My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14523
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14523
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2014 9:36:15 AM
Creation date
6/12/2014 9:36:11 AM
Metadata
Fields
Template:
Building Department
Company Name
SUMMERHILL
Building Department - Doc Type
Permit
Permit #
13-14523
Building Department - Name
MORROW-DULIER,MARSHA
Address
5111 SUMMERHILL DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R R W Building Consultants, Inc. <br /> WD Consulting and Engineering Services for the Building Industry <br /> D P.O Box 230 Valrico,FL 33595 Phone 813.659.9197 <br /> C Florida Board uf Professional Engineers Certifica�e of Authorization No.9813 <br /> � , , ► - „ , <br /> ► <br /> Product <br /> Category Sub Category Manufacturer Product Name <br /> Associated Materials Inc. Model 0204 <br /> Window Fixed 3773 State Road PVC Fixed Window <br /> Cuyahoga Fails,OH 44223 "Non-ImpacY' <br /> Phone 330.922.2108 <br /> Scope: Product Evaluation report issued by R W Building Consultants, Inc.&Lyndon F.Schmidt,P.E.(System ID#1998)for <br /> Associated Materials Inc.,based on Rule Chapter No.9N-3, Method 1 D of the State of Florida Product Approval, Dept.of <br /> Community Affairs-Florida Building Commission. <br /> RW Building Consultants and Lyndon F Schmidt,P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named <br /> herein. <br /> Limifations: <br /> 1 This product has been evaluated and is in compliance with the 2007/2010 Florida Building Code structural requirements excluding the <br /> "High Velocity Hurricane Zone" <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco <br /> 3 When used in areas requiring wind borne debris protection,this product is required to be protected with an impact resistant covering <br /> that complies with Section 1609 1.2 of the Florida Building Code. <br /> 4 For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. <br /> 5 Site conditions that deviate from the details of drawing FL-9909.3 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6 See drawing FL-9909 3 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1. Test Reuort No. Test Standard Testinq Laboratorv Siqned bv <br /> ATI 81259.02-501-47 AAMAlWDMA/CSA 101/I.S.2/A440-05 Architectural Testing,Inc. Lynn George <br /> ATI 99583.02-501-47 AAMA/WDMA/CSA 101/I.S.2/A440-08 Architectural Testing,Inc. Lynn George <br /> A4965.�5-501-47 AAMA/WDMA/CSA 101/I.S.2lA440-08 Architectural Testing,Inc. Lynn George <br /> 2. Drawinp No. Prepared bv Siqned&Sealed bv <br /> No FL-9909.3 RW Building Consultants, Inc.(CA#9813) Lyndon F Schmidt, P.E. <br /> 3. Calculations Preaared bv Siqned 8 Sealed bv <br /> Product Anchoring RW Building Consuitants, Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> Buck Anchoring RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt,P.E. <br /> 4 Quality Assurance <br /> Certificate of Participation issued by Architectural Testing, Inc.,certifying that Associated Materials Inc.is <br /> manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53 <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> 11/21/2011 <br /> PF 1295 Sheet 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.