Laserfiche WebLink
. � � — � � � • • � � � <br /> AED Graph <br /> is000 <br /> i0000 <br /> � <br /> � <br /> � <br /> � <br /> s000 <br /> � 8am 9am l0am llam 12pm lpm 2pm 3pm 4pm Spm 6pm 7pm Spm <br /> — Houriy Loads —Average <br /> � � � � � . <br /> System ec�uipment selection wi11 be made using the following derived values <br /> Glass (E) 113 sq. ft. <br /> Glass (5) 16 sq. ft. <br /> Glass (N) 16 sq. ft. <br /> Glass (W) 79 sq. ft. <br /> Summer Outdoor 91°F <br /> Summer Wet Bulb 77°F <br /> Summer Indoor 75°F <br /> Summer Design Grains 50% <br /> Winter Outdoor 40°F <br /> Winter Indoor 70°F <br /> Sensible Cooling 27,263 Btuh <br /> Latent Cooling 5,432 Btuh <br /> Required Cooling Airflow 1,239 CFM <br /> Sensible Heating 22,215 Btuh <br /> Required Heating Airflow 289 CFM <br /> All calculations are based upon approved hvac industry standards and procedures,and comply with all local, <br /> state and federal code requirements.Ali computed results are Estimates Product provided by Energy Design <br /> Systems and Idea Tree <br />