Laserfiche WebLink
FORMS <br /> TABLE 402A <br /> BUILDING COMPONENT PERFORMANCE CRITERIA' INSTALLED VALUES: <br /> U-FeCtof<0.65 <br /> Windows(see Note 2): SHGC=0.30 U-Factor= <br /> %ofCFA<=20% SHGC= ���„y� <br /> S.li hts U-Factor<0.75 %of CFA= <br /> Doors:E�nenor door U•Fac[or U-Factor<0.65 U-Factor= <br /> Floors: Slab-on�grade No requirement • - <br /> ver unconditioned s aces see Note 3 q_�3 R-Value= ��,(�j <br /> Walls-E�A.and Ad�.(see Note 3): <br /> Frame R-13 R-Value= <br /> Mass (see Note 3) �� � <br /> Interior of wall: R-7.8 R-Value= <br /> E�Rerior ot wall: R-8 fl-Value= <br /> Ceilings(ses Notes 3&4) R=30 R-Value= Test report <br /> Reflectance ���� � <br /> 025 Fieflectance= Ytta o <br /> Air tlistributicn system(see Note 4) <br /> Ductwork&air handling unit: <br /> Unconditiorred space Not allowed Location: Test repotl <br /> Conditioned space �-��<���j� Attac ? <br /> Duct R-value FI-value?6 J Ye� <br /> Air leakage Qn Qn<0.03 R-Value= <br /> Qn= <br /> Air conditionin s sfems see Nate 5 SEER=13.0 SEER= � <br /> Heating sys[em <br /> hleat pump(see Note 5) Coolin8� SEER=13.0 SEER= <br /> Heatin9� HSPF=7 7 HSPF= <br /> Gas fumace AFUE 78/ �� (�4 '�� <br /> Oil fumace AFUE- <br /> AFUE 78% AFUE_ <br /> Electric resistance:Nat allowed(ses Note 5) <br /> Water heating system(storage rype) <br /> Ele�;tric(see Note 6): 40 gai:EF=0.92 Gellons= <br /> 50g81:EF=0.90 EF= r p ��,_h/ <br /> Gas fired(sse Note 7): 40 gal:EF=0.59 Gallons= ��1 +'V"y <br /> Ottier(describe): 50 gal:EF=0.58 EF= <br /> (1)Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in order to comply with this code using This method; <br /> othervvise Section 405 compliance must be used. <br /> (2)Windows and doors qualifying as glazed fenestratlon areas must compiy with both the maximum U-Factor and the maximum SHGC(solar Heat Gain Coefficient)criteria <br /> an�have a mabmum total window area equal to or less than 20%of the condidoned floor area(CFA);otherwise Secdon 405 must be used for compliance. <br /> Exception: Additions of 600 square feet(56 m2)or less may have a maximum glass to CFA of 50 percent. <br /> (3)R-values are for insulation material only as applied in accordance with manufacturers'installatlon instrucbons.For mass walls,the"interior of wall"requirement must be <br /> met except if at least 50/,of the R-6 insulation required for the"exterior of wall"is installed euterior of,or integral to,the wall. <br /> (4)Ducts&AHU installed substantially leak free per SeCtion 403.2.2.1.Test by Class 1 BERS rater required. <br /> Exception:Ducts installed onto an ewsting air distribution system as part of an addition or renovation;duct must be R-6 installed per Sec.503.2.7.2. <br /> (5)For all conventional units with capacides greater than 30,000 Btu/hr For other types of equipment,see Tables 503.2.3(1-8). <br /> Exception:The prohibition on electric resistance heat does not apply to additions,renovations and new heating systems installed in existing buildings. <br /> (6)For other electric storage volumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For other natural gas storage volumes,minimum EF=0.67-(0.0019 x volume), <br /> TABLE 4028 MANDATORY REpUIREMENTS <br /> COMPONENTS SECTION RE�UIREMENTS CHECK <br /> To be caulked,gasketed,weatherstripped or othenvise sealed.Recessed lighting IC-rated as meeting ASTM E <br /> Au leaka9e 402.4 283.Windows and doors=0.30 cfm/sq.ft.Testing or visual inspection required.Fireplaces:gasketed doors& � / <br /> outdoor combustion aic �r <br /> Ceilings�knee walls 405.2.1 R-19 space pertnitting. <br /> Programmable thermostat 403.1 1 Where forced-air fumace is primary system,prograr,imeble thermostat is required. �,/ <br /> Air distribution system 4032 Ducts in attics or on roofs insuiated to R-8;other duc[s R-6.Ducts tesled to Q„=0.03 by a Class 1 BERS rater. � <br /> Fieat trap required for vertical pipe risers.Comply with eificiencies in Table 403.4.3.2.Provide switch or cleatly <br /> Water heaters � ` 403.4 marked circuit breaker(electric)or shutoff (gas).Circuladng system pipes insulated to=R-2+accessible manual <br /> OFF switch. <br /> Swimmin Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat <br /> I g pool&spas 403.9 loss except'rf 70%of haet from site-recovered energy.Off/timer swftch required.Gas heaters min(mum thermai <br /> effipenc =78% 8296 after M16/13.Heat um ool heateB minimum COP=4.0. <br /> Sizinp calculadon performed&attached.Minimum efficiencies per Tables 503.2.3.Equipment efficiency ver'rfication <br /> Cooling/heating equipment 403.6 required.Special occasion cooling or heaUng capaciry requires separate system or variable capacity system. <br /> _ Electric heat>10kW must be divided into two or more sta es. <br /> l.ighting equipment 404.1 A1 least 50%of pertnanently installed lighting fixtures shall be high-eNicacy lamps. �J <br /> 2010 FLORIDA BUILDING CODE—ENERGY CONSERVATION C.5 <br />