Laserfiche WebLink
352-498-7852 10.59:38 a.m. 05-11-2012 4/5 <br /> i <br /> i--�.. <br /> � � T` <br /> Force Fn�ineeizil�;&Test3ng Tttic. <br /> 195iU Ltyrihlc�roud Drice <br /> liuml�le,-E'K 7733t! <br /> Cade Compliance: The product described herein has demonstrated compliance with <br /> The Florida BuEld(ng Code 2010,Section 15D43.2,1504.7. <br /> Evaluation Report Scope: The produ�t evaluatlon is iim{ted ta compllance with the structurai wind load <br /> requirements of the Florida Building Code 2010,as relates to Rule 9N-3. <br /> Perfarmance Standards: The product described herein�has demonstrated compfian�e with: <br /> m UL 590-D6-Test for Uplift Resistance of Roof Assemblfes <br /> ■ UL 1897-04-Uplift Test for Roaf Covering Systems <br /> • FM 4471,Section 5.4-Foot Traffic Resistance Test <br /> Reference data; 1. UL 580-94/1897-98 UpiiftTest <br /> Force Engineering&Testing,Inc,(F8C Organfxation#TST-5328) <br /> Report N�.117-00407T-09,Dated 11/16/09 <br /> 2. FM 4471-95,Section 5,4 Foot Trafflc Resistance Test <br /> Force Engineering&Testing,Inc.{FBC Organfzation#TS7-5328f <br /> Report No.217-d238T-09�,Dated 07j21/2009 <br /> 3. Certificate of fndependence <br /> By Terrence E.Walfe,P.E,(No,44923)@ Force[ngineering&Testing,Inc. <br /> (FBC Organization#ANE I0:1920) <br /> Test Standard Equivalency: 1. The UL 58D-94 test standard is equivalent to the Ul 580-06 test standard. <br /> 2. The UL 1897-98 test standard is equlvalent to the UL 1897-04 test standard, <br /> QuaHty ltssurance Entity: The manufacturer has estab(ished compllance of roaf panel produ�ts in <br /> accordance with the florida Building Code and Rule 9N-3.005(3)for <br /> manuFacturing under a quality`assurance program audited by an apprnved <br /> quality assurance entity. <br /> Mi�imum Slope Range: Min(mum Slope shall compfy with Florida Building Code 201D,inciudfng5ection <br /> 1507.4.2 and in accordance with Manufacturers re�ommendations. For slopes <br /> less than 3:12, lap sealant must be used in the panel side laps. <br /> lnstallation: Install per rnanufa�ture�'s recommended details. <br /> Undertayment: Per Manufacturer's installation guidelines per Florlda Building Code Z010 5ection <br /> 1507.4.5. <br /> ,���ttti�t►�re�� <br /> �`�t f��•�E'�'•� ��s <br /> � <br /> :,'t"��4 , C E N S fi{��,,` <br /> •;"r� . <br /> � � <br /> �� _ "°.•�� �,����--�, <br /> f � � _ �5 <br /> `� . � '�i-+�?�.�'�-�' ' <br /> �"�+' STATE OP �ac�f <br /> r�+', <br /> ;°,�. AZ oRr9�`,•��'�: <br /> s f� *,f`s.i ,��ti�,+ <br /> I�r��r������♦�` � <br /> FL#17651.27 RI F�bruarv 22_ 2012 <br />