Laserfiche WebLink
November 15, 2012 Sprinkler41c <br /> � MICROFAST�AND <br /> � � � . � MicrofastHP° QUICK <br /> RESPONSE PENDENT <br /> SPRINKLERS <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> . <br /> �.: <br /> ��:-. . .�h: . , _. :�r , <br /> r ,�" ' .,. , ,' �,�''k ,�, <br /> °€.: - <br /> � �° . <�•' - u.~, ,�' �n:'s ��t?„,a<. <br /> e� {a ..��i�. ..°�'� .�„ �a:�` �€�:..��€:,-��as�,�-�¢z;;�����?(-, <br /> Ordinary 135°F(57 °C) ~ 100 °F(38 °C) Orange <br /> Ordinary 155°F(68°C) 100°F(38°C) Red <br /> Intermediate 175°F(79°C) 150°F(65 °C) Yellow <br /> Intermediate 200°F(93°C) 150 °F(65 °C) Green <br /> Hi9h 286 °F(141 °C) 225 °F(107 °C) Blue <br /> Sprinkler Finishes: Brass, Chrome-Enloy�, White Polyester, Black Polyester, Black PTFE, and ENT <br /> Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F <br /> (57 °C). <br /> Footnotes <br /> 'The sprinkler temperature rating is stamped on the deflector <br /> 2 Based on NFPA-13 Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the�Authority Having Jurisdiction. <br /> Refer to specific installation standards. <br /> 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These <br /> tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- <br /> patible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed euterior surfaces <br /> only Note that the spring is exposed on sprinklers with Polyester, PTFE,and ENT coatings. For ENT coated automatic sprinklers,the watenvay is <br /> coated <br /> 1 / � � <br /> � � _— � — � — <br /> � � u �� <br /> S rinkler Wrench �, � � <br /> I 6036W/B�� for \\��� - i <br /> installing recessed � i <br /> pendent sprinklers N i Carefully slide the <br /> ��A 1/2" ratchet is required I vvrench sidewoys <br /> Cnot avnilable �ror, Viking> �i i around the protective <br /> � � cap, ensuring engage- <br /> � r�en t with the sprinkler <br /> �~-� wrench flat>, <br /> �===�__ � <br /> �� �� <br /> � - - - � <br /> Figure 2: Wrench 16036W/B for Recessed Pendent Sprinklers <br />