My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14562
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14562
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2014 10:27:16 AM
Creation date
6/12/2014 10:26:53 AM
Metadata
Fields
Template:
Building Department
Company Name
CITY OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
13-14562
Building Department - Name
CITY OF ZEPHYRHILLS
Address
38122 HENRY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
July 26,20i3 <br /> 190-ft Se/f Support Tower Structura/Modification Ana/ysis CCI BU No 826548 <br /> TEP Project Number 48167.7359,Application 185469, Revisron 4 Page 5 <br /> 3)ANALYSIS PROCEDURE <br /> Table 4- Documents Provided <br /> Document RemarKs Reference Source <br /> �. <br /> - <br /> Geotechnical Report ; Nodarse &Associates, Inc. 3497292 � , CCISites�; <br /> .__..�.___.—___.______�______ <br /> ____.___,..._._. _----- ..�. .�____ <br /> Foundation Drawings ' Valmont Microflect � 3497291 CCISites <br /> _.__. ..__. .._....__.._.. _ __ _._.._.._.. ..-.- ---___._.______.._______....__��_.----___.�.___.. .._._...�.�..._.__..___.�.. ___.:..____._..._.._______.--.----- <br /> Tower Manufacturer Drawings j Valmont Microfiect ; �_ 3675014 � CCISites E <br /> .__.._.._—_.________n---__�__... <br /> �� �..�� <br /> Previous Structural Analysis �Tower Engineering Professionals 3914934 � CCISites � <br /> 3.1) Analysis Method <br /> tnxTower (version 6 0 4.0), a commercially available analysis software package, was used to create a <br /> three-dimensional model of the tower and calculate member stresses for various loading cases <br /> Selected output from the analysis is included in Appendix A. <br /> 3.2) Assumptions <br /> 1) The tower and foundation were built in accordance with the manufacturer's specifications <br /> 2) The tower and foundation have been maintained in accordance with the manufacturer's <br /> specification <br /> 3) The configuration of antennas, transmission cables, mounts and other appurtenances are as <br /> specified in Tables 1 and 2, and"Appendix B–Base Level Drawing". <br /> 4) When applicable, transmission cables are considered as structural components for calculating <br /> wind loads as allowed by the standard. <br /> 5) All tower components are in sufficient condition to carry their full design capacity. <br /> 6) Serviceability with respect to antenna twist, tilt, roll, or lateral translation, is not checked and is <br /> left to the carrier or tower owner to ensure conformance. <br /> 7) All antenna mounts and mounting hardware are structurally sufficient to carry the full design <br /> capacity requirements of appurtenance wind area and weight as provided by the original <br /> manufacturer specifications It is the carrier's responsibility to ensure compliance to the <br /> structural limitations of the existing and/or proposed antenna mounts. TEP did not perform a site <br /> visit to verify the size, condition or capacity of the antenna mounts and did not analyze antennas <br /> supporting mounts as part of this structural analysis report. <br /> 8) The following material grades were assumed. <br /> a) Legs: ASTM A53-B-46 <br /> b) Bracing: ASTM A36 <br /> This analysis may be affected if any assumptions are not valid or have been made in error. Tower <br /> Engineering Professionals should be notified to determine the effect on the structural integrity of the <br /> tower <br /> 4)ANALYSIS RESULTS <br /> Table 5-Section Capacity(Summary) <br /> ���06 Elevation(ft) �Omponent Size Crit[cal P�K� BP���K� % Pass/Fai[ <br /> No. Type Element Capacity <br /> Ti 190-180 Leg P2.5x203 2 15.028 i 53.866 j W27_9 4 Pass <br /> ,. -- _' ---._-----' ---_.. __.._._.___ .._.__�.__._. .._._._._....._...._._ ._.__.._ ..__�-_._..___..__.Y___._..._....-----.r . 1 ..__.__........._. � <br /> T2 180-160 Leg P3.Sx.226 � 20 64.569 , 96.872 66.7 Pass <br /> -----____�---__ _. _�. _ :_— = __ _. <br /> T3 160-140 Leg P5x.258 � 50 ; -128.241 � 157.510 81 4 Pass <br /> : __ _. . - - - --------_ __.. __...___,-- _.. __ _ ---- _._�_�. _.. � <br /> T4 140-120 Leg P8x.322 � 74 -202.020 i 330 771 � 61 1 ; Pass ' <br /> T5 120-113.333 Leg � P8x.322 � 98 ! -226.348 330.771 68.4 � Pass � <br /> I_'_'_'_�_; �' 4 <br /> T6 ��3.333- � Leg PSx.322 � 110 3 -250.973 ' 330 771 75.9 � Pass � <br /> 106.667 , <br /> tnxTower Report-version 6.0 4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.