My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-13993
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-13993
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2014 8:41:03 AM
Creation date
3/24/2014 8:41:00 AM
Metadata
Fields
Template:
Building Department
Company Name
CROWN CASTLE GT COMPANY LLC
Building Department - Doc Type
Permit
Permit #
13-13993
Building Department - Name
CROWN CASTLE GT COMPANY LLC
Address
38522 A AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
j , s <br /> Date October 24,2012 OO ��O�TM <br /> Shelia Turnipseed SSOE Group <br /> Crown Castle 1001 Madison Ave. <br /> 197 Charmant Place, Suite 2 Toledo, OH 43604 <br /> Ridgeland, MS 39157 (419)255-3830 <br /> (601)607-3504 bniese@ssoe.com <br /> Subject: Structural Analysis Report <br /> Carrier Designation: Verizon Wireless Co-Locate <br /> Carrier Site Number: 89059 <br /> Carrier Site Name: CROWN ZEPHYRHILLS <br /> Crown Cast/e Designation: Crown Castle BU Number: 816298 <br /> Crown Castle Site Name: ZEPHYRHILLS <br /> Crown Castle JDE Job Number: 207227 <br /> Crown Castle Work Order Number: 541052 <br /> Crown Castle Application Number: 165308 Rev. 1 <br /> Engineering Firm Designafion: SSOE Group Project Number: 012-01232-00 <br /> Site Data: 702 B Avenue,Zephyr Hills, FL 33542, Pasco Courrty <br /> Latitude 28°13'40.63'; Longitude-82°10'45.6" <br /> 285 Foot—Modified Self Support Tower <br /> Dear Ms. Shelia Turnipseed <br /> SSOE Group is pleased to submit this"Structural Analysis Report"to determine the structural integrity of the above <br /> mentioned tower This analysis has been performed in accordance with the Crown Castle Structural `Statement of <br /> Wor1c' and the terms of Crown Castle Purchase Order Number 497522, in accordance with application 165308, <br /> revision 1 <br /> The purpose of the analysis is to determine acceptability of the tower stress level. Based on our analysis we have <br /> determined the tower stress level for the structure and foundation, under the following load case,to be: <br /> LC7 Existing+Reserved+Proposed Equipment Sufficient Capacity <br /> Note.See Table I and Table II for the proposed and existing/reserved loading,respectively <br /> The analysis has been performed in accordance with the 2010 Florida Building Code based upon and ultimate 3- <br /> second gust wind speed of 140 mph converted to a nominal 3-second gust wind speed of 108 mph per section <br /> 1609.3 1 as required for the use in the TIA-222-G Standard per Exception#5 of Section 1609.1 1 Exposure Category <br /> C and Risk Category II were used in this analysis. <br /> We at SSOE Group appreciate the opportunity of providing our continuing professional services to you and Crown <br /> Castle If you have any questions or need further assistance on this or any other projects please give us a call. <br /> Structural analysis prepared by• Benjamin Niese, EI <br /> By signing below, the engineer certifies that they are in Responsible Charge��WI� p��rt as depicted in the <br /> Table of Contents, including attachments and additional calculations. ���� JV�R/ '�+i <br /> �....... <br /> �� �•����B p ���'•��R�► <br /> Respectfully submitted by� `����. �,� e� ���� <br /> ��' No. 81544 ;�� <br /> . <br /> Larry J. Griffdh, P.E � <br /> SeniorStructuralEngineer ° � � /r '�A� <br /> � � , �`:�: <br /> oO: S TB �• � <br /> °,�': . �ssoe <br /> making clients suctessful by saving them time, trouble, and mone�l'v��'��.�� 0 1�O P•' <br /> ��i �' '••..Z •-'�� o <br /> . <br /> ���i����''�`a,:�� <br />
The URL can be used to link to this page
Your browser does not support the video tag.