Laserfiche WebLink
Florida Building Code Online Page 2 of 4 <br /> Certified By <br /> Sections from the Code <br /> Product Approval Method Method 1 Option D <br /> Date Submitted 06/24/2013 <br /> Date Validated 06/26/2013 <br /> Date Pending FBC Approval 07/O1/2013 <br /> Date Approved 08/23/2013 <br /> Date Revised 08/26/2013 <br /> Summary of Products <br /> FL# Model,Number or Name Description i <br /> 5302.1 Stratford(M600)and Heritage Dwg.IRC-6009-110-11,Thru 9'wide. � <br /> M950 i <br /> Limits of Use Installation Instructions <br /> Approved for use in HVH2: No FL5302 R4 II IRC-6009-110-11 Drewina 7-10 FL odf <br /> Approved for use outside HVHZ:Yes Verified By:TOM SHELMERDINE 0048579 ; <br /> Impact Reslstant: No Created by Independent Third Party•Yes <br /> Design Pressure: +19.1/-22.6 Evaluation Reports <br /> Other: Design Pressure+19 1/-22.6, Not for use in FL5302 R4 AE IRC-6009-110-11 Reoort 7-10 FL odf <br /> HVHZ.Glazing option shall not be used in wind-borne Created by Independent Third Party:Yes � <br /> debris region unless structure is designed as partially i <br /> enclosed or door is a replacement door. <br /> 5302.2 Stratford (M600)and Heritage Dwg.IRC-6009-100-11,Thru 9'wide. <br /> M950 <br /> i <br /> Limits of Use Installation Instructions <br /> Approved for use in HVHZ: No F15302 R4 II IRC-6009-100-i1 drawinQ 7-10 '' <br /> Approved for use outside HVH2:Yes sealed.odf � <br /> Impact Resistant: No Verified By: TOM SHELMERDINE 0048579 ! <br /> Design Pressure: +15.8/-18.7 Created by Independent Third Party: Yes � <br /> Other: Design Pressure+15.8/-18.7,Not for use in Evaluation Reports ! <br /> HVHZ. Glazing option shall not be used in wind-borne FL5302 R4 AE IRC-6009-100-11 reoort 7-10 <br /> debris region unless structure is designed as partially sealed.odf <br /> enclosed or door is a re lacement door. Created b Inde endent Third Part :Yes <br /> 5302.3 Stratford (M600)and Heritage Dwg.IRC-6009-120-15,Thru 9'wide. i <br /> (M950 <br /> Limits of Use Installation Instructions � <br /> Approved for use in HVHZ: No FL5302 R4 II IRC-6009-120-15 Drawina 7-SO FL�df <br /> iApproved for use outside FIVHZ:Yes Verified By:TON SHELMERDINE 0048579 i <br /> Impact Resistant: No Created by Independent Third Party Yes I <br /> Design Pressure: +22.8/-26.9 Evaluation Reports � <br /> Other: Design Pressure+22.8/-26.9, Not for use in FL5302 R4 AE IRC-6009-120-]5 Reoort 7-10 FL pdf <br /> HVHZ. Glazing option shall not be used in wind-borne Created by Independent Third Party: Yes <br /> debris regfon unless structure is designed as partlally <br /> enclosed or door is a replacement door. <br /> 5302.4 Stratford(M600)and Heritage Dwg.IRC-6009-130-15,Thru 9'wide. <br /> M950) i <br /> Limits of Use Installatton Instructions <br /> Approved for use in NVHZ: No FL5302 R4 II IRC-6009-130-15 Drawino 7-10 FL odf <br /> Approved for use outside HVHZ:Yes Verified By:TOM SHELMERDINE 0048579 � <br /> Impact Resistant: No Created by Independent Third Party:Yes <br /> Design Pressure: +26.7/-31.6 Evaluation Reports <br /> Other: Design Pressure+26.7/-31.6, Not for use in FL5302 R4 AE IRC-6009-130-15 Reoort 7-SO FL�df <br /> HVHZ.Glazing option shall not be used in wind-borne Created by Independent Third Party:Yes <br /> debris region unless structure is designed as partially <br /> �enclosed or door is a replacement door. <br /> j 5302.5 Stratford(M600)and Heritage Dwg.IRC-6009-140-15,Thru 9'wide. <br /> (M950) i <br /> i Limits of Use Installation Instructfons i <br /> Approved for use in HVHZ: No FL5302 R4 II IRC-6009-140-15 Drawinq 7-10 FL odf <br /> Approved for use outside HVHZ:Yes Verified By•TOM SHELMERDINE 0048579 � <br /> ; Impact Resistant: No Created by Independent Third Party: Yes <br /> Design Pressure: +31.0/-35.1 Evaluation Reports <br /> I Other: Design Pressure+31.0/-35.1, Not for use in FL5302 R4 AE IRC-6009-140-15 Reoort 7-10 FLOdf <br /> http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGE VXQwtDqunL7seV7.MFL... 9/6/2013 <br />