My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14123
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14123
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2014 8:53:17 AM
Creation date
3/25/2014 8:53:15 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
13-14123
Building Department - Name
PIPES,TODD
Address
5740 16TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R W R W Building Consultants, Inc. <br /> B Consulting and Engineering Services for the Building Industry <br /> C P.O Box 230 Valrico,FL 33595 Phone 813.659.9197 <br /> Florida Board of Professional Engineers Certificate of Authori�ation No.9813 <br /> Product <br /> Category Sub Category Manufacturer Product Name <br /> Associated Materials Inc. Model 02A0 <br /> Window Single Hung 3773 State Road Single Hung Window <br /> Cuyahoga Falls,OH 44223 "Non-ImpacY' <br /> Phone 330.922.2108 <br /> Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for <br /> Associated Materials Inc.,based on Rule Chapter No.9N-3, Method 1 D of the State of Florida Product Approval,Dept.of <br /> Community Affairs-Florida Building Commission. <br /> RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named <br /> herein. <br /> Limitafions: <br /> 1 This product has been evaluated and is in compiiance with the 2007/2010 Florida Building Code structural requirements excluding the <br /> "High Velocity Hurricane Zone". <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco. <br /> 3. When used in areas requiring wind borne debris protection,this product is required to be protected with an impact resistant coveri�g <br /> that complies with Section 1609 1.2 of the Florida Building Code. <br /> 4. Site conditions that deviate from the details of drawing FL-10465.6 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 5 See drawing FL-10465.6 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1. Test Report No. Test Standard Testinq Laboratorv Siqned bv <br /> ATI 70677.02-501-47 AAMA/WDMA/CSA 101II.S.2/A440-05 Architectural Testing, Inc. Michael L.Mackereth <br /> 2. Drawinq No. Preaared bv SiQned 8�Sealed bv <br /> No.FL-10465.6 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 3. Calculations Prepared bv Sianed 8�Sealed bv <br /> Product Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> Buck Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 4. Qualitv Assurance <br /> Certificate of Participation issued by Architectural Testing, Inc.,certifying that Associated Materials Inc.is <br /> manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> 11/15/2011 <br /> PF 1362 Sheet 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.