Laserfiche WebLink
, <br /> DN•60417:C <br /> F'ireWarden-100-2(E) Rev 2 � N O°I�1 � ' E R^ <br /> Intelligent Addressable FACP � <br /> with Bui�t-�n Communciator by H o n eywe l l <br /> Generai <br /> The Notifier FireWarden-100-2 Fiev 2 (NFW2-100 Rev 2)with <br /> Version 4.0 firmware is a combination FACP (Fire Alarm <br /> Control Panel)and DACT(Digital Alarm CommunicatodTrans- <br /> miiter) all on one circuit board. This compact intelligent <br /> addressable control panel has an extensive lisi of powerful <br /> features. <br /> .�;< ,;L;:c'•.�;.?'-`-'s:i,�;:},r�<a-r•r„s�,o�.,. <br /> ,. v., ..; .l:;t�-'.= "•�,;�`;;� <br /> r , ..::i�,_.??Ll':`;���4itiw;;;. �,. . .� <br /> The SLC(Signaling Line Circuit)of lhe FireWarden-100-2 Rev ;,,,,�;,;g, ,; <br /> .}�'.,:t ,. <br /> 2 operates using a Rapid Group Polling communication proto- �•,:..���� ��'.��±i' <br /> .�,•:_�,� �� >_'+`�, , , <br /> col technology that polls multiple devices simulianeously for a ::''::�.'�::� ��°,�..;; ; <br /> ;iye.�,.:t "'.r <br /> quicker device response time.This patented technology allows :'�c,�+;;7 ,� <br /> :?I'%^:i;fi <br /> a fully-loaded panel with up to 198 devices to report an inci- j;r;;,;;;:�.,,�); , <br /> dent and activate the notification circuits in under 10 seconds. ;r�r�;�,�;��;; • <br /> With this improved polling,devices can be wired on standard -'``-`�` '�:''��• : a <br /> C;,.,,�,. . .,�, ,:,�.. <br /> h.:. ,, ,.., . .,,.• ; <br /> lwisted,unshielded wire up to a distance of 10,000 feet. °'����s��;�•i+..,°:,;.:;;;;.,�,,,,,�:;���1yo'r.��K�; <br /> The FireWarden-100-2 Rev 2's quick-remove chassis protects <br /> ihe electronics during construction. The backbox can be <br /> installed allowing field wiring to be pulled. When construction <br /> is completed,the electronics can be quickly installed with just <br /> two bolis. <br /> Available accessories include ANN•BUS devices as well as <br /> ACS LED, graphic and LCD annuncialors, and reverse polar- - <br /> irylcity box transmitter. _ <br /> The integral OACT transmits system status(alarms,superviso- � <br /> ries,troubles,AC loss, etc.)to a Central Station via the public �eatures <br /> switched telephone neiwork. It also allows remote and local <br /> programming of the control panel using the PS-Tools Upload/ • l-isted to UL standard 864,9th edition <br /> Download utility. In addition, the control panel may be pro- • On-board DACT <br /> grammed or interrogated oif-site via the pubiic switched tele- . Remote site or local USB port upload/download, using PS- <br /> phone network.Any personal computer with WindowsO XP or Tools. <br /> greater, a compatible modem, and PS-Tools, the Upload/ . Four Style Y (Class B) or two Class A (Style Z) NAC cir- <br /> Download soflware kit,may serve as a Service Terminal This cuits. U to 6.0 am s total NAC <br /> allows download of the entire program or upload of the entire � P P power when using <br /> program,history file,walktest data,current status and system optional XRM•248.) <br /> voltages. The panel can also be programmed through the • Selectable strobe synchronization for System Sensor, <br /> FACP's keypad or via a standard PS-2 computer keyboard, Wheelock,and Gentex devices. <br /> which can be plugged directly into the printed circuit board. • Remote Acknowledge,Silence,Reset and Drill via address- <br /> This permits easy typing of address labels and other program- able monitor modules or FDU-80, N-ANN-80 or ACS <br /> ming information. Annunciators. <br /> Version 4.0 firmware supports the following:ANN-bus devices, • ANN-BUS For connection to following optional modules(cannot <br /> NP-A100,USB port,NAC circuit diagnostics,a new report has be used if ACS annunciators are used): <br /> been added to the walk-test ihat lists untested devices, new -N-ANN-80(-W)Remote LCD Annunciator <br /> device types added: audio telephone type code for NFV-25/ _N-ANN-I/O LED Driver <br /> 50ZST, Photo Supervisory and auto-resettable Drill (non- <br /> latching). -N-ANN-S/PG Printer Module <br /> The FireWatch Series internet monitoring modules IPDACT-2 -N-ANN-RLY Relay Module <br /> and IPDACT-2UD permit monitoring of alarm signals over the -N-ANN-LED Annunciator Module <br /> Internet saving the monthly cost of two dedicated business -N-ANN-RLED Annunciator Module alarms only <br /> telephone lines. Although not required, the secondary tele- . ACS&Terminal-mode Annunciators: <br /> phone line may be retained providing backup communication <br /> over the public swiiched telephone line. -ACS Annunciators: Up to 32 ACM Series annunciators <br /> (ACM•16AT or ACM-32 series) Cannot be used if ANN- <br /> NOTE:Unless otherwise specrlred,the term"FrreWarden-i00-2"rs BUS devices are used. <br /> used in this document to refer to both the FireWarden-100-2 and <br /> the FireWarden-100-2E FACPs(Fire Alarm Controf Panefs). Like- -Terminal-mode Annunciators:Up to 32 FUU-BO annuncia- <br /> wise,"NFW2-100"re%rs to NFW2-f 00E as well. tors. <br /> • EIA-232 printer/PC interface (variable baud rate) on main <br /> circuit board,for use with optional UL-listed printer PRN-6. <br /> • Integral 80-character LCD display with backlighting. <br /> DN-60417.0•12/17/2009—Page 1 of 6 <br />