My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14582
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14582
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2014 10:42:21 AM
Creation date
6/12/2014 10:42:18 AM
Metadata
Fields
Template:
Building Department
Company Name
DIALYSIS CENTER
Building Department - Doc Type
Permit
Permit #
13-14582
Building Department - Name
BILL NYE REAL & SIMPLY THREE LL
Address
36819 EILAND BLVD UNIT 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � � . <br /> 72-3 4 NATIONAL FIRE ALARM CODE JOB# 1-6538 <br /> g, TYPE OF FIRE ALARM SYSTEM OR SERVICE(continued) Pe1''T"t� 145$2 <br /> [f Chapter 8, note the means of transmission from the protected premises to the central station: <br /> !� Digital .Alarm Communicator IP-Dact ' Multiplex � 2-way radio — ?v/q <br /> — AES IntelliNet � Other: <br /> 3.1 System Software <br /> Operating system(executive)software revision level: <br /> Site-specific software revision date: Revision completed by• <br /> 4. S[GNALING LINE CIRCUITS <br /> Characteristics of signaling line circuits connected to this system(see.�VFPA 72, Table 6.6.1) <br /> Quantity: 1 Style: 4 Class: <br /> 5. ALARM-INITIATING DEVICES AND CIRCUITS <br /> Characteristics of initiating device circuits connected to this system(see NFP.�1 72, Table 6.5) <br /> Quantity: 0 Style: Class: <br /> 5.1 Manual Initiating Devices <br /> 5.1.1 Manual Pull Station Number of manual pull stations: 4 <br /> Type of devices. � Addressable � Conventional I Coded I Transmitter � N/A <br /> 5.2 Automatic Initiating Devices <br /> 5.2.1 Area Smoke Detectors Number of Area smoke detectors: 6 <br /> Type of coverage: j Complete I� Partial area (� Selective I— Non-required <br /> Type of devices: (� Addressable I— Conventional � Coded I Transmitter (— N/A <br /> Type of smoke detector sensing technology• � [onization � Photo-electric (— Other: <br /> 5.2.2 Duct Smoke Detectors (— Alarm (� Supervisory Number of duct detectors: 8 <br /> Type of coverage• j Complete I Partial area I� Selective I Non-required <br /> Type of devices � Addressabte � Conventional j Coded � Transmitter � N/A <br /> 5.2.3 Heat Detectors Number of heat detectors: 2 <br /> Type of coverage: � Complete � Partial azea � Selective � Non-required <br /> Type of devices: (� Addressable I— Conventional � Coded � Transmitter (— N/A <br /> 5.2.4 Sprinkler Waterflow Detectors Number of water flow switches: 1 <br /> Type of devices: � Addressable j Coaventional � Coded I— Transmitter (— N/A <br /> 5.2.5 Alarm Veriticatioo Number of devices subject to alarm verification: <br /> Alarm verification on this system is: I�Disabled I— Enabled Set for seconds. <br /> FICURE 4.5.2.1 Record ojCompletion (2007 Edition I NFPA 72(pg.2 of S) <br />
The URL can be used to link to this page
Your browser does not support the video tag.