5953 GALL BLVD Layout <br /> Emg.�exi[IigMs <br /> 30x60 Tent Q <br /> Emg.�exit liglps <br /> � <br /> This site meets the following requirements as set forth in the Florida Fire Prevention Code: <br /> l. Tent is not within 300' of any above ground bulk storage or bulk dispensing areas for flammable <br /> or combustible liquids, flammable gas, or flammable liquefied gas per NFPA ], Section <br /> 65.11.3.12.6(1)through 65.11.3.12.6(3). <br /> 2. No Smoking and No Fireworks Discharge signs placed near the entrances as required by NFPA <br /> 1, Section 65.11.3.11.1, 65.11.3.11.2 and NFPA 1, Section 65.11.4.6.3 respectively. All text will <br /> be in 2" letters, red in color and placed on a white background. <br /> 3. Tent is not within 50' of any motor vehicle dispensing station dispensers(NFPA l, Section <br /> 65.11.3.12.2), above ground storage tanks for flammable or combustible gas, or flammable <br /> liquefied gas,compressed natural gas dispensing station dispensers, or retail propane dispensing <br /> station dispensers per NFPA 1, Section 65.11.3.12.1(1)through . 65.l 1.3.12.1(3). <br /> 4. This tent meets all clearance criterion regarding buildings, combustibles, other tents, stands, <br /> generators(and their applicable fuel storage location),as well as any storage location for <br /> consumer fireworks. Tent parking shall be identified as located not less than ]0' from the tent. <br /> See NFPA 1, Section 65.11.4.9.2.2, Section 65.11.4.9.2.3, and Table 65.]1.4.7.2. <br />