, . �de���� <br /> .�., <br /> :�,`;�` � . r. �`. <br /> Detailed Room Loads - Room 1 - Ist Floor (Average Load Procedure) <br /> . .I:y;' , , .: , � . <br /> Calculation Mode• Clg. only Occurrences: 1 <br /> Room Length: 42.0 ft. System Number� 1 <br /> Room Width: 27.0 ft. Zone Number: 1 <br /> Area: 1,134.0 sq.ft. Supply Air: 1,327 CFM <br /> Ceiling Height: 8.0 ft. Supply Air Changes: 8.8 AC/hr <br /> Volume: 9,072.0 cu.ft. Req.Vent. Clg: 215 CFM <br /> Number of Registers: 13 Actual Winter Vent.: 0 CFM <br /> Runout Air: 102 CFM Percent of Supply• 0 % <br /> Runout Duct Size: 8 in. Actual Summer Vent.: 215 CFM <br /> Runout Air Velocity: 293 ft./min. Percent of Supply: 16 % <br /> Runout Air Velocity: 293 ft./min Actual Winter Infil.: 0 CFM <br /> Actual Loss: 0.038 in.wg./100 ft. Actual Summer Infil.: 0 CFM <br /> �r� -U- h#� S�en GI� Lat S+�n <br /> V�:+e H'�M Lo�.s HTAA Gain Gair7 <br /> N -Wall-13A6-Ofcs 40 X 8 275 0.183 0.0 0 4.1 0 1,127 <br /> E-Wall-13A6-Ofcs 32 X 8 134 0.183 0 0 0 4.1 0 549 <br /> S-Wall-13A6-Ofcs 40 X 8 320 0.183 0 0 0 4.1 0 1,312 <br /> W-Wall-13A6-Ofcs 32 X 8 226 0.183 0 0 0 4.1 0 926 <br /> N -Door-11 F 3 X 7 21 0.280 0.0 0 8.7 0 182 <br /> N -Gls-1 C-cro shgc-0.67 100%S(2) 24 0.870 0.0 0 31.4 0 754 <br /> E-Gls-1 C-cro shgc-0.67 0%S(2) 50 0.870 0.0 0 81.8 0 4,090 <br /> E-Gls-1 C-cro shgc-0.67 0%S(2) 72 0.870 0.0 0 81.8 0 5,888 <br /> W-Gls-1 C-cro shgc-0.67 0%S 30 0.870 0.0 0 81.8 0 2,453 <br /> UP-Ceil-16A-13 42 X 27 1134 0.070 0.0 0 5.3 0 5,954 <br /> Floor-FLOOR ON SLAB 27 X 42 1134 0 033 0.0 0 0.5 0 561 <br /> Subtotals for Structure. 0 0 23,796 <br /> Infil.:Win.:0.0, Sum.:0.0 1,152 0.000 0 0 000 0 0 <br /> Ductwork: 0 2,996 <br /> People:200 IaUper,230 sen/per: 2 400 460 <br /> Equipment: 0 1,200 <br /> Lighting: 215 733 <br /> Room Totals: 0 400 29,185 <br /> C:\Users\Jaosn\Desktop\ELITEWCEVEDO.rhv Monday,August 26, 2013, 11:53 AM <br />