = 0.1018 SO. INCH <br />228 <br />PAIGE 454718RE <br />PAIGE 740252RDBK <br />PAIGE 454719ARE <br />PAIGE 73142CI PAIGE 73142CIC <br />37 <br />AREA= 0.0380 SQ. INCH <br />AREA= 0.0394 SO. INCH <br />AREA= 0.0333 SO. INCH <br />AREA = 0.1195 SO. INCH AREA = 0.1195 SQ. INCH <br />117 <br />BELDEN 512OUL <br />BELDEN <br />BELDEN 6120UL <br />BELDEN 51 20U BELDEN 5120OZ <br />197 <br />AREA -- 0.0356 SQ. INCH <br />AREA= 0.0097 SQ. INCH <br />AREA= 0.0330 SO. INCH <br />AREA = 0.1018 SO. INCH AREA = 0.1134 SQ. INCH <br />5 <br />CONDUIT SIM <br />38 <br />CONDWOR AREA <br />CONDUIT SM <br />CONDUCTON AREA <br />NOTE: <br />WHEN THE ADM LISTED GABLES ARE INSTALLED N CONDUIT (REQUIRET) FOR CIC LISTED GABLES) <br />1/2- <br />3/4' <br />0.12 SQ NCH • <br />0.21 SQ NCH • <br />1-1/4' <br />1 -1 2' <br />0.00 so I" <br />082 gQ { • <br />182 <br />1' <br />214 <br />0.34 SQ NCH • <br />248 <br />Z( <br />1.34 s4 NCH • <br />ONLY CIRCUIT NTEGRITY CABLES CAN BE NSTALED IN THAT CONDUIT. <br />THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED ELECTRIC& CHARACTERISTICS AS <br />• 40x FILL PER N.E.C. <br />55 <br />71 <br />CONTACT <br />YOUR LOCAL 8MPLEXC <br />i1M1E11. OF�10E <br />WEIL AS CODE REQUIREM MS. ALTERNATE SUPPLIERS MAY BE SUBSTITUTED PROMNG <br />151 <br />167 <br />183 <br />199 <br />EQUNALEM CHARACTERMM ARE MAINTAINED , M3AS SUCH AS CAPACITANCE BETWEEN <br />231 <br />FOR ANY CABLE SUBSTTTUTKM <br />0001 <br />CONDUCTORS AND WIRE GAUGE CM BE CM Ai. TO THE CIRCUIT DESIGN OF THIS srsa INSTALLATION. <br />FINISHED <br />WALL <br />SIDE WALL <br />215 110 <br />(Total CKT Load: 0.924 amps) V2 <br />Re 1` <br />(X3) (x1) (0) 2S <br />V <br />75 25W <br />(Total CKT Load: 0.634 a 15 <br />amps) V1 EOL Re <br />(x3) (XI) (6) <br />V <br />CABLE TROUGH <br />NAC FATC <br />4009 <br />DEDICATED 200 VAC '00 MUNO OF" <br />srslor <br />CR !"D Two _ <br />0WM0'A`%ff6V MM M,2S <br />M (x2) (0) <br />TO EXISTING <br />PARTIAL SYSTEM RISER <br />FIRE ALARM SYSTEM <br />NOT TO SCALE <br />ON <br />NOT U: <br />DIP <br />SWITCHES <br />1 THRU 4 <br />IDNET ADDRESS CHART <br />MSB <br />DIPSWITCH IS SHOWN <br />g JX SET AT ADDRESS 2 <br />I -ONIM O -OFF19 <br />aa.. <br />0 <br />J <br />Lu X <br />Z (n <br />4 <br />. �� <br />a. <br />Iq W <br />cri <br />�Q <br />0 <br />O <br />1� <br />V <br />Q <br />Div LL 0N0 ONO M <br />M { <br />® Im fD fD ei <br />L m Q tND tN0 (D <br />0 <br />Q. MMM <br />LL IS DO 00 00 <br />v° Q u- LJ.I <br />V� Q UJ <br />F1 <br />i <br />0 <br />U <br />Z <br />O <br />a <br />N <br />Q <br />0 <br />W <br />R <br />0 <br />d <br />Z <br />O <br />I,-,, N <br />E-4 W U <br />E-1 H <br />co <br />J <br />[� LL <br />Z DO _ <br />Z w �oQ <br />F+4 F+4 r% ti N <br />DRAWN BY: DATE: <br />J,SERRANO 30- JULY -2012 <br />CONFIGURED BY: DATE: <br />J.SERF I 30- JULY -2012 <br />REVIEWED BY: DATE: <br />J.SERRANO 30- JULY -2012 <br />PROJECT NUMBER: <br />965620413 <br />SHEET TITLE: <br />GENERAL INFORMATION <br />FIRE ALARM SYSTEM <br />SHEET NUMBER: <br />FA -002 <br />I DIP SWITCHES 5 THRU 8 <br />ED <br />0000 <br />1000 <br />0100 <br />1100 <br />0010 <br />1010 <br />0110 <br />1110 <br />0001 <br />1001 <br />0101 <br />1101 <br />0011 <br />1011 <br />0111 <br />1111 <br />0000 <br />0 <br />16 <br />32 <br />48 <br />64 <br />80 <br />96 <br />112 <br />128 <br />144 <br />160 <br />178 <br />192 <br />208 <br />224 <br />240 <br />1000 <br />1 <br />17 <br />33 <br />49 <br />65 <br />81 <br />97 <br />113 <br />129 <br />145 <br />161 <br />177 <br />193 <br />209 <br />225 <br />241 <br />0100 <br />2 <br />18 <br />34 <br />50 <br />68 <br />82 <br />98 <br />114 <br />130 <br />146 <br />162 <br />118 <br />194 <br />210 <br />226 <br />142 <br />1100 <br />3 <br />19 <br />35 <br />51 <br />67 <br />83 <br />99 <br />115 <br />131 <br />147 <br />183 <br />179 <br />195 <br />211 <br />227 <br />243 <br />0010 <br />4 <br />20 <br />38 <br />52 <br />68 <br />84 <br />100 <br />116 <br />132 <br />148 <br />164 <br />180 <br />196 <br />212 <br />228 <br />244 <br />1010 <br />5 <br />21 <br />37 <br />53 <br />69 <br />85 <br />101 <br />117 <br />133 <br />149 <br />165 <br />181 <br />197 <br />213 <br />229 <br />245 <br />0110 <br />5 <br />22 <br />38 <br />54 <br />70 <br />86 <br />102 <br />118 <br />134 <br />150 <br />166 <br />182 <br />198 <br />214 <br />230 <br />248 <br />1110 <br />7 <br />23 <br />39 <br />55 <br />71 <br />87 <br />103 <br />119 <br />135 <br />151 <br />167 <br />183 <br />199 <br />215 <br />231 <br />247 <br />0001 <br />8 <br />1 24 <br />40 <br />56 <br />72 <br />88 <br />104 <br />120 <br />136 <br />152 <br />168 <br />184 <br />200 <br />216 <br />232 <br />248 <br />1001 <br />9 <br />F 25 <br />41 <br />57 <br />73 <br />89 <br />1D5 <br />121 <br />137 <br />153 <br />169 <br />185 <br />201 <br />217 <br />233 <br />249 <br />0101 <br />10 1 <br />26 <br />42 <br />58 <br />74 <br />90 <br />106 <br />122 <br />138 <br />154 <br />170 <br />186 <br />202 <br />218 <br />234 <br />250 <br />1101 <br />11 1 <br />27 <br />43 <br />59 <br />75 1 <br />91 <br />107 <br />123 <br />139 <br />155 <br />171 <br />187 1 <br />203 <br />219 <br />235 <br />0011 <br />12 <br />28 <br />44 <br />60 <br />76 <br />92 <br />108 <br />124 <br />140 <br />156 <br />172 <br />188 <br />204 <br />220 <br />238 <br />1011 <br />13 <br />29 <br />45 <br />61 <br />77 <br />93 <br />109 <br />125 <br />141 <br />157 <br />173 <br />189 <br />205 <br />221 <br />237 <br />0111 <br />14 <br />30 <br />48 <br />62 <br />78 <br />94 <br />110 <br />126 <br />158 <br />174 <br />190 <br />208 <br />222 <br />238 <br />1111 <br />15 <br />31 <br />47 <br />63 <br />79 <br />95 <br />111 <br />127 <br />E143 <br />-1-59-Fl <br />59 <br />7_ <br />175 <br />191 <br />207 <br />223 <br />239 <br />aa.. <br />0 <br />J <br />Lu X <br />Z (n <br />4 <br />. �� <br />a. <br />Iq W <br />cri <br />�Q <br />0 <br />O <br />1� <br />V <br />Q <br />Div LL 0N0 ONO M <br />M { <br />® Im fD fD ei <br />L m Q tND tN0 (D <br />0 <br />Q. MMM <br />LL IS DO 00 00 <br />v° Q u- LJ.I <br />V� Q UJ <br />F1 <br />i <br />0 <br />U <br />Z <br />O <br />a <br />N <br />Q <br />0 <br />W <br />R <br />0 <br />d <br />Z <br />O <br />I,-,, N <br />E-4 W U <br />E-1 H <br />co <br />J <br />[� LL <br />Z DO _ <br />Z w �oQ <br />F+4 F+4 r% ti N <br />DRAWN BY: DATE: <br />J,SERRANO 30- JULY -2012 <br />CONFIGURED BY: DATE: <br />J.SERF I 30- JULY -2012 <br />REVIEWED BY: DATE: <br />J.SERRANO 30- JULY -2012 <br />PROJECT NUMBER: <br />965620413 <br />SHEET TITLE: <br />GENERAL INFORMATION <br />FIRE ALARM SYSTEM <br />SHEET NUMBER: <br />FA -002 <br />