My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14220
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14220
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/18/2014 1:47:30 PM
Creation date
4/18/2014 1:47:28 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
13-14220
Building Department - Name
FRESINA,ANN L
Address
5930 13TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� R� R W Building Consultants, Inc. <br /> WConsulting and Engineering Services for the Building industry <br /> B P.O Box 230 Vulrico,FL 33595 Phonc 813.659.9197 <br /> cFlorida Board of Professional Engineers Certifica[e of AWhori�a[ion No.9813 <br /> � / � � l <br /> � <br /> Product <br /> Category Sub Category Manufacturer Product Name <br /> Associated Materials Inc. Model 0201 <br /> Window Double Hung 3T73 State Road Extruded Vinyl <br /> Cuyahoga Falis,OH 44223 Double Hung Window <br /> Phone 330.922.2108 "Non-ImpacY' <br /> Scope: Product Evaluation report issued by R W Building Consultants,Inc.8 Lyndon F.Schmidt,P.E.(System ID#1998)for <br /> Associated Materials Inc.,based on Rule Chapter No.9N-3,Method 1 D of the State of Florida Product Approval,Dept.of <br /> Community Affairs-Florida Building Commission. <br /> RW Building Consultants and Lyndon F Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing <br /> or distributing the product or in any other entity involved in the approval process of the product named herein. <br /> Limitatfons: <br /> 1 This product has been evaluated and is in compliance with the 2007/2010 Florida Building Code structural requirements excluding the <br /> "High Velocity Hurricane Zone" <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco <br /> 3 When used in areas requiring wind borne debris protection,this product is required to be protected with an impact resistant covering that <br /> complies with Section 1609.1.2 of the Florida Building Code <br /> 4 Site conditions that deviate from the details of drawing FL-11720.1 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 5 For 2X stud construction,anchoring of the assemblies shall be as shown for 2X buck masonry construction. <br /> 6 See drawing FL-11720 1 for size and design pressure limitations. <br /> Supporiing Documents: <br /> 1 Test Report No. Test Standard Testinp Laboratorv Siqned bv <br /> ATf 97028.02-501-47 AAMA/WDMA/CSA 101/I.S.2/A440-08 Architectural Testing, Inc. Lynn George <br /> 2. Drawinp No. Prepared bv Sipned 8 Sealed bv <br /> No.FL-11720.1 RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, P.E. <br /> 3. Calculations Prepared bv Siqned 8�Sealed bv <br /> Product Anchoring RW Building Consultants, Inc. (CA#9813) Lyndon F Schmidt,P.E. <br /> Buck Anchoring RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 4 Qualitv Assurance <br /> Certificate of Participation issued by Architectural Testing, Inc., certifying that Associated Materials Inc.is <br /> manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. <br /> G�- <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> PF 1273 11l4/2011 <br /> Sheet 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.