ACCESSIBILITY NOTES: <br />1. THE INTERNATIONAL SYMBOL OF ACCESS381UTY SIGN SHALL BE DISPLAYED AT ALL <br />ACCESSIBLE RESTROOM FACILITIES AND AT ACCESSIBLE BUILDING ENTRANCES UNLESS <br />ALL ENTRANCES ARE ACCESSIBLE. INACCESSIBLE ENTRANCES SHALL HAVE <br />DIRECTIONAL SIGNS INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE. <br />2. ACCESSIBLE DRINKING FOUNTAINS SHAD. HAVE A SPOUT HEIGHT NO HIGHER THAN 36 <br />INCHES ABOVE THE FLOOR AND EDGE OF BASiN NO HIGHER THAN 34 INCHES ABOVE <br />THE FLOOR FOR INDIVIDUALS IN WHEELCHAIRS. ADDITIONALLY, DRINKING WATER PROVISIONS <br />SHALL BE MADE FOR INDIVIDUALS WHO HAVE DIFFICULTY BENDING. <br />3. WHERE STORAGE FACILITIES SUCH AS CABINETS SHELVES, CLOSETS AND DRAWERS ARE <br />PROVIDED AT LEAST ONE TYPE PROVIDED SHALL CONTAIN STORAGE SPACE COMPLYING <br />NTH THE FOLLOWING: DOORS ETC, TO SUCH SPACES SHALL BE ACCESSIM (I.E. TOUCH <br />LATCHES U- SHAPED PULLS} SPACES SHALL BE 15 INCHES MINIMUM AND 48 INCHES <br />MAXIMUM ABOVE THE FLOOR FOR FORWARD REACH R SIDE REACH; CLOTHES RODS R <br />COAT HOOKS SHALL BE A MAXIMUM OF 48 INCHES ABOVE THE FLOOR 46 INCHES MAXIMUM <br />WHEN DISTANCE FROM WHEEL CHAIR TO ROD EXCEEDS 10 INCHES). SHELVES IN KITCHENS <br />R TOILET ROOMS SHALL BE 40 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE IN FLOOR. <br />4. CONTROLS, DISPENSERS, RECEPTACLES AND OTHER OPERABLE EQUIPMENT SHALL BE NO <br />HIGHER THAN 48 INCHES ABOVE THE FLOOR. RECEPTACLES ON WALLS SHALL BE MOUNTED <br />NO LESS THAN 15 INCHES ABOVE THE FLOOR. EXCEPTION; HEIGHT LIMITATIONS DO NOT <br />APPLY WHERE THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE OR WHERE ELECTRICAL <br />RECEPTACLES ARE NOT NORMALLY INTENDED FOR USE BY BUILDING OCCUPANTS. <br />5. WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, THEY SHALL INCLUDE BOTH AUDIBLE <br />AND VISUAL ALARMS. THE VISUAL ALARMS SHALL BE LOCATED THROUGHOUT, INCLUDING <br />RESTROOM, AND PLACED 80 INCHES ABOVE THE FLOOR R 6 INCHES BELOW CEIUNG,WHICH- <br />EVER IS LOWER. <br />6. ALL DOORS SHALL BE OPENABLE BY A SINGLE EFFORT. DOOR CLOSERS SHALL BE ADJUSTED <br />SO THAT FROM AN OPEN POSITION OF 90 DEGREES THE TIME REQUIRED TO MOVE THE DOOR <br />TO AN OPEN POSITION OF 12 DEGREES SHAD. BE 5 SECONDS MINIMUM. THE MAXIMUM FORCE <br />REQUIRED FOR PUSHING R PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL NOT <br />EXCEED 5 LBS. FOR ALL SUDING, FOLDING AND INTERIOR HINGED DOORS. <br />7. FLOOR SURFACES SHALL BE STABLE. FIRM, AND SUP - RESISTANT. CHANCES IN LEVEL