My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13765
Zephyrhills
>
Building Department
>
Permits
>
2013
>
12-13765
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2013 11:10:05 AM
Creation date
9/13/2013 11:10:02 AM
Metadata
Fields
Template:
Building Department
Company Name
OAK RUN
Building Department - Doc Type
Permit
Permit #
12-13765
Building Department - Name
PADGETT,DEBBIE
Address
7252 HIGHLAND LP
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R W R W Building Consultants, Inc. <br /> B Consulting and Engineering Services for the Building Industry <br /> C P O.Box 230 Valrico,PL 33595 Phone 813 659.9197 <br /> Florida Board of ProPessional Enb�neers Certificate of Authorization No 9813 <br /> Product Sub Category Manufacturer Product Name <br /> Category <br /> Doers�ndow Manufacturing,LLC DuraGard <br /> Windows Double Hung 4901 Oak Fafr Bivd Double Hung Wndow <br /> Tampa,FL 33610 "Non-ImpacY' <br /> (813 626-6000 <br /> Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F Schmidt, P.E. (System ID#1998)for <br /> Doers Window Manufacturing, LLC,based on Rule Chapter No 9N-3,Method 1A of the State of Florida Product Approval, <br /> Dept.of Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F Schmidt, P E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named <br /> herein. <br /> Limifations: <br /> 1 This product has been evaluated and is in compliance with the 2010 Florida Building Code(FBC)structural requirements excluding the <br /> "High Velocity Hurricane Zone"(HVHZ).See the Certification Agency Certificate for sizes,specifications and ratings. <br /> 2. Product anchors shali be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco. <br /> 3. When used in areas requiring wind borne debris protection,this product is required to be protected with an impact resistant covering <br /> that complies with Section 1609 1.2 of the Florida Building Code. <br /> 4 For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. <br /> 5 Site conditions that deviate from the details of drawing FL-15385.4 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6 See drawing FL-15385.4 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1 Test Reaort No. Test Standard Testinq Laboratorv Si4ned bv <br /> ATI 83299 03-501-44-r1 AAMA/WDMA/CSA 101/1.S.2/A440-05 Architectural Testing,Inc. Lynn George <br /> ATI 83936 03-501-44-r1 AAMA/VVDMA/CSA 101lI.S.2lA440-05 Architectural Testing,Inc. Lynn George <br /> 2. Drawinq No. Prepared bv Si4ned 8�Sealed bv <br /> No FL-15385.4 RW Building Consultants,Inc.(CA#9813) Lyndon F Schmidt, P E. <br /> 3 Calculations Preaared bv Siqned 8 Sealed bv <br /> Anchoring RW Building Consultants,Inc. (CA#9813) Lyndon F Schmidt, P.E. <br /> 4 Quality Assurance <br /> Certificate of Participation issued by Keystone Certifications, Inc.,certifying that Doers Window Manufacturing, LLC is <br /> manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. /�,_� <br /> G , <br /> Lyndon F Schmidt,P.E. <br /> FL PE No 43409 <br /> 3/28/2012 <br /> PF 1651 Sheet 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.