�'wf . , , . . '#.ww�s ����wr��A�,y� alw�.
<br /> ��r,� �, �� �.w�waV�
<br /> Total Buildin Summar Loads
<br /> A�ea sen l�t 3en Tt#�
<br /> I � f,�t�ut l� C,e�r+ C3�'t �n
<br /> 1 C-cm:Glazing-Single pane window with storm, clear, 133 0 0 10,272 10,272
<br /> metal frame no break,u-value 0.87,SHGC 0.67
<br /> 11 F: Door-Wood -Solid Core With Metal Storm 21 0 0 182 182
<br /> 13AB-Ofcs:Wall-Block, no blanket or board insulation, 998 0 0 4,090 4,090
<br /> filled core,siding finish
<br /> 16A-19: Roof/Ceiling-Under Attic with Insulation on Attic 1254.4 0 0 4,610 4,610
<br /> Floor(also use for Knee Walls and Partition Ceilings),
<br /> Unvented Attic, No Radiant Barrier,Any Roofing
<br /> Material,Any Roof Color, R-19 insulation
<br /> FLOOR ON SLAB: Floor-Over open crawl space or 1254.4 0 0 621 621
<br /> garage,Custom, FLOOR ON THE SLAB
<br /> Subtotals for structure: 0 0 19,775 19,775
<br /> People: 2 400 460 860
<br /> Equipment: 0 1,200 1,200
<br /> Lighting: 70 239 239
<br /> Ductwork: 0 732 2,998 3,729
<br /> Infiltration:Winter CFM:0,Summer CFM:0 0 0 0 0
<br /> Ventilation:Winter CFM:0, Summer CFM:70 0 2,208 1,539 3,747
<br /> Total Building Load Totals: 0 3,339 26,210 29,550
<br /> f�+`I8� .
<br /> Total Building Supply CFM: 1,122 CFM Per Square ft.: 0.895 *
<br /> Square ft. of Room Area: 1,254 Square ft. Per Ton: 509
<br /> Volume(ft3)of Cond. Space:(clg.) 10,035
<br /> * Based on area of rooms being heated or coofed(whichever governs system) rather than entire floor area.
<br /> Total Sensible Gain: 26,210 Btuh 89 °/a
<br /> Total Latent Gain: 3,339 Btuh 11 %
<br /> Total Cooling Required Including Ventilation Air: 29,550 Btuh 2.46 Tons(Based On Sensible+ Latent)
<br /> NO�
<br /> Rhvac is an ACCA approved Manual J and Manual D computer program.
<br /> Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
<br /> All computed results are estimates as building use and weather may vary.
<br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
<br /> your design conditions.
<br /> C:\UsersWaosn\Desktop\ELITEWCEVEDO.rhv Wednesday,June 26,2013,8:34 AM
<br />
|