BET- <br />WEEN 0.25 INCH AND 0.5 INCH SHALL BE BEVELED PITH A SLOPE NO GREATER THAN 1:2 <br />CHANGES IN LEVEL GREATER THAN 0.S INCH REQUIRE RAMPS. CARPET PILE THICKNESS SHALL <br />BE 0.5 MAX. GRATINGS IN FLOOR SHALL HAVE SPACES NO GREATER THAN 0.5 INCH WOE IN <br />ONE DIRECTION. DOORWAY THRESHOLDS SHALL NOT EXCEED 0.5 INCH IN HEIGHT. <br />8. ACCESSIBLE WATER CLOSETS SHALL BE 17 INCHES TO 19 INCHES, MEASURED FROM THE <br />FLOOR TO THE TOP OF THE SEAT. GRAB BARS SHALL BE 36 INCHES LONG MINIMUM <br />WHEN LOCATED BEHIND WATER CLOSET AND 42 INCHES MINIMUM WHEN LOCATED ALONG <br />SIDE OF WATER CLOSET, AND SHALL BE MOUNTED 33 INCHES TO 38 INCHES ABOVE THE <br />FLOOR. IN ADDITION, A VERTICAL GRAB BAR 18 INCHES MINIMUM IN LENGTH SHALL BE <br />MOUNTED ON THE SIDEWALL WITH THE BOTTOM OF THE BAR LOCATED BETWEEN 39 AND 41 <br />INCHES ABOVE THE FLOOR. AND NTH THE CENTER LINE OF THE BAR LOCATED BETWEEN 39 <br />INCHES AND 41 INCHES FROM THE REAR WALL <br />9. ACCESSIBLE URINALS SHALL BE STALL-TYPE R WALL HUNG WITH ELONGATED RIMS AT A <br />MAXIMUM OF 17 INCHES ABOVE THE FLOOR. <br />10. ACCESSIBLE LAVATORIES AND SiNKS SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34 <br />INCHES ABOVE THE FLOOR. KNEE CLEARANCE OF AT LEAST 27 INCHES HIGH MUST BE <br />PROVIDED WITH A MINIMUM DEPTH OF 8 INCHES BENEATH THE FIXTURE, AND 9 INCHES HIGH <br />MINIMUM NTH A MINIMUM DEPTH OF 11 INCHES BENEATH THE FIXTURE. THE KNEE SPACE <br />MUST BE AT LEAST 30 INCHES WADE. <br />11. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE <br />INSULATED R OTHERVASE CONFIGURED TO PROTECT AGAINST CONTACT. INSULATION R <br />PROTECTION MATERIALS MAY BE SITE INSTALLED. THERE SHALL BE NO SHARP OR ABRASIVE <br />SURFACES UNDER ACCESSIBLE LAVATORIES AND SINKS. <br />12. ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS (I.E. LEVER- OPERATED, <br />PUSH TYPE. ELECTRONICALLY CONTROLLED). <br />13. MIRRORS LOCATED ABOVE LAVATORIES, SINKS R COUNTERS SHALL BE MOUNTED WITCH THE <br />BOTTOM EDGE OF THE REFLECTING SURFACE A MAXIMUM OF 40 INCHES ABOVE THE FLOOR. <br />OTHER MIRRORS IN TOILET ROOMS SHALL BE MOUNTED NTH THE BOTTOM EDGE OF THE <br />REFLECTING SURFACE 35 INCHES MA)GMUM ABOVE THE FLOOR. <br />14. GRAB BARS HAVING A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 1.25 <br />INCHES MiNIMUM AND 2.0 INCHES MAXIMUM. THE SPACE BETWEEN THE GRAB BAR AND THE <br />WALL SHALL BE 1.5 INCHES. <br />15. WATER CLOSET FLUSH CONTROL SHALL BE INSTALLED A MAXIMUM OF 38 INCHES ABOVE THE <br />FLOOR AND SHALL BE