My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14332
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14332
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2014 10:11:47 AM
Creation date
4/23/2014 10:11:45 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
13-14332
Building Department - Name
DUNE FL LAND I SUB LLC
Address
36212 SHADY BLUFF LP BLDG 3 LOT 1
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 4b5-10 <br /> Florida Code Compliance Checklist <br /> Florida Department of Business and Professional Regulations <br /> Residential Whole Building Performance Method <br /> ADDRESS: PERMIT#: <br /> TAMPA, FL, 33625- <br /> MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. <br /> COMPONENT �i SECTION SUMMARY OF REQUIREMENT(S) CHECK <br /> Air leakage 'I 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed <br /> � Recessed lighting IC-rated as meeting ASTM E 283. Windows and 'i <br /> ' doors =0.30 cfm/sq ft. Testing or visual inspection required Fireplaces' 'I <br /> I gasketed doors&outdoor combustion air. Must complete envelope <br /> leakage report or visually verify Table 402.4.2 I <br /> Thermostat& , 403 1 At least one thermostat shall be provided for each separate heating and <br /> controls cooling system. Where forced-air furnace is primary system, <br /> �, �I programmable thermostat is required. Heat pumps with supplemental <br /> electric heat must prevent supplemental heat when compressor can I <br /> I meet the load I <br /> Ducts 403.2.2 ' All ducts, air handlers, filter boxes and building cavities which form the � <br /> primary air containment passageways for air distribution systems shall <br /> be considered ducts or plenum chambers, shall be constructed and <br /> � sealed in accordance with Section 503.2.7.2 of this code , <br /> 403 3 3 Building framing cavities shall not be used as supply ducts. <br /> Water heaters , 403 4 Heat trap required for vertical pipe risers. Comply with efficiencies in <br /> �, i Table 403 4.3.2 Provide switch or clearly marked circuit breaker <br /> � (electric)or shutoff(gas). Circulating system pipes insulated to= R-2 'i <br /> � +accessible manual OFF switch. , <br /> Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical <br /> ventilation i ventilation systems shall not exceed the minimum ASHRAE 62 level. <br /> '� I No make-up air from attics, crawlspaces, garages or outdoors adjacent <br /> to pools or spas , <br /> Swimming Pools 403 9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 �, <br /> & Spas HP shall have the capability of operating at two or more speeds. Spas <br /> , and heated pools must have vapor-retardant covers or a liquid cover or <br /> ' other means proven to reduce heat loss except if 70% of heat from <br /> site-recovered energy. Off/timer switch required. Gas heaters minimum ' <br /> i thermal efficiency=78% (82%after 4/16/13) Heat pump pool heaters <br /> minimum COP= 4 0 <br /> Cooling/heating I 403 6 Sizing calculation pertormed &attached. Minimum efficiencies per <br /> � � Tables 503.2.3 Equipment efficiency verification required Special <br /> equipment occasion cooling or heating capacity requires separate system or <br /> variable capacity system Electric heat>10kW must be divided into two <br /> , or more stages � <br /> , <br /> Ceilings/knee walls 405.2.1 R-19 space permitting <br /> 1/24/2013 923 AM EnergyGaugeO USA-FlaRes2010 Section 405.4 1 Compliant Software Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.