My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14562
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14562
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2014 10:27:16 AM
Creation date
6/12/2014 10:26:53 AM
Metadata
Fields
Template:
Building Department
Company Name
CITY OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
13-14562
Building Department - Name
CITY OF ZEPHYRHILLS
Address
38122 HENRY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job Page <br /> ������� Pasco County(VS) (BU 826548) 1 of 30 <br /> Project Date <br /> Tower Engineering TEP No. 48167.7359 14:45:23 07/26/13 <br /> Professionals <br /> 3703 Junction Blvd. <br /> Raleigh,NC 27603 Client Designed by <br /> Phone (919)661-6351 Crown Castle ��W <br /> FAX. (919)661-6350 <br /> Tower In ut Data <br /> The main tower is a 3x free standing tower with an overall height of 190.000 ft above the ground line. <br /> The base of the tower is set at an elevation of 0.000 ft above the ground line. <br /> The face width of the tower is 8.000 ft at the top and 21.333 ft at the base. <br /> This tower is designed using the TIA-222-G standard. <br /> The following design criteria apply: <br /> Tower is located in Pasco County,Flonda. <br /> Basic wind speed of 108 mph. <br /> Structure Class II. <br /> Exposure Category C. <br /> Topographic Category 1. <br /> Crest Height 0.000 ft. <br /> Deflections calculated using a wind speed of 60 mph. <br /> Pressures are calculated at each section. <br /> Stress ratio used in tower member design is 1. <br /> Local bending stresses due to climbing loads,feedline supports,and appurtenance mounts are not considered. <br /> Options <br /> Consider Moments-L.egs Distribute L,eg Loads As Uniform Treat Feedline Bundles As Cylinder <br /> Consider Moments-Horizontals Assume L.egs Pinned Use ASCE 10 X-Brace Ly Rules <br /> Consider Moments-Diagonals � Assume Rigid Index Plate � Calcula[e Redundant Bracing Forces <br /> Use Moment Magnifica[ion � Use Cleaz Spans For Wind Area Ignore Redundant Members in FEA <br /> � Use Code Stress Ratios � Use Clear Spans For KI/r SR Leg Bol[s Resist Compression <br /> � Use Code Safety Factors-Guys Reteasion Guys To Initial Tension � All Leg Panels Have Same Allowable <br /> Escalate Ice � Bypass Mast Stability Checks Offset Girt At Foundation <br /> Always Use Max Kz V Use Azimuth Dish Coefficients � Consider Feedline Torque <br /> Use Special Wind Profile v Project Wind Area of Appurt. � Include Angle Block Shear Check <br /> � Include Bolts In Member Capacity Autocalc Torque Arm Areas Po1es <br /> Leg Bolts Are At Top Of Section SR Members Have Cut Ends Include Sheaz-Torsion Interaction <br /> � Secondary Horizontal Braces L.eg V Sort Capacity Reports By Component Always Use Sub-Critical F7ow <br /> Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Use Top Mounted Sockets <br /> Add IBC.6D+W Combination <br />
The URL can be used to link to this page
Your browser does not support the video tag.