My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14530
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14530
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2014 9:42:33 AM
Creation date
6/12/2014 9:42:30 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
13-14530
Building Department - Name
SNOKE,JEAN & DIETERICH, PATRICIA
Address
6223 PLEASANT ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�,� .A'ae �•,��y; ""��""��"` .,`""k .. ��r#'•�� _ "n . ^ <br /> ��::-ys.�w`r`�'�.' '�'i � ?. ' ,�i ' �i�,` �`'� <br /> '�-'�',`'�.� a �:� ,t' , � ,fi,,, <br /> Miscellaneous Report <br /> Winter: 40 37.52 80% n/a 70 n/a <br /> Summer: 95 77 45% 50% 75 46.41 <br /> � � ��:;�; �;: <br /> Main Trunk Runouts <br /> Calculate: Yes Yes <br /> � Use Schedule: Yes Yes <br /> Roughness Factor: 0.00300 0.01000 <br /> Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. <br /> Minimum Velocity: 650 ft./min 450 ftJmin li <br /> Maximum Velocity: 900 ft./min 750 ft./min <br /> Minimum Height: 8 in. 8 in. � <br /> Maximum Height: 8 in 8 in. <br /> �: <br /> Winter Summer <br /> I Infiltration Specified� 0.000 AC/hr 0.230 AC/hr <br /> ; 0 CFM 26 CFM <br /> �I Infiltration Actual: 0.000 AC/hr 0.000 AC/hr <br /> I Above Grade Volume. X 0 Cu.ft. X 6.655 Cu.ft. <br /> 0 Cu.ft./hr 0 Cu.ft./hr <br /> X 0.0167 X 0.0167 <br /> �, Total Building Infiltration: 0 CFM 0 CFM <br /> Total Building Ventilation: 0 CFM 90 CFM <br /> ---System 1--- I <br /> Infiltration &Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference) <br /> Infiltration &Ventilation Latent Gain Multiplier: 31.54 = (0.68 X 0.999 X 46.41 Grains Difference) <br /> Infiltration&Ventilation Sensible Loss Multiplier: 32.98 = (1 10 X 0.999 X 30.00 Winter Temp. Difference) <br /> Winter Infiltration Specified: 0.000 AC/hr(0 CFM), Construction:Average <br /> � Summer Infiltration Specified: 0.230 AC/hr(26 CFM), Construction:Average <br /> �5 'o-„ �; <br /> 1 Supply Main Attic 16B 0.12 6 112 No <br /> 1 Return Main Attic 16B 024 6 112 No <br /> I <br /> I <br /> C•\Users\Jaosn\Desktop\ELITEWCEVEDO.rhv Monday, September 09,2013,3:19 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.