My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-13392
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-13392
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/26/2013 9:38:10 AM
Creation date
12/26/2013 9:38:03 AM
Metadata
Fields
Template:
Building Department
Company Name
SUNRISE PROPERTIES OF ZEPHYRHILLS INC
Building Department - Doc Type
Permit
Permit #
12-13392
Building Department - Name
SUNRISE PROPERTIES OF ZEPHYRHILLS INC
Address
6520 FORT KING RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zephyrhills Fire� Res�ue <br /> 6907 Dairy Road, Zephyrhills, FL 33542 <br /> Fire Chief Bus (813) 780-0041 <br /> Keith Williams Fax (813) 780-0044 "' <br /> 29 August 2012 <br /> Plan Number 12-031 <br /> Project: Sunrise Properties of Zephyrhills, Inc. 6520 Fort King Road, Zephyrhills. <br /> Number of Pages: 1 Page Site Plan, 8 pages- Steel Structure, 17 Page Building Plans <br /> This Officer has reviewed the submitted plans for the build out of Sunrise Pruperties of <br /> Zephyrhills, Inc. 6520 Fort King Road, Zephyrhills. Plans are approved as submitted with <br /> the following conditions: <br /> Construction of Steel Building as submitted (Phase 1): <br /> 1. Approved as submitted. <br /> 2. Relocation of rear wall must allow emergency egress/access, shown on site- <br /> plan/survey. <br /> 3. Lightweight truss signs required, at each end on address side with spacing 100 <br /> feet apart. (FAC 69A-60.0081) <br /> Build-out of individual units (Phase 2) <br /> 1. Emergency Lights are required inside each restroom. <br /> 2. Interior 2-hour fire rated wall shall have fire rated doors with self closures, no <br /> un-protected openings are allowed in rated walls. NFPA 1, (12.7.4.2). <br /> 3. Combination Exit/Emergency lights are permitted. <br /> 4. Certified Fire Extinguisher locations may be field located, cabinets ar wall <br /> mounts are acceptable. <br /> Payment of permit fee indicates acceptance of the requirements of these review <br /> comments. Only Phase 1 fees will be assessed at this time. <br /> Inspections Required: <br /> 1. Final Inspections: both Phase 1 and Phase 2. <br /> 2. Firewall inspections in Phase 2: first layer screw inspection, second layer <br /> screw inspection, mud and tape. <br /> Review and approval of the submitted plans does not relieve the contractor from the <br /> responsibility of correcting any deficiencies noted during inspection. <br /> Respectfully subm'tted on 29 August 2012 by, <br /> �� * <br /> Keith A. Williams, EFO, CFO, CEMSO, MIFireE � <br /> Fire Chief <br /> Fire Safety Inspector, #148104 <br />
The URL can be used to link to this page
Your browser does not support the video tag.