Laserfiche WebLink
�.=�� �+��;�P��awll�;41��IG t'.osds — � <br /> ��� ��� ����� <br /> � .,k:�t' ��� <br /> P 5 <br /> Total Buildin Summar Loads <br /> �. ��, .�. <br /> „ti,w <br /> ;, .�.a�. <br /> � 2A-m-d:Glazing-Double pane low-e (e =0.60), sliding 114 0 0 6,371 6,371 <br /> glass door, metal frame no break, u-value 0.84, <br /> SHGC 0.61 <br /> I11 D: Door-Wood - Solid Core 21 0 0 254 254 I <br /> 13BA-Oocw:Wall-Block, framing with R-11 in 2 x 4 stud 1161 0 0 2,117 2,117 <br /> cavity, open core, wood studs <br /> 16A-25: Roof/Ceiling-Under Attic with Insulation on Attic 864 0 0 2,462 2,462 I <br /> Floor (also use for Knee Walls and Partition Ceilings), <br /> ' Unvented Attic, No Radiant Barrier, Any Roofing <br /> Material,Any Roof Color, R-25 insulation <br /> CustomFloori: Floor-Over open crawl space or garage, 864 0 0 648 648 <br /> Custom, My first example custom floor <br /> I Subtotals for structure: 0 0 11,852 11,852 <br /> �' People: 3 600 690 1,290 <br /> Equipment: 0 1,200 1,200 <br /> i Lighting: 100 341 341 <br /> I Ductwork: 0 732 2,986 3,719 <br /> Infiltration:Winter CFM:0, Summer CFM: 0 0 0 0 0 <br /> Ventilation:Winter CFM:0, Summer CFM: 100 0 3,154 2,198 5,352 <br /> Total Building Load Totals: 0 4,486 19,268 23,754 <br /> � . . .. <br /> _.. . .. _ _.. <br /> _ , <br /> . .�r: ,.. y� .t:#° - �- � }. <br /> . , <br /> ��... :s�:�.�F'?�r ':��-,L,..'�'v .. ':�, ._. :�, . .,Rx.;• ""4Pa�.'-�;.'. �-�s x„ <br /> #� :�y','.�.. .4'�;�.. �fi�:.t, �w`�ti,: i�,�n.�' "'3Y`.;'"'�`%.�':a��~�.�.�i .'i,{.�'"�i i.. ��,';'�,-*r,; <br /> Total Building Supply CFM: 776 CFM Per Square ft.: ✓ p,ggg i* <br /> � Square ft. of Room Area: 864 Square ft. Per Ton: 436 <br /> Volume (ft3) of Cond. Space: (clg.) 7,776 � <br /> * Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area. <br /> � - � . .,����`�;`�,x:. ��� � „,�..�a� �� ,� <br /> y�.> s <br /> ITotal Sensible Gain: 19,268 Btuh� � g1� %o� ,�6 <br /> Total Latent Gain: 4,486 Btuh 19 % <br /> Total Cooling Required Including Ventilation Air: 23,754 Btuh 1.98 Tons(Based On Sensible + Latent) , <br /> � . . , .- - . ... :,�. ..m;�;y�,. �,,y^, .t„ ;����; ;�_.���:� - I <br /> �?s:..k 'Y+", , ' �+�s �,.�.A'�'�� M1`x����';�•x Y�'`S;"-'�1'`'�'tr,gR $ F#�`tR_��-;P <br /> i Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at I <br /> your design conditions. I <br /> � � <br /> i <br /> � <br /> I <br /> � <br /> � I <br /> C:\UsersWaosn\Desktop\ELITE\ChrisTroy.rhv Wednesday, October 10, 2012, 1:19 PM <br />