Laserfiche WebLink
Florida Building Code Online Page 2 of 5 <br /> Sections from the Code <br /> Product Approval Method Method 1 Option D <br /> Date Submitted li/17/2011 <br /> Date Validated 12/06/2011 <br /> Date Pending FBC Approval 12/13/2011 <br /> Date Approved O1/31/2012 <br /> Date Revised 02/13/2013 <br /> � - - -- -- -- - <br /> Summary of Products <br /> FL# Model,Number or Name Description <br /> 5302.1 Stratford(M600)and Heritage Dwg.IRC-6009-110-11,Thru 9'wide. <br /> (M950) <br /> Limits of Use Installation Instructions <br /> Approved for use in HVHZ: No FL5302 R2 II IRC-6009-110-11 drawina 7-10 j <br /> Approved for use outside HVHZ:Yes sealed.odf <br /> Impact Resistant: No Verified By:TOM SHELMERDINE 0048579 i <br /> Design Pressure: +19.1/-22.6 Created by Independent Third Party. Yes <br /> Other: Design Pressure+19.1/-22.6, Not for use in Evaluation Reports <br /> HVHZ. Glazing option shall not be used in wind-borne F_L5302 R2 AE IRC-6009-110-11 re�ort 7-10 <br /> debris region unless structure is designed as partially sealed.odf <br /> enclosed or door is a re lacement door. Created b Inde endent Third Part :Yes <br /> 5302.2 Stratford(M600)and Heritage Dwg.IRC-6009-100-11,Thru 9'wide. <br /> (M950) <br /> Limits of Use Installation Instructions <br /> Approved for use in HVHZ: No FL5302 R2 II IRC-6009-100-11 drawina 7-10 <br /> Approved for use outside HVNZ:Yes sealed.odf <br /> Impact Resistant: No Verifled By: TOM SHELMERDINE 0048579 <br /> Design Pressure: +15.8/-18.7 Created by Independent Third Party: Yes <br /> Other: Design Pressure+15.8/-18.7,Not for use in Evaluation Reports <br /> HVHZ.Glazing option shall not be used in wind-borne FL5302 R2 AE IRC-6009-100-11 re�ort 7-10 <br /> debris region unless structure is designed as partially sealed.odf � <br /> enclosed or door is a replacement door. Created b Independent Third Part :Yes <br /> 5302.3 Stratford(M600)and Heritage Dwg.IRC-6009-120-15,Thru 9'wide. � <br /> (M950 <br /> Limits of Use Installation Instructions <br /> Approved for use in HVHZ: No FL5302 R2 II IRC-6009-120-15 drawina 7-10 <br /> Approved for use outside HVHZ:Yes sealed.odf <br /> Impact Resistant: No Verified By:TON SHELMERDINE 0048579 <br /> Design Pressure: +22.8/-26.9 Created by Independent Third Party: Yes <br /> Other: Design Pressure+22.8/-26.9, Not for use in Evaluation Reports <br /> HVHZ. Glazing option shall not be used in wind-borne FL5302 R2 AE IRC-6009-120-15 reoort 7-10 <br /> debris region unless structure is designed as partially sealed.odf <br /> enclosed or door is a replacement door. Created by Independent Third Part :Yes <br /> 5302.4 Stretford(M600)and Heritage Dwg.IRC-6009-130-15,Thru 9'wide. <br /> (M950 <br /> Limits of Use Installation Instructions I <br /> Approved for use in HVH2: No FL5302 R2 II IRC-6009-130-15 drawina 7-10 ' <br /> Approved for use outside HVHZ:Yes sealed.odf <br /> Impact Resistant: No Verified By: TOM SHELMERDINE 0048579 <br /> Design Pressure: +26.7/-31.6 Created by Independent Third Party: Yes <br /> Other: Design Pressure+26.7/-31.6, Not for use in Evaluation Reports , <br /> HVHZ. Glazing option shall not be used in wind-borne FL5302 R2 AE IRC-6009-130-15 reoort 7-10 <br /> debris region unless structure is designed as partially sealed.odf <br /> enclosed or door is a re lacement door. Created b Inde endent Third Part : Yes <br /> 5302.5 Stratford(M600)and Heritage Dwg.IRC-6009-140-15,Thru 9'wide. <br /> (M950) � <br /> Limits of Use Installation Instrudions <br /> Approved for use in HVHZ: No FL5302 R2 II IRC-6009-140-15 drawina 7-10 <br /> Approved for use outside HVHZ:Yes sealed.odf <br /> Impact Resistant: No Verified By: TOM SHELMERDINE 0048579 <br /> Design Pressure: +31.0/-35.1 Created by Independent Third Party Yes ! <br /> Other: Desfgn Pressure+31.0/-35.1, Not for use in Evaluation Reports <br /> HVHZ. Glazing option shall not be used in wind-borne FL5302 R2 AE IRC-6009-140-15 reoort 7-10 <br /> http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE VXQwtDqunL7se VZMFL... 4/4/2013 <br />