<br /> Pro"ect Re ort
<br /> �-. .:�-�; �� g �` � ����� .� `
<br /> _ �:' _; R,��: -�
<br /> Project Title: 2082 Vinoy 2008 old 2020
<br /> Designed By: Inland Homes Group
<br /> Project Date: Wednesday, December 06,2006
<br /> Client Name: Inland Homes Group
<br /> Company Name: Nuccio Heating 8�Air Conditioning
<br /> Company Representative: JAC
<br /> Company Address: 6306 Linebaugh Ave
<br /> Company City: Tampa, Florida 33625 -
<br /> Company Phone: 813-961-7895
<br /> Company Fax: 813-962-7895
<br /> Company E-Mail Address: estimating@nuccioac.com
<br /> Company Website: www.nuccioac.com
<br /> g• �.�d,� �Y..,
<br /> Reference City: Tampa, Florida
<br /> Building Orientation: Front door faces Southeast
<br /> Daily Temperature Range: Medium
<br /> Latitude: 28 Degrees
<br /> Elevation: 19 ft.
<br /> Altitude Factor: 0.999
<br /> Outdoor Outdoor Outdoor Indoor Indoor Grains
<br /> �Bulb Wet Bu�4 �LHur�r B�l.1�.,�d01 �Bulb Difference
<br /> Winter: 40 37.52 80% n/a 72 n/a
<br /> Summer: 95 77 45% 50% 75 46
<br /> :.�
<br /> Total Building Supply CFM: 1,396 CFM Per Square ft.: 0.670
<br /> Square ft.of Room Area: 2,082 Square ft. Per Ton: 713
<br /> Volume(ft')of Cond. Space: 22,718
<br /> Total Heating Required Including Ventilation Air: 31,722 Btuh 31.722 MBH
<br /> Total Sensible Gain: 30,688 Btuh 88 %
<br /> Total Latent Gain: 4,361 Btuh 12 %
<br /> Total Cooling Required Including Ventilation Air: 35,049 Btuh 2.92 Tons(Based On Sensible+ Latent)
<br /> .P C4�", "�5..'f
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are pertormed per ACCA Manual J 8th Edition,Version 2,and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacture�'s pertormance data at
<br /> your design conditions.
<br /> \\Nucciosvrlwrightapps ...\IH 2O82 VINOY 2008(2020).rh9 Thursday, January 24, 2013, 8:44 AM