<br /> S stem 1, Zone 1 Summary Loads (Avera e Load Procedure for Rooms)
<br /> 2A-m-d:Glazing-Double pane low-e (e= 0.60), sliding 114 0 0 6,371 6,371
<br /> glass door, metal frame no break, u-value 0.84,
<br /> SHGC 0.61
<br /> 11 D: Door-Wood - Solid Core 21 0 0 254 254 �
<br /> j 13BA-Oocw:Wall-Block,framing with R-11 in 2 x 4 stud 1161 0 0 2,117 2,117
<br /> cavity, open core,wood studs
<br /> 16A-25: Roof/Ceiling-Under Attic with Insulation on Attic 864 0 0 2,462 2,462 j
<br /> Floor (also use for Knee Walls and Partition Ceilings), �
<br /> Unvented Attic, No Radiant Barrier, Any Roofing
<br /> Material,Any Roof Color, R-25 insulation
<br /> CustomFloorl: Floor-Over open crawl space or garage, 864 0 0 648 648
<br /> Custom, My first example custom floor
<br /> I Subtotals for structure: 0 0 11,852 11,852
<br /> ' People: 3 600 690 1,290
<br /> � Equipment: 0 1,200 1,200
<br /> I Lighting: 100 341 341 �
<br /> I Ductwork: 0 0 2,986 2,986
<br /> Infiltration:Winter CFM:0, Summer CFM:0 0 0 0 0 I
<br /> � System 1, Zone 1 Load Totals: 0 600 17,069 17,669
<br /> „�. ..., . .._ �
<br /> Supply CFM: " 3 �"-t�'��'�,�.: -:.,.., ��; �: ��i:�°.�_�%;,k�:-��_�� q��:f��:.�. �,r,
<br /> ' �',d,
<br /> 776 CFM Per Square ft.: � p.ggg * I
<br /> ISquare ft. of Room Area: 864 Square ft. Per Ton: 587
<br /> Volume (ft3) of Cond. Space: (clg.) 7,776
<br /> " Based on area of rooms being heated or cooled (whichever governs system) rather than entire floor area.
<br /> I =,;;;, ��. ,;;b:.,. _ „�;...
<br /> . �. .-. . .,; . :�
<br /> ����:' „ :�..�`;�. ,�;�_ . ., ,,�._.
<br /> �., :�-,�. ;�
<br /> Total Sensible Gain: 17,069 Btuh g7 %
<br /> Total Latent Gain: 600 Btuh 3 %
<br /> Total Cooling Required: 17,669 Btuh
<br /> 1.47 Tons (Based On Sensible+ Latent)
<br /> . . , :�. . . .:.''.7P��.k"��'t`ffi;�'•;� µ�.!n�`,�t�.'��'rs�,h�::wix";'!��'i:�,�;G';'�;";',:,,',.�°.�sa"' �_�'.yw..-! :r,�a�,'�.��y� a.,� �r_
<br /> 4� ., .a, ; SL�Y'.. "ai'. .z `:_,:Sx�fi�1'�w-eY•�.-X .
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary. i
<br /> I Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.