Laserfiche WebLink
Florida Building Code Online Page 2 of 3 <br /> FL# Model, Number or Name Description <br /> 4904.1 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/5 and O/5 Single Door <br /> Units <br /> Limits of Use Certiffcation Agency Certi�cafe <br /> Approved for use in HVHZ: Yes FL4�04 RS C CAC N1006110.Oi.odf <br /> Approved for use outside HVHZ: Yes Quality Assurance Conlract ExpJration Date <br /> Impact Resistant: Ves 12/31/20i4 <br /> Design Pressure: +76.0/-76.0 Insfallalion Instructions <br /> Other:Evaluated for use in locations adhering to the Florida FL4904 RS 11 FL0128.odf <br /> Building Code including the High Velocity Hurricane Zone, and Verified By:National Accreditation&Management Institute, <br /> where pressure requirements as determined by ASCE 7, Minimum Created by Independen[Third Party: <br /> Design Loads for euildings and Other Structures, does not exceed Eva/uafion Reports <br /> the design pressures listed. 3'-0"x 6'-8"max nominal size. When FL4904 RS AE 504A.ndf <br /> large missile impact resistance is required, hurricane protective Created by Independent Third Party: Yes <br /> system is NOT required. See DWG-MA-FL0128-OS for details. <br /> I 4904.2 Wood-edge Steel Side-Hinged Door 8'-0"Opaque I/S and O/S Single Door <br /> Unrts <br /> �Limits of Use Certification Agency Certfflcate <br /> I Approved for use in HVH2: Yes FL4904 R5 C CAC N1006110.02.adf <br /> Approved for use outside HVHZ: Yes Qualify Assu�ance Contract Expiration Date <br /> Impact Resistanl: Yes 12/31/2014 <br /> Design Pressure: +70,0/-70.0 Installation Insfrucifons <br /> Other:Evaluated for use�n locations adhering to the Florida FL4904 RS II FL0129.odf <br /> Building Code induding the High Velocity Hurricane Zone, and Verified By: Nationa!Accreditatlon&Management Institute, <br /> where pressure requirements as determined by ASCE 7, Minimum Created by Independent Third Party: <br /> Deslgn Loads for Buildings and Other Str�ctures, does not exceed Eva/uation Reports <br /> the design pressures listed. 3'-0"x 8'-0"max nominal size. When FL4904 RS AE 503A.odf <br /> large missile Impact resistance is required, hurricane protective Created by Independent Third Party: Yes <br /> system is NOT re uired. See DWG-MA-FLOi29-OS for details. <br /> 4904 3 Wood-edge Steel Side-Hinged Door 6'-8"Opaque I/S and O/S Door w/or w/o S/delites <br /> Units <br /> Limits of Use CertificaYfon Agency Certificate <br /> I Approved for use in HVH2: Yes FL4904 R5 C CAC N1006i10 01 vdf <br /> 1 Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date <br /> Impact Resistanl: Yes 12/31/2014 <br /> Design Pressure: +55.0/-55.0 Installa[ion Instructions <br /> Other:Evaluated for use in locations adhering to the Florida FL4904 R5 77 FL0128 ndf <br /> Buildrng Code includrng the Hrgh Velocity Hurricane Zone, and Verified By: Nationa/Accreditation&Management Instltute, <br /> where pressure requirements as determined by ASCE 7, Minimum Created by Independent Thrrd Party: <br /> Design Loads for Buildings and Other Structures, does not exceed Eva/uafion Reports <br /> the design pressures listed i2'-0"x 6'-8"max nominal size. When FL4904 RS AE 502A.ndf <br /> Ilarge missile impact resistance is required, hu�ricane protective Created by Independent Third Party: Yes <br /> �system is NOT required on opaque panels, but is required on glazed <br /> �panels. See DWG-MA-FL0128-OS for details. <br /> I <br /> i 4904.4 Wood-edge Steel Side-Hinged Door 8'-0"Opaque 1/5 Doo�w/or w/o Sidelites <br /> i Units <br /> Limits of Use Certification Agency Certificate <br /> Approved for use in HVHZ: Yes FL4904 RS C CAC N1006110.02 odf <br /> Approved for use outside HVHZ: Yes Quality Assu�ance Contract Expiration Date <br /> Impact Resistant: Yes 12/31/2014 <br /> Design Pressure: +45.0/-50 D Installation instructions <br /> Other:Evaluated for use in locations adhering to the Florida FL4904 RS II FLOi29 Ddf <br /> Burlding Code including the High Velocrty Hurrrcane Zone, and Ve�ified By• National Accreditation&Management Institute, <br /> where pressure requirements as determined by ASCE 7, Minimum Created by Independent Third Party: <br /> Design Loads for Buildings and Other Structures, does not exceed Evaluatfon Reports <br /> the design pressures listed. 12'-0"x 8'-0"max nomina!size. When FL4904 RS AE SOlA odf <br /> (large missile impact resistance is required, hurricane protective Created by Independent Third Party: Yes <br /> ;system is NOT required on opaque panels, but is required on glazed <br /> i panels.See DWG-MA-FL0129-OS for details. <br /> �4904.5 Wood-edge Steel Side-Hinged Door 8`-0"Opaque O/S w/or w/o Sidelites <br /> Units <br /> I Limits of Use Certi�cation Agency Certificate <br /> Approved for use in HVHZ: Yes FL4904 RS C CAC N1006110 02 odf <br /> Approved for use outside HVH2; Yes Quality Assu�ance Contratt Expiration Date <br /> Impact Resistant: Yes 12/3i/2014 <br /> IDesign Pressure: +50.0/-45.0 Installation Instructions ( <br /> Other:Evaluated for use in locations adhering to the Florida FL4904 R5 II FL0129 odf <br /> �Building Code including the High Velocity Hurricane Zone, and Verified By National Accreditation&Management Institute, <br /> i where pressu�e requirements as determined by ASCE 7, Minimum Created by Independent Third Party: <br /> Design Loads for Buildings and Other Structures, does not exceed Evaluation Reports <br /> �the design pressures listed. 12'-0"x 8'-0"max nomina/size. When FL4904 RS AE SOIA.odf <br /> large missile impact resistance is required, hurricane protective Created by Independent Third Party: Yes <br /> system is NOT required on opaque panels, but rs required on glazed <br /> panels. See DWG-MA-FL0129-OS for detarls. <br /> http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDateluIwHNbblSc... 6/26/2013 <br />