LOCATED ON THE OPEN SiDE OF THE WATER CLOSET. <br />16. DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE I.E. LEVER - <br />OPERATED, PUSHTYPE. U- SHAPED) MOUNTED MATH OPERABLE PARTS BETWEEN 34 INCHES <br />MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FLOOR. <br />17. TOILET STALL DOORS SHALL BE THE SELF- CLOSING TYPE <br />18. A TOWEL DISPENSER SHALL BE LOCATED ADJACENT TO ALL ACCESSIBLE LAVATORIES. <br />WILDING DESIGN PARAMETERS <br />1. USE /OCCUPANCY; BUSINESS <br />2. CONSTRUCTION TYPE: VB <br />3. SPRINKLER SYSTEM: NO <br />4. BUILDING AREA: 1,307 S.F. <br />5. BUILDING HEIGHT- S 15 FEET <br />6. NUMBER OF STORIES: i <br />7. NUMBER OF MODULES: 2 <br />0. OCCUPANT LOAD JA_ BASED ON 1QQ- SF/PERSON <br />9. EXTERIOR WALL FIRE RAiTNG: NOT RATED <br />10. THIS BUILDING MUST BE INSTALLED NTH THE FIRE <br />SEPARATION DISTANCES REQUIRED BY FBC TABLE 602 <br />AND SECTION 704.3, <br />11. ENERGY CODE COMPLIANCE: SEE ATTACHED ENERGY <br />CALCULAiIONS. <br />12. MANUFACTURERS DATA PLATE. STATE LABELS ANO <br />3RD PARTY LABELS ARE TO BE LOCATED ADJACENT TO <br />ELECTRICAL PANEL <br />GENERAL NOTES: <br />1. ACCESS TO BUILDING FOR PERSONS IN WHEELCHAIRS IS DESIGNED BY AND FIELD BUILT <br />BY OTHERS AND SUBJECT TO LOCAL JURISDICTION APPROVAL. THE PRIMARY ENTRANCE <br />MUST BE ACCESSIBLE. <br />2. ALL DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A <br />KEY, TOOL. SPECIAL KNOWLEDGE R EFFORT. MANUALLY OPERATED FLUSH BOLTS <br />R SURFACE BOLTS SHALL NOT BE USED. <br />3. ALL GLAZING WITHIN A 24 INCH ARC OF DOORS, WHOSE BOTTOM EDGE IS LESS THAN <br />60 INCHES ABOVE THE FLOOR. AND ALL GLAZING IN DOORS SHALL BE SAFETY, <br />TEMPERED R ACRYLIC PLASTIC SHEET. <br />4. ALL STEEL STRAPS REFERENCED ON FLOOR PLAN SHALL BE 1.5 INCH x 26 GA. NTH <br />8 - 15 GA. x 7/16 INCH CROWN x 1 INCH STAPLES EACH END OF STRAP OR <br />EQUIVALENT FROM RIDGE BEAM TO COLUMN, AND COLUMN TO FLOOR. <br />5. PORTABLE FIRE EXTINGUISHER PER N.F.P.A. - 10 INSTALLED BY OTHERS ON SITE. <br />AND SUBJECT TO LOCAL JURISDICTION. <br />6. PROVISIONS FOR EAT DISCHARGE LIGHTING ARE THE RESPONSIBILITY OF THE <br />BUILDING OWNER AND SUBJECT TO LOCAL JURISDICTION APPROVAL WHEN NOT <br />SHOWN ON THE FLOOR PLAN (INCLUDING EMERGENCY LIGHTING. WHEN REQUIRED). <br />76 WHEN LOW SIDES OF ROOF PROVIDE LESS THAN 6' OF OVERHANG, GUTTERS <br />AND DOWN SPOUTS SHALL BE SITE INSTALLED, DESIGNED BY OTHERS, SUBJECT TO <br />LOCAL JURISDICTION APPROVAL <br />8. WHEN BUILDINGS ARE INSTALLED IN WIND -BORNE