13-14332
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14332
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2014 10:11:47 AM
Creation date
4/23/2014 10:11:45 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
13-14332
Building Department - Name
DUNE FL LAND I SUB LLC
Address
36212 SHADY BLUFF LP BLDG 3 LOT 1
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Nuccio Heating and Air 2082 Vinoy 2008 old 2020 <br /> Tampa,F� 33625 Page 2 <br /> Project Report <br /> General Project Information <br /> Project Title 2082 Vinoy 2008 old 2020 <br /> Designed By� Inland Homes Group <br /> Project Date Wednesday, December 06, 2006 <br /> Client Name Inland Homes Group <br /> Company Name Nuccio Heating &Air Conditioning <br /> Company Representative. JAC <br /> Company Address 6306 Linebaugh Ave <br /> Company City: Tampa, Florida 33625 <br /> Company Phone 813-961-7895 <br /> Company Fax: 813-962-7895 <br /> Company E-Mail Address estimating@nuccioac.com <br /> Company Website www.nuccioac.com <br /> Design Data <br /> Reference City� Tampa, Florida <br /> Building Orientation Front door faces Southeast <br /> Daily Temperature Range Medium <br /> Latitude. 28 Degrees <br /> Elevation. 19 ft. <br /> Altitude Factor� 0.999 <br /> Outdoor Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference <br /> Winter 40 37 52 80% n/a 72 n!a <br /> Summer 95 77 45°/a 50% 75 46 <br /> Check Figures <br /> Total Building Supply CFM 1,396 CFM Per Square ft.: 0.670 <br /> Square ft. of Room Area: 2,082 Square ft. Per Ton. 713 <br /> Volume (ft')of Cond Space 22,718 <br /> Building �oads <br /> Total Heating Required Including Ventilation Air: 31,722 Btuh 31 722 MBH <br /> Total Sensible Gain• 30,688 Btuh 88 % <br /> Total Latent Gain 4,361 Btuh 12 % <br /> Total Cooling Required including Ventilation Air: 35,049 Btuh 2 92 Tons (Based On Sensible+ Latent) <br /> Notes <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions <br /> \\Nucciosvr\wrightapps ..11H 2O82 VINOY 2008 (2020) rh9 Thursday, January 24, 2013, 8 44 AM <br />