My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-13787
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-13787
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2014 11:20:09 AM
Creation date
3/25/2014 11:16:26 AM
Metadata
Fields
Template:
Building Department
Company Name
LOAN FUNDING SOLUTIONS II LLC
Building Department - Doc Type
Permit
Permit #
13-13787
Building Department - Name
LOAN FUNDING SOLUTIONS II LLC
Address
38130 PRETTY POND RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sprinkler 149r July 12, 2012 <br /> � �' FREEDOM� RESIDENTIAL <br /> ' � ' ' PENDENT SPRINKLER <br /> VK468 (K4.9) <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> _�_ .;f, ...¥ <br /> .}Y...,: "� �5� i x4 .�• � �, , ":.3". <br /> R'€ ^i, <br /> <[���:: ' � ��'� ';��� �-`�'`'' � ",�- `�'�"„`=� <br /> aq.; � <br /> F�:a� �q' ^;. ,s �g <br /> f�� 4 �sv�,,.,�? ��' � '�z�,.::� "/�,%:.f����r <br /> .,,�„'' �.. <br /> cULus Listing Reauire�*+Q�+c• <br /> When using Viking Residential Pendent Sprinkler VK468 for systems designed to NFPA 13D or NFPA 13R, apply thE: listed areas of coverage and <br /> minimum water supply requirements shown in the Approval Chart on page 1490 <br /> For systems desioned to NFPA 13 The number of design sprinklers is to be the four contiguous most hydraulically clemanding sprinklers.The mini- <br /> mum required discharge from each of the four sprinklers is to be the greater of the following: <br /> • The flow rates given in the Approval Chart on data page 1490 for NFPA 13D and NFPAI3R applications for each listed area of coverage,or <br /> • Calculated based on a minimum discharge of 0 1 gpmisq.ft.over the"design area"in accordance with sections 8 5.2.1 or 8 6.2.1.2 of NFPA 13 <br /> • Minimum distance between residential sprinklers.8 ft. (2.4 m) <br /> :E��t14�Cr��l.1NG:.�'3�l1C}E�;:IN�r�'`t, � . <br /> ,. c,�.,irs i�t�f�r'�t�ta����rt u���l��tt�!4c�y�nt��zit�bear�i;.Gef}ir�js�hi��l.xr�r�tat c���tgs c�n�+�. �2 <br /> " - ,F��`er ti�-the.R�r��t�h�.;t�:��c�ea�°af ca�ra�.,'a�`ti�aulic d�sign. <br /> Sprinkler Location:Locate sprinklers on the underside of the beams(not in the bays or pockets formed by the beams) Refer to Figure 6 The vertical <br /> distance from the sprinkler deflector to the bottom of the primary beam must be between 1-1/8 and 1-3/4"(29 to 45 mm; The horizontal distance from <br /> the centerline of the sprinkler to the primary beam cannot be more than 2"(51 mm)(Figure 6) <br /> NOTE:Consult with a structural engineer before drilling beams to allow the installation of sprinkler drops.Where drilling is not permitted,sprinkler posi- <br /> tion requirements allow for the sprinkler drop to be placed adjacent to the primary beam. <br /> Beam Position:Directly attached to the underside of a combustible or non-combustible smooth ceiling of any height. <br /> Beam Size and Shape(Cross sectionj: <br /> • Depth:Maximum 14"(356 mm)for primary beams.Secondary beam depth cannot be greater than the primary beam. <br /> • Width:Unlimited. <br /> • Beam Shape. Rectangular to circular <br /> Beam Types:Combustible or non-combustible,solid surface,solid or hollow core. <br /> Beam Spacing: <br /> A. For primary beams,the distance from the wall to the center of the nearest primary beam must be at least 3'-4"(1.0 m),and not more than one-half <br /> the listed sprinkler spacing.Note:Sprinklers may not be required to be loqted in the first beam nearest the wall.Center-to-center distance between <br /> primary beams is to be a maximum of 20 ft(6.1 m).Refer to Figure 7A. <br /> B. When beam pockets created by the primary beams exceed 20 ft(6.1 m)in length,secondary beams are required as follows(also refer to Figure 7B): <br /> 1 Secondary beam depth must be equal to primary beam depth. <br /> 2.Secondary beams must be placed so that the bays formed by the primary beams do not exceed 20 ft(6.1 m)in length. <br /> C. 1Nhen primary beam spans do not exceed 20 ft(6.1 m),secondary beams(not requiredj may have any distance from wall to nearest secondary beam <br /> and any distance center to center behveen secondary beams.Refer to Figure 7C. <br /> Lintels:Must be present over doorways exiting the compartment.Lintel height must be at least 8"(203 mm),or at least thc:depth of the primary beams, <br /> whichever is greater <br /> Beam and Soffit Arrangements: If a soffit is installed,beams may be arranged within the soffit.The cross section of the soffit may be any size,pro- <br /> vided it does not create an obstruction to water distribution per the obstruction rules of NFPA 13 for residential sprinklers.Where there is a so�t,beam <br /> spacing from the wall is to be measured from the face of the so�t rather than the wall.Refer to Figure 7D NOTE:The sprinkler area of coverage is to <br /> be measured from the wall. <br /> Definitions: <br /> • Primary beams.The main beams that run primarily in one direction. <br /> • Secondary beams:The beams that run perpendicular to the main beams. <br />
The URL can be used to link to this page
Your browser does not support the video tag.