Laserfiche WebLink
� � • . � • • � � � <br /> AED Graph <br /> is000 <br /> i0000 <br /> r <br /> 4`+ <br /> J <br /> 51�0� <br /> � <br /> 8am 9am l0am llam 12pm lpm 2pm 3pm 4pm Spm 6pm 7pm 8pm <br /> — Hourly Loads —Average <br /> � � � � � • <br /> Systern equinment selection will be rnade using [he foilowing derived values <br /> Glass (E) 121 sq. ft. <br /> Glass (S) 17 sq. ft. <br /> Glass (N) 17 sq. ft. <br /> Glass (W) 85 sq. ft. <br /> Summer Outdoor 91°F <br /> Summer Wet Bulb 77°F <br /> Summer Indoor 75°F <br /> Summer Design Grains 50% <br /> Winter Outdoor 40°F <br /> Winter Indoor 7p°F <br /> Sensible Cooling 29,041 Btuh <br /> Latent Cooling 5,783 Btuh <br /> Required Cooling Airflow 1,320 CFM <br /> Sensible Heating 24,041 Btuh <br /> Required Heating Airflow 312 CFM <br /> 411 calculations are based upon approved hvac industry standards and procedures,and comply with aIl local, <br /> �tate and federal code requirements All computed results are Estimates.Product provided by Energy Design <br /> Systems and Idea Tree <br />