Laserfiche WebLink
� • � � . � • • � � � <br /> AED Graph <br /> is000 <br /> i0000 <br /> z <br /> m <br /> 0 <br /> J <br /> 5��� <br /> � 8am 9am l0am llam 12pm lpm 2pm 3pm 4pm Spm 6pm 7pm 8pm <br /> — Hourly Loads —Average <br /> � � . • � � <br /> System equipment selection wili be made using the following derived values <br /> Glass (E) 86 sq. ft. <br /> Glass (S) 12 sq. ft. <br /> Glass (N) 12 sq. ft. <br /> Glass (W) 60 sq. ft. <br /> Summer Outdoor 91°F <br /> Summer Wet Bulb 77°F <br /> Summer Indoor 75°F <br /> Summer Design Grains 50% <br /> Winter Outdoor 40°F <br /> Winter Indoor 70°F <br /> Sensible Cooling 21,270 Btuh <br /> Latent Cooling 4,253 Btuh <br /> Required Cooling Airflow 967 CFM <br /> Sensible Heating 17,082 Btuh <br /> Required Heating Airflow 222 CFM <br /> All calculatio�s are based upon approved hvac industry standards and procedures,and comply with all Iocal, <br /> state and federal code requirements.All computed results are Estimates.Product provided by Energy Design <br /> Systems and Idea Tree <br />