Laserfiche WebLink
FORM 405-10 � <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Pertormance Method <br /> ProjectName: Rosewood BuilderName: �nd�lsrfles.Ti-�L'evt�ra� �lor,da L(� <br /> Street: �(�13 ,�e t (�,, p� Permit Office: �2�� <br /> City,State,Zip: ,FL, 1 `� ���pU� � <br /> � Permit Number• � O gy <br /> Owner Jurisdiction: <br /> Design Location: FL,Orlando �-- �P� � ��� <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1792.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1344.00 ft' <br /> 3. Number of units,if multiple family � b.Frame-Wood,Adjacent R=11.0 368.00 ft' <br /> c.Frame-Wood,Exterior R=11.0 80.00 ft2 <br /> 4 Number of Bedrooms 3 d.N/A <br /> R= ft= <br /> 5. Is this a worst case? Yes 10.Ceiling Types (2131.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 2059.00 ft2 <br /> 6. Conditioned floor area above grade(ftz) 1842 b.Knee Wall(Vented) R=19.0 72.00 ftZ <br /> Conditioned floor area below grade(ft') 0 c.N/A R= ft' <br /> 11.Ducts R ft' <br /> 7. Windows(229.2 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 461.5 <br /> a. U-Factor• Dbl,U=0.52 229.16 ftz <br /> SHGC: SHGC=0.33 <br /> b. U-Factor• N/A ft= 12.Cooling systems kBtu/hr Efficiency <br /> SHGC• a.Central Unit 34.0 SEER:14.00 <br /> c. U-Factor• N/q n: <br /> SHGC: <br /> 13.Heating systems kBtu/hr Efficienc <br /> d. U-Factor N/A ft' a.Electric Heat Pum y <br /> SHGC� P 34.0 HSPF:8.00 <br /> Area Weighted Average Overhang Depth: 0.823 ft. <br /> Area Weighted Average SHGC: 0.330 14.Hot water systems <br /> 8. Floor Types (1842.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1842.00 ft' EF:0.920 <br /> b.N/A b. Conservation features <br /> R= ft= <br /> c.N/A R_ ftZ None <br /> 15.Credits Pstat <br /> Glass/Floor Area: 0.124 Total Proposed Modified Loads: 31.69 pASS <br /> Total Standard Reference Loads: 42.56 <br /> I hereby certify that the plans and specifications covered by Review of the plans and O,�TiiE ST,��,A <br /> this calculation are in compliance with the Florida Energy specifications covered by this - � <br /> Code. calculation indicates compliance � ��° ?'t;� "�'„� <br /> PREPARED BY: ��1.X1 ��� With the Florida Energy Code. � rr,,f,.. �-•,,;�;_`'�;�.`'� �p <br /> Before construction is completed � ; 't � <br /> DATE: - � _ this building will be inspected for � �a�z �� <br /> compliance with Section 553.908 * * <br /> I hereby certify that this building, as designe ' in compliance Florida Statutes. <br /> with the Florida Ener Code. 1 ' � �C ,�t�'� <br /> OWNER/AGENT: � � BUILDING OFFICIAL: <br /> DATE: DATE: ---�' <br /> - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist <br /> 6/13/2012 12:03 PM EnergyGauge�USA-FlaRes2010 Section 405.4 1 Comptiant Software Pa e 1 of 5 <br /> 9 <br />