Laserfiche WebLink
COMPATIBLE INTELLIGENT DEVICES FCM-1: FkashScan NAC control modufe See DN-6720.. <br /> BEAMHK: Heating kit for transmittedreceiver unit of FSB- FCM-I-REL: FlashScan releasing control module See DN- <br /> 200(S)beiow See DN-6985. 60390. <br /> BEAMHKR: Heating kit for use with the reflector of FSB- FRM-1: FlashScan rekay module. See DN-6720.. <br /> 200(S)below. See DN-6985. FDRM-1: FlashScan dual monitor/duai refay module. See DN- <br /> BEAMLRK: Long-range accessory kit, FSB-200(S) below 60709 <br /> See DN-6985 NBG-12LX: Manual pull station,addressable. See DN-6726.. <br /> BEAMMKR: Muiti-mount kit, FSB-200(S) below. See DIV- �SO-X: Isolator moduVe. See DN-2243. See DN-2243. <br /> 6985. <br /> XP6-C: FlashScan six-circuit supervised control module. See <br /> BEAMSMK: Surface-mount kit, FSB-200(S) below See DN- DN-6924 <br /> 6985. <br /> XP6-MA: FlashScan six-zone interface module, connects <br /> FSB-20Q: Inteliigent beam smoke detector See DN-6985. intelligent alarm system to two-wire conventional detection <br /> FSB-200S: Intelligent beam smoke detector with integral sen- zone. See DN-6325 <br /> sitivity test. See DN-6985. XP6-R: FlashScan six-relay (Form-C) control module See <br /> FSC-851: FlashScan IntelliQ�ad Advanced Multi-Criteria DN-6326. <br /> Detector See DIV-60412. XP10-M: FlashScan ten-input monitor module. See DN-6923. <br /> FCO-851: FlashScan IntelliQuad PLUS Adva�ced Multi-Crite- ENCLOSURES, CHASS/S,AND DRESS PLATES <br /> ria Fire/CO Detector See DN-60689 <br /> FSI-851: Low-profile FlashScan ionization detector See DN- CAB-4 Series Enclosure: NFS2-640 mounts in a standard <br /> 6334. CAB-4 Series enclosure (available in four sizes, "A" through <br /> "D") Backbox and door ordered seperately; requires BP2-4 <br /> FSP-851: Low-profile FlashScan photoelectric detector See battery plate. A trim ring option is available for semi-flush <br /> DN-6935 mounting. See DN-6857 <br /> FSP-851T: FSP-851 pius dual electronic thermistors that add EQ Series Cabinets: EQ series cabinets will house amplifiers, <br /> 135°F (57°C) fixed-temperature thermal sensing. See DN- power supplies, battery chargers and control modules. EQ <br /> 6935. cabinets are available in three sizes, "B"through"D" See DN- <br /> FSP-851 R: FSP-851, remote-test capable. For use with 60229 <br /> DNR(W) See DN-6335 CAB-BM Marine System: Protects equipment in shipboard <br /> FST-851: F1ashScan thermal detector 135°F(57°C) See DN- and waterfront applications. For a fuil list of required and <br /> 6936. optionai equipment,see DN-60688. <br /> FST 851 R: FlashScan thermal detector 135°F (57°C) with CHS-0:Chassis for mounting up to four APS-6Rs. <br /> rate-of-�ise. See DN-6936 CHS-4L: Low-profile four-position Chassis. Mounts two AA-30 <br /> FST 851 H: FlashScan 190°F(88°C) high-temperature thermai amplifiers or one AMG-E and one AA-30 <br /> detector See DN-6936. DP-1 B: Blank dress panei. Provides dead-front panel for <br /> FAPT 851: FlashScan Acclimate Plus low-profile multi-sensor unused tiers,covers DAA2-series or AA-series amplifier. <br /> detector See DN-6337 NFS-LBB: Battery Box (required for batteries larger than 26 <br /> FSL-751: FlashScan VIEW laser photo detector See DN- AH) <br /> 6886. NFS-LBBR: Same as above but red. <br /> DNR: InnovairFlex low-ffow non-relay duct-detector housing CtiS-BH1: Battery chassis; holds two 12.0 AH batteries. <br /> (order FSP-851 R separately) Repiaces FSD-751 PUFSD- Mounts one the{eft side of DAA2 chassis.See DN-7046 <br /> 751 RPL. See DN-60429 CA-1:Chassis,occupies one tier of a CAB-4 Series enclosure. <br /> DNRW: Same as above with NEMA-4 rating, watertight. See TI-,e left side accommodates one DVC and a DVC-KD <br /> DN-60429 (optional), and the right side houses a CMIC-1 microphone <br /> B224RB: Low-profile relay base See DN-60054 and its well(optional). See DN-7045. <br /> B224BI: Isolator base for low-profile detectors. See DN- CA-2:Chassis assembiy,occupies two tiers of a CAB-4 Series <br /> 60054 enclosure.The left side accommodates one DVC mounted on <br /> a half-chassis and one NFS2-640 or NCA-2 mounted on a <br /> B210LP: Low-profile base. Standard U S style Replaces half-chassis. The right side houses a microphone/handset <br /> B710LP See DN-60054 well.The CA-2 assembly includes CMIC-1 microphone.ADDR <br /> B501: European-style,4"(10 16 cm)base. See DN-60054 Series doors with two-tier visibility are available for use with <br /> B20QS: Intelligent programmabie sounder base, capable of the CA-2 configuration. ADDFt-B4, ADDR-C4, ADDR-D4 <br /> producing a variety of tone patterns including ANSI Temporal (below) <br /> 3 Compatible with sychronization protocol See DN-60054 CFFT 1: Chassis to mount firefighters teiephone and one ACS <br /> B2UOSR: Sounder base, Temporal 3 or Continuous tone. See annunciator in a CAB-4 row. Includes TELH-1 firefighters <br /> DN-60054 handset for the DVC, chassis, phone well and mounting hard- <br /> ware.Order DP-CFFT dress panel separately <br /> FMM-1: FlashScan monitor module. See DN-6720.. DP-CFFT: CFFT-1 dress panel. Requires BMP-1 if no ACS <br /> FDM-1: FlashScan dual monitor module. See DN-6720.. annunciator is instalfed. <br /> FZM-1: FfashScan two-wire detector monitor module. See DN- ADDR-B4`: Two-tier-sized door designed for use with the CA- <br /> 672� 2 chassis configuration. ADDR Series doors are similar to <br /> FMM-101: FlashScan miniature monitor module. See DN- CAB-4 Series"DR"doors, but a clear window space exposes <br /> 6720. <br /> Page 6 ot B—DN-7111�G�08/09/2012 <br />