My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14082
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14082
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2014 1:29:37 PM
Creation date
3/24/2014 1:29:34 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
13-14082
Building Department - Name
DUNE FL LAND I SUB LLC C/O HAWK
Address
36213 SHADY BLUFF LP LOT 12
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-� wrightsoft° Project Summary Job: Roeswood <br /> Entire House Date: 6/13/2012 <br /> By: GCR <br /> DEL-AIR HEATING & AIR CONDITIONING <br /> 531 CODISCO WAY,SANFORD,FL 32771 phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM <br /> � � � • <br /> For: Inland Homes <br /> FL <br /> Notes: <br /> � - • • • <br /> Weather: Orlando Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db Outside db <br /> Inside db �p � 93 °F <br /> Design TD 28 � Inside db 75 � <br /> Design TD 18 � <br /> Daily range <br /> Relative humidity 50 0�0 <br /> Moisture difference 46 gr/Ib <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 20939 Btuh Structure <br /> Ducts 4165 Btuh Ducts 21309 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent 0 cfm 6021 Btuh <br /> Humidification 0 Btuh Blower � � � Btuh <br /> Piping 0 Btuh 0 Btuh <br /> Equipment�oad 25104 Btuh Use manufacturer's data <br /> Rate/swing multiplier 1.00y <br /> Infiltration Equipment sensible load 27s3o Btuh <br /> Method Simplified <br /> Construction quality Average Latent Cooling Equipment Load Sizing <br /> Fireplaces 0 Structure <br /> Ducts 2663 Btuh <br /> Heatin Coolin Central vent(0 cfm) 1200 Btuh <br /> Area(ft2) 1842 1842 Equipment latent load <br /> Volume(ft3) 15863 15863 3869 Btuh <br /> Air changes/hour 0.38 0.20 Equipment total load <br /> Equiv.AVF(cfm) 100 53 Req.total capacity at 0.75 SHR 3113 0 otn h <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade BASE 13 PURON HP Trade BASE 13 PURON HP <br /> Model 25HBC336(A,W)"30 Cond 25HBC336(A,W)'*30 <br /> AHRI ref no.3698869 Coil FX4DN(B,F)037 <br /> Efficiency 8.2 HSPF AHRI ref no.3698869 <br /> Heating mput Efficiency 12.0 EER, 14.5 SEER <br /> Heatin out ut Sensible cooling 25500 Btuh <br /> 9 P 34026 BFuh @ 47°F Latent cooling 8500 Btuh <br /> Temperature rise Total cooling 34000 Btuh <br /> Actual air flow 1200 cfm Actual air flow <br /> Air flow factor 0.048 cfm/Btuh Air flow factor 1200 cfm <br /> Static pressure 0.30 in H20 0.044 cfm/Btuh <br /> Space thermostat Static pressure 0.30 in H20 <br /> Load sensible heat ratio p,gg <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> ���' wrightsoft" Right-Suite�Universal 2012 12.0.07 RSU08057 2012-Jurr13 15:1327 <br /> .air.local�d\Estimating\FilesUnlandHomes\Rosewood�Rosewood.rup Calc=MJ8 House faces: W Pa9e� <br />
The URL can be used to link to this page
Your browser does not support the video tag.