Laserfiche WebLink
FORM 405-10 <br /> � FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: R0313082 Builder Name: Ryman Construction <br /> Street: Permit Office: City of Zephyrhills <br /> City,State,Zip: Zephyrhills,FL, Permit Number: 1`�0 3 L <br /> Owner. Driftwood Tawnhomes Jurisdiction: 611600 <br /> Design Location: FL,Tampa <br /> 1. New consVuction or existing New(From Plans) 9. Wall Types(2200.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Multi-family a.Concrete Block-Int Insul,Exterior R=10.0 1429.30 ft� <br /> b.Interior Block,Interior R=10.4 413.33 ft <br /> 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 357.33 ft' <br /> 4. Number of Bedrooms 4 d.N!A R= ft= <br /> 10.Ceiling Types (2748.0 sqft.) Insulation Area <br /> 5. Is this a worst case? No a.Cathedral/Single Assembly(Unvented)R=22.0 2748.00 ftZ <br /> 6. Conditioned floor area above grade(ft') 2748 b.N/A R= ft' <br /> c.N/A R= ft' <br /> Conditioned floor area below grade(ft') 0 11.Ducts R �_ <br /> 7. Windows(212.4 sqft.) Description Area a.Sup:2Dining Living,Ret:2Dining Living,AH:Gar 6 150 <br /> a. U-Factor: Dbl,U=0.65 197.40 ft' b.Sup: Dining Living,Ret:Dining Living,AH:Garag 6 150 <br /> SHGC: SHGC=0.35 <br /> b. U-Factor: Sgl,U=0.65 �5.00 ft' 12•Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.35 a.Central Unit 23.4 SEER:13.00 <br /> c. U-Factor: NIA ftZ <br /> b.Central Unit 23.4 SEER:13.00 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft' a.Electric Heat Pump 22.8 HSPF:8.50 <br /> SHGC: b.Electric Heat Pump 22.8 HSPF:8.50 <br /> Area Weighted Average Overhang Depth: 1.333 ft. <br /> Area Weighted Average SHGC: 0.350 14.Hot water systems <br /> a.Electric Cap:40 gallons <br /> 8. FloorTypes (2748.2 sqft.) Insulation Area EF:0.970 <br /> a.Slab-On-Grade Edge Insulation R=0.0 2748.20 ft' b. Conservation features <br /> b.N!A R= ft' None <br /> c.N/A R= ft= 15.Credits None <br /> Glass/Floor Area: 0.077 Total Proposed Modified Loads: 48.65 pASS <br /> Total Standard Reference Loads: 61.22 - <br /> I hereby certify that the plans and specifications covered by Review of the plans and D�T����q� <br /> this calculation are in compliance with the Florida Energy specifications covered by this �+;. r�s Q�, <br /> calculation indicates com liance '�' -�� � <br /> Code. p s3 - :-;�••�� <br /> ���4 with the Florida Energy Code. ti m .?�. ;��=' �°� � <br /> PREPARED BY: Before construction is completed � ,�,�{ ' � <br /> DATE: 03-18-13 this building will be inspected for � " `�� ,s <br /> ��.. <br /> compliance with Section 553.908 * � <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. � <br /> with the Florida Energy,C ���D N''E"�� <br /> t � � <br /> OWNER/AG N BUILDING OFFI �AL• ` <br /> DATE: D DATE: � � <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with 403.2.2.1.1. <br /> - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist <br /> 3/18/2013 2:56 PM EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 7 <br />