Laserfiche WebLink
R W R W Building Consultants, Inc. <br /> BConsulting and Engineering Services for the Building industry <br /> C P.O Box 230 Valrico,FL 33595 Phone 813.659.9197 <br /> Florida Board of Professional Engineers Ccrtificate of Authorization No.9R 13 <br /> i � i . • <br /> / � <br /> Product <br /> Category Sub Category Manufacturer Product Name <br /> Exterior Sliding Exterior <br /> Aiside Window Company Mode1610516106/6175 <br /> Doors 3773 State Road Extruded Vinyl Siiding Patio Door <br /> Doors Assemblies Cuyahoga Falls,OH 44223 "Non-ImpacY' <br /> Phone 330.922.2108 <br /> Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt, P.E.(System ID# <br /> 1998)for Alside Window Company based on Rule Chapter No.9N-3,Method 1 D of the State of Florida Product Approval, <br /> Department of Community Affairs-Florida Building Commission. <br /> RW Building Consultants and Lyndon F. Schmidt,P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named <br /> herein <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 2007/2010 Florida Building Code(FBC)structural requirements <br /> excluding the"High Velocity Hurricane Zone" <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> orstucco. <br /> 3 When used in areas requiring wind borne debris protection this product is required to be protected with an impact resistant covering <br /> that complies with Section 1609 1.2 of the FBC <br /> 4 For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. <br /> 5. Site conditions that deviate from the details of drawing FL-12320.1 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FL-12320 1 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1 Test Report No. Test Standard Testinq Laboratorv Siqned bv <br /> AI-03158-A2 AAMA/WDMA/CSA 101/I.S.2/A440-05 AIR-INS Inc. Jean Miller,Eng <br /> 2. Drawinq No. Prepared bv Siqned 8�Sealed bv <br /> No. FL-12320.1 RW Building Consultants, Inc.(CA#9813) Lyndon F Schmidt,P.E. <br /> 3. Calculations Prepared bv Signed&Sealed bv <br /> Product Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> Buck Anchoring RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 4. Qualitv Assurance <br /> Certificate of Participation issued by Architectural Testing, Inc.,certifying that Alside Window Company is <br /> manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. <br /> . <br /> �CY— <br /> Lyndon F Schmidt,P.E. <br /> FL PE No.43409 <br /> 2/13/2012 <br /> PF 1457 Sheet 1 of 1 <br />