REGIONS, EXTERIOR GLAZING SHALL BE <br />IMPACT RESISTANT R PROTECTED NTH AN IMPACT RESISTANT COVERING. UNLESS INDICATED <br />OTHERWISE IN THE SPECIFICATIONS FOR BUILDING, THE GLAZED OPENING PROTECTION WILL <br />BE PROVIDED BY WOOD STRUCTURAL PANELS MATH A MINIMUM THICKNESS OF 7/16' WHICH <br />ARE PRECUT TO COVER THE GLAZED OPENINGS, AND ATTACHED WITH 2 1/2' x j8 WOOD <br />SCREWS SPACED NOT MORE THAN 9' O.C. THE PRECUT WOOD STRUCTURAL PANELS AND <br />WOOD SCREWS ARE TO BE PROVIDED ON SITE BY THE OWNER, SUBJECT TO LOCAL APPROVAL <br />WINO -BORNE DEBRIS REGIONS IN FLORIDA ARE DESIGNATED IN FIGURE 1609 OF 2007 FBC. <br />AND SECTION 1609 OF THE IBC. <br />9. FIRE SAFETY PLAN REVIEW AND INSPECTION IS RESERVED FOR THE LOCAL AUTHORITY <br />HAVING JURISDICTION. <br />10. WINDOWS AND DOORS MUST BE CERTIFIED FOR COMPLIANCE WITH THE WINO DESIGN <br />PRESSURE FOR COMPONENTS AND CLADDING, <br />11. STRUCTURAL DETAILS NOT INCLUDED IN THIS PLAN SET ARE TO BE CONSTRUCTED <br />ACCORDING TO THE MANUFACTURERS STATE APPROVED BUILDING SYSTEM MANUAL <br />12. THIS BUILDING IS NOT DESIGNED TO BE LOCATED IN A HVHZ <br />ATTENTION LOCAL INSPECTIONS DEPARTMENT 1 <br />I SITE INSTALLED ITEMS I <br />THE FOLLOWING ITEMS HAVE NOT BEEN COMPLETED BY THE MANUFACTURER. <br />HAVE NOT BEEN INSPECTED BY RADCO AND ARE NOT CERTIFIED BY THE <br />STATE MODULAR LABEL NOTE THAT THIS UST DOES NOT NECESSARILY <br />UMIT THE ITEMS OF WORK AND MATERIAL THAT MAY BE REQUIRED <br />FOR A COMPLETE INSTALLATION. ALL SITE RELATED ITEMS ARE SUBJECT TO <br />LOCAL JURISDICTION APPROVAL CODE COMPLIANCE MUST BE DETERMINED AT <br />THE LOCAL LEVEL. <br />i. THE COMPLETE FOUNDATION SUPPORT AND TIE DOWN SYSTEM. <br />2. RAMPS, STAIRS AND GENERAL ACCESS TO THE BUILDING. <br />3. PORTABLE FIRE EXTINGUISHER(S). <br />4. DRINKING FOUNTAIN R BOTTLED WATER. BUILDING DRAINS, CIEANOUTS, <br />SERVICE SINK AND HOOK -UP TO PLUMBING SYSTEM. <br />5. ELECTRICAL SERVICE HOOK -UP (INCLUDING FEEDERS) TO <br />THE BUILDING. <br />0. THE MAIN ELECTRICAL PANEL AND SUB- FEEDERS <br />7. CONNECTION OF ELECTRICAL CIRCUITS CROSSING OVER MODULE <br />MATEUNE(S) - (MULTI -UNITS ONLY). <br />8. STRUCTURAL AND AESTHETIC INTERCONNECTIONS BETWEEN MODULES <br />(MULTI -UNITS ONLY). <br />9. EXIT DISCHARGE LIGHTING (INCLUDING EMERGENCY) <br />10. WINDOW AND DOOR HIGH NANO STORM COVERINGS (PER CODE) <br />REFER TO GENERAL NOTES 3, 8 A: 10. <br />11. RESIDENTIAL TYPE STOVE HOOD. <br />12. DOORS AT MATEUNE <br />APPROVED PRODUCTS LiST <br />CATEGORY <br />SUB