Laserfiche WebLink
FORMS <br /> TABLE 402A <br /> BUILDING COMPONENT PERFORMANCE CRITERIA' INSTALLED VALUES: <br /> U-Factor<0.65 U-Factor= �� <br /> Windows(sae Note 2): SHGC=0.30 SHGC= •3� <br /> %ofCFA<=20% %ofCFA= <br /> S li hts U-Facror<075 _—__ <br /> Doors:Exterior door U-Factor U-Faclor<0 65 U-Factor= <br /> Floors: Slab-on-grade No requiremenl R-Value= <br /> Over unconditioned s aces see Note 3 R-13 <br /> Walls—E#.and Adj.(see Note 3): <br /> Frame R-13 R-Value=I J <br /> Mass (see Note 3) <br /> Interior of wall: R-7.B R-Value= <br /> Exterior of wall: R-6 R-Value= I <br /> Ceilings(see Notes 3 8 4) R=30 R-Value= �� Test report <br /> Attached? <br /> Raflectance 0.25 Reflectance= Yes/ o <br /> Air distribution system(see Note 4) <br /> Ductwork&eir handling unit Location: <br /> Not allowed Test repon <br /> Unconditioned spece Attached? <br /> Conditioned space Yes/� <br /> Duct R-va�ue R-value?6 R-Value=�P <br /> Air leakege Qn Qn 5 0.03 Q�_ <br /> Air conditionin s stems see Note 5 SEER=13 0 SEER= _ <br /> Heating system <br /> Heat pump(see Note 5) Cooling: SEER=13 0 SEER= '� <br /> Heating: HSPF=7 7 HSPF= �� <br /> I <br /> AFUE 78% AFUE= j <br /> AFUE 78% AFUE_ ' <br /> E�acivie-resislence:Not allowed(see Note 5) ' <br /> -—� <br /> Water heating system(storage type) <br /> Electric(see Note 6): 40 gal:EF=0.92 Ga�lons= .4 q2 <br /> 50 gal:EF=0.90 EF= � � I <br /> Gas fired(see Note 7): 40 gal:EF=0.59 Gallons= <br /> 50 gal:EF=0.58 EF= <br /> Other(describe): <br /> (1)Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in orderto comply with this code using this method; <br /> otherwise Section 405 compliance must be used. <br /> (2)Windows and doors qualifying as giazed fenestration areas must comply with both the maximum U-Factor and the maximum SHGC(solarHeat Gain CoeHicient)criteria <br /> and have a maximum totai window area equal to or less than 20%of the conditioned floor area(CFA);otherwise Section 405 must be used for compliance. <br /> Exception: Additions of 600 square feet(56 m2)or less may have a maximum giass to CFA of 50 percent. <br /> (3)R-values are for insulation material only as applied in accordance with manufacturers'installation instructions.For mass walls,the"interiorof wall"requirement must be <br /> met except if at least 50%of the R-6 insulation required for the"exterior of wafl"is installed exterior of,or integral to,the wall. <br /> (4)Ducts 8 AHU installed substantially leak free per Section 403.2.2.1 Test by Class 1 BERS rater required. <br /> Exception:Ducts installed onto an existing air disiribution system as part of an addition or renovation;duct must be R-6 instailed per Sec.503.2.7.2. <br /> (5)For ali conventional units with capacities greater than 30,000 Btu/hr For other types of equipment,see Tables 5032.3(1-8). <br /> Exception:The prohibition on electric resistance heat does not apply to additions,renovations and new heating systems installed in existing buildings. <br /> (6)For other electric storage volumes,minimum EF=0.97-(0.00132 x volume). <br /> (7)For other natural gas storage volumes,minimum EF=0.67-(0.0019 x volume) <br /> TA6LE 4028 MANDATORY REOUIREMENTS <br /> COMPONENTS SECTION RE�UIREMENTS CHECK <br /> To be caulked,gasketed,weathersiripped or otherwise sealed.Recessed lighting IC-rated as meating ASTM E / <br /> Air leakage 402.4 283.Windows and doors=0.30 cfm/sq.k.Testing or visuai inspection required.Fireplaces:gasketed doors& ✓ <br /> outdoor combustion air. — <br /> Ceiiings/knee walls 405.2.1 R-19 space pertnitfing. <br /> Programmable thermostat 403.1 1 Where forced-air fumace is pnmary system,programmable thertnoslat is reqwred. �(,� `� _ <br /> Air distribution system 4032 Ducts in attics or on roofs insulated to R-8;other ducts R-6.Ducts tested to Q,=O.D3 by a Class 1 BERS raler. L/ <br /> Heat trap required for veAical pipe nsers.Comply with afficiencies in Table 403.4.32.Prowde swrtch or cleady <br /> Wa[er heaters 403.4 marked circuit breaker(eleciric)or shutoff (gas).Circulating system pipes insulaled to=Fi-2+accessiWe manual <br /> OFF switch. <br /> Spas and heated pools must have vapor-retardanl covers or a liquid cover or other means proven to reduce heat <br /> Swimming pool&spas 403.9 loss except N 70%ot heat from site-recovered energy.Oflttimer switch required.Gas heaters minimum ihermal <br /> elticien =78% 82%afler 4/16/7 3.Heat um ooI heaters minimum COP=4.0. <br /> Sizing calculalion peAortned&attached,Minimum etficiencies per Tables 5032.3.Equipment efficiency verification <br /> Cooling/heating equipment 403.6 required.Special occasion cooling or heating capacity requires separete system or vanable capacity system. <br /> Electric heat>10kW musl be divided mto two or more sta es. _ <br /> Lighting equipment 404.1 At least 50%of pertnanently installed lighting fixtures shall be high-etticacy lamps. <br /> 2010 FLORIDA BUILDING CODE—ENERGY CONSERVATION C.5 <br />