Laserfiche WebLink
FORMS <br /> TABLE 402A �� <br /> BUILDINCa COMPONENT PERFORMANCE CRITERIA' INSTALLED VALUES: <br /> U-Factor<0.65 U-Factor= <br /> Windows(see Note 2): SHGC=0.30 SHGC= <br /> %ofCFA<=20% <br /> %of CFA= <br /> S li hts U-Factor<0.75 <br /> Doors:Exterior door U-Factor U-Factor<0.65 -Factor= <br /> Floors: Slab-on-grade No requirement <br /> Over unconditioned s aces see Note 3 R-13 Value= <br /> Walls–Ext.and Adj.(see Note 3): <br /> Frame R-13 R- alue= <br /> Mass (see Note 3) <br /> Inierior of wall: R-7.8 R- lue= <br /> Exterior of wall: R-6 F-V lue= <br /> Ceilings(see Notes 3&4) R=30 R-V lue= Test report <br /> Reflectance 025 Refl ctance= Attached. <br /> Yes/No <br /> Air distribution system(see Note 4) <br /> Ductwork&air handling unit: Lo ation: Test report <br /> Unconditioned space Not allowed Attached? <br /> Conditioned space Yes/No <br /> Duct R-va�ue R-value?6 -Value= <br /> Air teakage Qn Qn<0.03 �_ <br /> Air conditionin s stems see Note 5 SEER=13.0 SEER= <br /> Heating system <br /> Heat pump(see Note 5) Cooling: SEER=13.0 SEEF= <br /> Heating: HSPF=77 FISPF= , <br /> Gas(umace AFUE 78% AFUE= I, <br /> Oil furnace AFUE 78`6 AFUE= j <br /> Electric resistance:Not allowed(see Note 5) � <br /> —� <br /> Water heating system(storage type) � <br /> Electric(see Note 6): 40 gal:EF=0.92 Gallons= I <br /> 50 gal:EF=0.90 EF= i <br /> Gas fired(see Note 7): 40 gal:EF=0.59 Gallons= I, <br /> Other(describe): 50 gaC EF=0.58 EF= <br /> (1)Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in orderto comply with this code using this method; <br /> otherwise Section 405 compliance must be used. <br /> (2)Windows and doors qualifying as glazed fenestration areas mustcompiywiih both the maximum U-Factorand the maximum SHGC(solarHeat Gain Coefficient)criteria <br /> and have a maximum total window area equal to or less than 20%of the conditioned floor area(CFA);othenvise Section 405 must be used for compliance. <br /> Exception: Additions of 600 square feet(56 m2)or less may have a maximum glass to CFA of 50 percent. <br /> (3)R-values are for insulation material only as applied in accordance with manufacturers'installation instructions.For mass walls,the"interior of wall"requirement must be <br /> met except if at leasi 50%of the R-6 insulation required for the"exterior of wall"is installed exterior of,or integral to,the wall. <br /> (4)Ducts&AHU insialled substantially leak free per Section 4032.2.1 Test by Class 1 BERS rater required. <br /> Exception:Ducts installed onto an existing air distribution system as part of an addition or renovation;duct must be R-6 installed per Sec.5032.7.2. <br /> (5)For all conventional units with capacities greater than 30,000 Btu/hr. For other types of equipment,see Tables 5032.3(1-8). <br /> Exception:The prohibition on eiectric resistance heat does not apply to additions,renovations and new heating systems installed in existing buildings. <br /> (6)For other efectric storage volumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For other natural gas storage volumes,minimum EF=0.67-(0.0019 x volume). <br /> TABLE 402B MANDATORY REQUIREMENTS <br /> COMPONENTS SECTION REQUIREMENTS CHECK <br /> To be caulked,gasketed,weatherstripped or otherwise sealed.Recessed lighting IC-rated as meeting ASTM E <br /> Air leakage 402.4 263.Windows and doors=0.30 cfm/sq.ft.Testing or visual inspection required.Fireplaces:gasketed doors& �/ <br /> outdoor combustion air. <br /> Ceilings/knee walls 405.2.1 R-19 space permitting. ✓ <br /> Programmable thermostat 403.1 1 Where forced-air furnace is primary system,programmable thermostat is required. ✓ <br /> Air distribution system 4032 Ducts in attics or on roofs insulated to R-8;other ducts R-6.Ducts tested to Q,=0.03 by a Class 1 BERS rater �/ <br /> Heat trep required for vertical pipe risers.Compiy with e�ciencies in Table 403.4.32.Provide swrtch or clearly <br /> Water heaters 403.4 marked circuit breaker(electric)or shutoff(gas).Circulating system pipes insulated to=R-2+accessible manual <br /> OFF switch. <br /> Spas and heated poois must have vapor•retardant covers or a liquid cover or other means proven to reduce heat <br /> Swimming pool&spas 403.9 loss except if 7DM of heat from site-recovered energy.OffRimer switch required.Gas heaters minimum thermal <br /> efficien =78% 82%after 4/16/13.Heat um ool heaters minimum COP=4.0. <br /> Sizing calculation performed&attached.Minimum efficiencies per Tables 503.2.3.Equipment efficiency verification <br /> Cooling/hea[ing equipment 403.6 required.Special occasion cooling or heating capacity requires separate sysiem or variable capacity system. <br /> Electric heat>10kW must be divided into two or more sta es. <br /> Lighting equipment 404.1 At least 50%of permanently installed lighting fixtures shall be high-efficacy lamps. <br /> 2010 FLORIDA BUILDING CODE—ENERGY CONSERVATION C.5 <br />