CATEGORY <br />MANUFACTURER <br />FL APPROVAL NUMBER <br />USED <br />ROOFING <br />SINGLE PLY EPOM <br />MULEHIOE <br />FL 10703.1 <br />EXT. WALLS <br />WINDOWS <br />SINGLE HUNG <br />ATRIUM <br />FL 11828.8 <br />FLORIDA <br />WINDOWS <br />HORIZONTAL SUDE <br />ATRIUM <br />FL 11624.2 <br />FBC CHAPTER 11 <br />�• <br />EXT. DOORS <br />SWINGING EXT. <br />YKK AP <br />FL 5851 R -2 <br />2009 SUPPLEMENTS <br />W/2009 SUPP. <br />EXT. DOORS <br />SYANGING EXT. <br />CECO <br />FL 4553.1 <br />PANEL WALLS <br />SIDING <br />JAMES HARDIE <br />F. 13223 <br />�. <br />PANEL. WALLS <br />SIDING <br />AMERWAX <br />SOR11S 10 'ANA-140f <br />STANLTARDS FOR fLI1LRIU11 51)iIG <br />SOFIA. M10 FASCIA <br />ELECTRICAL NOTES: <br />1, ALL CIRCUITS AND EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE NTH THE <br />APPROPRIATE ARTICLES OF THE NATIONAL ELECTRICAL CODE (NEC). <br />2. WHEN LIGHT FIXTURES ARE INSTALLED IN CLOSETS THEY SHALL BE SURFACE <br />MOUNTED OR RECESSED. INCANDESCENT FIXTURES SHALL HAVE COMPLETELY <br />ENCLOSED LAMPS. SURFACE MOUNTED INCANDESCENT FIXTURES SHALL HAVE <br />A MINIMUM CLEARANCE OF 12 INCHES AND ALL OTHER FIXTURES SHALL HAVE <br />A MINIMUM CLEARANCE OF 6 INCHES FROM 'STORAGE AREA' AS DEFINED BY <br />NEC 410-8(o). <br />3. WHEN WATER HEATERS ARE INSTALLED THEY SHALL BE PROVIDED NTH READILY <br />ACCESSIBLE DISCONNECTS ADJACENT TO THE WATER HEATERS SERVED. THE <br />BRANCH CIRCUIT SNATCH R CIRCUIT BREAKER SHALL BE PERMITTED TO SERVE <br />AS THE ,DISCONNECTING MEANS ONLY WHERE THE SNATCH R CIRCUIT BREAKER <br />IS WITHIN SIGHT FROM THE WATER HEATER R IS CAPABLE OF BEING LOCKED <br />IN THE OPEN POSITION. <br />4, HVAC EQUIPMENT SHALL BE PROVIDED NTH READILY ACCESSIBLE DISCONNECTS <br />ADJACENT TO THE EQUIPMENT SERVED. A UNIT SWITCH NTH A MARKED 'OFF" <br />POSITION THAT IS A PART OF THE HVAC EQUIPMENT AND DISCONNECTS ALL <br />UNGROUNDED CONDUCTORS SHALL BE PERMITTED AS THE DISCONNECTING <br />MEANS WHERE OTHER DISCONNECTING MEANS ARE ALSO PROVIDED BY A <br />READILY ACCESSIBLE CIRCUIT BREAKER. <br />5. PRIOR TO ENERGIZING THE ELECTRICAL SYSTEM THE INTERRUPTING RATING <br />OF THE MAIN BREAKER MUST BE DESIGNED AND VERIFIED AS BEING IN COMPU- <br />ANCE NTH SECTION 110 -9 OF THE NEC BY LOCAL ELECTRICAL CONSULTANT. <br />S. THE MAIN ELECTRICAL PANEL AND FEEDERS ARE DESIGNED BY OTHERS, SITE <br />INSTALLED AND SUBJECT TO LOCAL JURISDICTION A(PP)ROVAL <br />7. ALL CIRCUITS <br />CONNECTED THOAPPROVED ACMODULE TBLE JUNCTION BOXES,) OR CABLE CONNECTORS. <br />B. ALL PROOF �)AENCLOSURES..T E IN WET INTEGRITY OF NMICHH IS NOT AFFECTED WEN AN <br />ATTACHMENT PLUG CAP IS INSERTED R REMOVED. THE RECEPT ITSELF SHALL ALSO <br />BE LISTED FOR DAMP AND WET LOCATIONS. <br />9. EXTERIOR LIGHTS NOT INTENDED FOR 24 HOUR USE SHALL BE CONNECTED TO A <br />PHOTOCELL R TIMER. <br />(1) Tai 1, PUW2 Y WiTH THE LATEST FBC CHANGE DATED <br />(2) THESE PLANS COMPLY WiTH RULE 98-72 (PRODUCT APPROVAL) <br />(3) THE <br />AGENCY'S OFFICE AS DIRECTED BY DCA. FILE IN THE THIRD PART <br />IFOUNDATION <br />iN ACCORDANCE WiTH THE REQUIREMENTS OF THE FLORIDA D.CA , <br />'HESE BUILDING PLANS DO NOT CONTAIN FOUNDATION SUPPORT AND <br />THE TiE DOWN DETAILS AND SPECIFICATIONS. THE ENGINEER OF THE <br />BUILDING PLANS SHALT. NOT BE HELD RESPONSIBLE OR LIABLE FOR <br />T'fE FOUNDATION DESIGN AND THE CONSEQUENTIAL PERFORMANCE OF <br />SUPERSTRUCTURE'S STRUCTURAL COMPONENTS AND S)YI- AS <br />RLIATiNG THERETO. <br />THESE DRAWINGS ARE PREPARED TO THE REQUIREMENTS <br />OF THE FLORIDA MANUFACTURED BUILDING ACT OF 1979 <br />WITH CURRENT REVISIONS. INFORMATION NOT CONTAINED <br />ON THESE DRAWINGS IS NOT REQUIRED BY THE STATE AND <br />IS INTENTIONALLY OMITTED. ITEMS SUCH AS HANDICAP RAMPS, <br />DECKS, ELECTRICAL RISERS, PLUMBING RISERS, AND <br />FOUNDATION PLANS ARE EXAMPLES OF ITEMS NOT REQUIRED. <br />THE ENGINEER OF RECORD IS ONLY CERTIFYING COMPUANCE <br />WITH THE PORTION OF THIS STRUCTURE THAT IS ACTUALLY <br />MANUFACTURED AT OUR FACILITY. <br />STRUCTURAL LOAD LIMITATIONS <br />FLOOR LIVE LOAD: <br />A. 50 PSF <br />B. 2000 LB. CONCENTRATED LOAD <br />OVER 30 INCH x 30 INCH AREA <br />LOCATED ANYWHERE ON FLOOR <br />ROOF UVE LOAD: <br />A. 20 PSF <br />ROOF SNOW LOAD: <br />A. Pg = 30 PSF GROUND SNOW LOAD <br />B. Pf = 23.1 PSF FLAT ROOF SNOW LOAD <br />C. Ce - 1.1 SNOW EXPOSURE FACTOR <br />D. Is 1.0 SNOW IMPORTANCE FACTOR <br />E. Ct = 1.0 SNOW THERMAL FACTOR <br />FLOOD LOAD: <br />THIS BUILDING IS NOT DESIGNED TO BE <br />LOCATED IN A FLOOD HAZARD AREA. <br />WIND LOAD: <br />A. 140 MPH WIND SPEED <br />B. IW = 1.0 WiND IMPORTANCE FACTOR <br />C. B WIND EXPOSURE CATEGORY <br />D. GCpi = 0.18 INTERNAL PRESSURE COEFFICIENT <br />E. Pr Zone 1- 33.2 psf, Zone 2- 52.9 psf, Zone 3- 89.0 psf <br />F. Pw - Zone 4= 36.7 psf, Zone 5 = 44.0 psf <br />G. THIS BUILDING IS NOT DESIGNED FOR PLACEMENT <br />ON THE UPPER HALF OF A HILL OR ESCARPMENT <br />EXCEEDING 15 FEET IN HEIGHT. <br />CODE SUMMARY: <br />STATE <br />BUILDING <br />ELECTRICAL <br />MECHANICAL <br />PLUMBING <br />ACCESSIBILITY <br />ENERGY <br />FIRE RATING OF <br />2007 FBC W/ <br />EXT. WALLS <br />0 HRS <br />ALLOWABLE NO. <br />FBC <br />FLORIDA <br />2009 SUPP• <br />2008 NEC <br />2007 FMC W/ <br />2007 FPC W <br />FBC CHAPTER 11 <br />CHAPTER 13 <br />2007 FFPC <br />2009 SUPPLEMENTS <br />2009 SUPPLEMENTS <br />W/2009 SUPP. <br />W/2009 SUPP <br />PLUMBING NOTES: <br />I. TOILETS SHALL BE ELONGATED MATH NONABSORBENT OPEN FRONT SEATS. <br />2. REST ROOM WALLS SHALL BE COVERED MATH NONABSORBENT MATERIAL <br />TO A MINIMUM HEIGHT OF 48 INCHES A.F.F. <br />FLOORS SHALL HAVE SMOOTH, HARD, NONABSORBENT SURFACE THAT EXTENDS <br />UPWARD ONTO THE WALLS AT LEAST 6 INCHES. <br />3. THIS UNIT MUST BE CONNECTED TO A PUBLIC WATER SUPPLY AND SEWER SYSTEM <br />IF THESE ARE AVAILABLE <br />4. ALL PLUMBING FIXTURES SHALL HAVE SEPARATE SHUTOFF VALVES. <br />5. WATER HEATER SHALL HAVE SAFETY PAN MATH 1 INCH DRAIN TO EXTERIOR, <br />T do P RELIEF VALVE MATH DRAIN TO EXTERIOR, AND A SHUT OFF VALVE WITHIN <br />3 FEET ON A COLD WATER SUPPLY LINE <br />6. DWV SYSTEM SHALL BE EITHER ABS R PVC - OWV. <br />7. WATER SUPPLY LINES SHALL BE CPVC, R COPPER; AND SHALL BE INSTALLED IN <br />ACCORDANCE WITH THE MANUFACTURERS LIMITATIONS AND INSTRUCTIONS. <br />8. WATER CLOSETS ARE TANK TYPE AND URINALS ARE FLUSH TANK TYPE UNLESS <br />OTHERWISE SPECIFIED. <br />9. BUILDING DRAIN AND CLEANOUTS ARE DESIGNED AND SITE INSTALLED BY OTHERS, <br />SUBJECT TO LOCAL JURISDICTION APPROVAL <br />10. SHOWERS SHALL BE CONTROLLED BY AN APPROVED MIXING VALVE MATH A <br />MAXIMUM WATER OUTLET TEMPERATURE OF 120T (48.8.0). <br />11. THERMAL EXPANSION DEVICE, IF REQUIRED BY WATER HEATER INSTALLED, AND IF <br />NOT SHOWN ON PLUMBING PLAN, IS DESIGNED AND SITE INSTALLED BY OTHERS, <br />SUBJECT TO LOCAL APPROVAL <br />12. WATER PIPES INSTALLED IN A WALL EXPOSED TO THE EXTERIOR SHALL BE LOCATED <br />ON THE HEATED SIDE OF THE WALL INSULATION. WATER PIPING INSTALLED IN AN <br />UNCONDITIONED ATTiC SHALL BE INSULATED WITH AN INSULATION OF R -6.5 MINIMUM. <br />13. PIPING IN UNCONDITIONED SPACES MUST BE PROTECTED NTH INSULATION HAVING A <br />MINIMUM R FACTOR OF 6.5 IN ACCORDANCE MATH SECTION 305.6. <br />THE USE OF THIS BUILDING WITHOUT THE REQUIRED DRINKING FACILITIES <br />AND SERVICE SINK IS SUBJECT TO THE APPROVAL OF THE AUTHORITY <br />HAVING JURISDICTION. <br />MECHANICAL NOTES: <br />1. ALL SUPPLY AIR REGISTERS SHALL BE 10 INCHES x 10 INCHES ADJUSTABLE <br />WITH 10 INCHES x 20 INCHES (INSIDE) OVERHEAD