Laserfiche WebLink
�.. . , . . . E�s 8oilwr��v�Nop��.lnc. <br /> , , ,.. . ;� �� <br /> Miscellaneous Re ort <br /> " "� €�1c�or � Ic�Oar � � <br /> � 1i�;'� F�:i�t Rei.#� 8�b D� <br /> Winter: 40 37.52 80% n/a 70 n/a <br /> Summer: 95 77 45°/a 50% 75 46.41 <br /> D�t' <br /> Main Trunk Runouts <br /> Calculate: Yes Yes <br /> Use Schedule: Yes Yes <br /> Roughness Factor: 0.00300 0.01000 <br /> Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. <br /> Minimum Velocity: 650 ft./min 450 ft./min <br /> Ma�dmum Velocity: 900 ft./min 750 ft./min <br /> Minimum Height: 8 in. 8 in. <br /> Ma�dmum Height: 8 in, g in, <br /> ,�x. <br /> Win r Summer <br /> Infiltration Specified: 0.000 AC/hr 0.230 AC/hr <br /> 0 CFM 38 CFM <br /> Infiltration Actual: 0.000 AC/hr 0.000 AC/hr <br /> Above Grade Volume: X� Cu.ft. X 10.035 Cu.ft. <br /> 0 Cu.ft./hr 0 Cu.ft./hr <br /> X . 1 7 X 0•0167 <br /> Total Building Infiltration: 0 CFM 0 CFM <br /> Total Building Ventilation: 0 CFM 70 CFM <br /> ---System 1--- <br /> Infiltration&Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference) <br /> Infiltration&Ventilation Latent Gain Multiplier: 31.54 = (0.68 X 0.999 X 46.41 Grains Difference) <br /> Infiltration &Ventilation Sensible Loss Multiplier: 32.98 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) <br /> Winter Infiltration Specified: 0.000 AC/hr(0 CFM),Construction:Average <br /> Summer Infiltration Spec'rfied: 0.230 AC/hr(38 CFM), Construction:Average <br /> �' �7�r 1 <br /> l� twd D�td Stt�fsE�a F�m <br /> A1�r: '� ' �:�n k�ut�ic�t Area (�i <br /> 1 Supply Main Attic 16B 0.12 6 112 No <br /> 1 Return Main Attic 16B 0.24 6 112 No <br /> C:\Users�.laosn\Desktop\ELITE�ACEVEDO.rhv Wednesday,June 26,2013,8:34 AM <br />