My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14582
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14582
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2014 10:42:21 AM
Creation date
6/12/2014 10:42:18 AM
Metadata
Fields
Template:
Building Department
Company Name
DIALYSIS CENTER
Building Department - Doc Type
Permit
Permit #
13-14582
Building Department - Name
BILL NYE REAL & SIMPLY THREE LL
Address
36819 EILAND BLVD UNIT 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
72-36 NATIONAL FIRE ALARM CODE JOB# I-6538 <br /> 8• ALARM IYOTIFICATIOIY DEVICES AND CIRCUITS(continued) Permit# 14582 <br /> 8.4 Types and Quantities of i�1on-voice Notification Appliances Installed <br /> Bells. With Visual device- Horns. j 2 With Visual device. j 2 <br /> Chimes: With Visual device Speaker• With Visual device• <br /> V isual devices without audible devices. j 6 Other <br /> 9. EMERGENCY CONTROL FUNCTIONS ACTIVATED <br /> ' Hold-open door releasing devices Smoke management or smoke control j Elevator recall <br /> I Door Unlocking I Other: <br /> 10.SYSTEM POWER SUPPLY <br /> 10.1 Primary Power <br /> Nominal Voltage 120vaC Amps 3.4ampS Overcurrent protection type: C[t'CUit Bt'eaker Amps 20amps <br /> Location(of primary supply Panelboard): Disconnecting means location: <br /> 10.2 Secondary Power <br /> Location: Bottom of FACU Type: Battery Back-up Nominal voltage: 24 <br /> Number of standby batteries: 2 Amp hour rating: 7.2 Current rating: 2.3 <br /> Calculated capacity of secondary power to drive the system: In standby mode: 24 Hours In alarm mode: S mins <br /> Location of emergency generator: Location of fuel storage: (� N/A <br /> 11.RECORD OF SYSTEM[NSTALLATION <br /> Fil!out after all installation is complete and wiring has been checked for opens,shorts,ground fau[ts,and improper branching, but before <br /> conducting operational acceptance tests. <br /> The system has been installed in accordance with the following NFPA standards: (Note any or all thut apply) <br /> � NFPA-72,National Fire Alarm Code � NFPA-70, National Electrical Code, Arricle 760 <br /> � Manufacturer's published instructions r" Other(please specify): <br /> System deviations fro r • nce A standards: <br /> Signed: Printed name: Yosvanni Castaneda Date: I 1/1 S/13 <br /> Organizati : Criiical System Solutions, LLC. Title: Inscallation Tech Phone: (727) 209-5122 <br /> 12.RECORD OF SYSTEM OPERATION <br /> All operational features and functions of this system were tested by or in the presence of the signer shown below,on <br /> the date shown below,and were found to be operating properly in accordance with the requirements of: <br /> � NFPA-72,National Fire Alarm Code � NFPA-70, National Electrieal Code,Artiele 760 <br /> (� Manufacturer's published instructions � Other(please specify): <br /> Documentation in accord I ction and Testing Form(Figure !0 6.2 3) is attached <br /> Signed: Printed name: Yosvanni Castaneda Date: 11/I S/13 <br /> Organization:�Critical System Solu[ions, LLC. Title: Installaiion Tech Phone: (727) 209-5122 <br /> FIC[IRE 4.5.2.1 Record of Completion (2007 Edition) ,�FPA 72(pg.,1 of S) <br />
The URL can be used to link to this page
Your browser does not support the video tag.