FIBERGLASS <br />DUCT, UNLESS OTHERWISE SPECIFIED. DUCTS IN UNCONDITIONED SPACES SHALL <br />HAVE R -5 MINIMUM INSULATION EXCEPT DUCTS EXPOSED TO VENTILATED ATTICS <br />AND CRAWL SPACES SHALL HAVE R -6.5 INSULATION. <br />2. iNTERVOR DOORS SHALL BE UNDERCUT 1.5 INCHES ABOVE FINISHED FLOOR <br />FOR AIR RETURN ANO /R AS NOTED ON FLOOR PLAN. <br />3. HVAC EQUIPMENT SHALL BE EQUIPPED MATH OUTSIDE FRESH AIR INTAKES <br />PROVIiDiNG 20 CFM FOR EACH OCCUPANT. <br />4. RESTRiOOMI VENT FANS SHALL PROMOE 50 CFid R MORE EXHAUST PER <br />WATER CLOSET OR URINAL <br />Llt;vfi'rtE4 FLA \�T 4 . E EN i ivff_-WEIV <br />'SY ZEIPHYRITILLS F1' iw)L'S I 'E <br />pip-a: be ts: tiffs re of I <br />reVew to as&4t tila Con yL;l :off In C01ITp °( a) ca m( <br />1ica 'e &_9 $;lfety miles. Tins f0'o ,v is room ilitc-colLN <br />t0 be a final N"goval of tr,e sctr Iii t i pl i3. it is ti`:e <br />COIlf1 �r,`tOf'S Sole ( 1�� }sibisity to C1l$u(a that ula pf Ii9 a(E <br />Oxnp;ete Compliancy: v�th :;M 8ppliC& .2 NEPA rail s <br />10,A ordinances. In the event that further examination I <br />site inspection rev=:ais areas of non - compliance, it shat it <br />the Contfactoes sole responsibility, at their sola expells'3 I <br />Ming those areas in Compliance. Re (,ity assumes n+� <br />r 3pOrlsibiiity for t:a Co,itr tor's failure to be in 1:OIIIpti <br />vriGy ' 1�b`e WPA (:Ages tTy1 kx:;j o;► �ai'rr .3. <br />r7; <br />rr� <br />i <br />�'e r <br />KENN <br />�V <br />RtVRMD BY$ <br />MICHAEL. A FREY <br />/i-7.- L._/ %rs r' -,l <br />rtD&WA MODULI, M AN3 &UM 9#El <br />N0. SMP 37 <br />Zq' <br />LISTING AGENCY APPROVAL <br />THESE PRINTS COMPLY WITH THE <br />FLORIDA MANUFACTURED BUILDING <br />ACT OF 1979 CONSTRUCTION CODE <br />AND ADHERE TO THE FOLLOWING <br />CRITERIA <br />CONST. TYPE <br />VB <br />OCCUPANCY <br />Business <br />FLOOR LL <br />50 PSF <br />WIND VELOCITY <br />140 MPH <br />FIRE RATING OF <br />EXT. WALLS <br />0 HRS <br />ALLOWABLE NO. <br />OF FLOORS <br />1 <br />MANUFACTURER <br />T&R <br />PLAN NUMBER TRC- 2456 -'Li <br />APPROVAL DATE 3-19-10- <br />T AND R CUSTOM, INC. <br />P.O. BOX 1079 <br />892 NORTH BROAD STREET <br />" "l6 N, P. E. ELWALLE, GEORGIA 31806 -1079 <br />• • • • •.�' •. Ph: (229)- 937 -2581 <br />. E M1s • <br />r1 ♦i_ <br />•, tyo.38447 •. * , <br />-T Eoo�d:ly; <br />.,o •.• OR•.• Gam. <br />SUBMITTAL #: TRC -2456 U BUSINESS <br />STOCK MODEL <br />DATE: JAN. -04 -2010 <br />DRAWN BY: JMG <br />SCALE: NTS SHEET 111: 1 of 3 <br />DESTINATION : ORLANDO, FLA. <br />