My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14597
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14597
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2014 7:42:58 AM
Creation date
6/13/2014 7:42:54 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
13-14597
Building Department - Name
HART,WILLIAM & WAGNER, WILLIAM
Address
39441 PATTIE RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM 405-10 <br /> Florida Code Compliance Checklist <br /> Florida Department of Business and Professional Regulations <br /> Residential Whole Building Performance Method <br /> ADDRESS PERMIT#� 611000 <br /> , FL, <br /> MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. <br /> COMPONENT SECTION SUMMARY OF REQUIREMENT(S) i CHECK <br /> Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed � <br /> Recessed lighting IC-rated as meeting ASTM E 283 Windows and <br /> Idoors = 0 30 cfm/sq ft. Testing or visual inspection required Fireplaces <br /> gasketed doors & outdoor combustion air. Must complete envelope <br /> leakage report or visually verify Table 402 4 2 <br /> Thermostat& 403.1 I At least one thermostat shall be provided for each separate heating and � <br /> controls cooling system Where forced-air furnace is primary system, <br /> programmable thermostat is required Heat pumps with supplemental <br /> electric heat must prevent supplemental heat when compressor can <br /> meet the load <br /> Ducts 403.22 All ducts, air handlers, filter boxes and building cavities which form the <br /> � primary air containment passageways for air distribution systems shall � <br /> be considered ducts or plenum chambers, shall be constructed and I <br /> sealed in accordance with Section 503 2 7 2 of this code <br /> 403.3 3 Building framing cavities shall not be used as supply ducts II <br /> Water heaters 403 4 Heat trap required for vertical pipe risers. Comply with efficiencies in <br /> Table 403 4 3 2 Provide switch or clearly marked circuit breaker <br /> (electric) or shutoff(gas) Circulating system pipes insulated to = R-2 � <br /> + accessible manual OFF switch <br /> Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical�— <br /> ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level I <br /> No make-up air from attics, crawlspaces, garages or outdoors adjacent <br /> to pools or spas <br /> Swimming Poo�s 403 9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1 � <br /> &Spas HP shall have the capability of operating at two or more speeds Spas <br /> and heated pools must have vapor-retardant covers or a liquid cover or <br /> other means proven to reduce heat loss except if 70% of heat from <br /> site-recovered energy Off/timer switch required Gas heaters minimum <br /> thermal efficiency=78°/a (82% after 4/16/13) Heat pump pool heaters � <br /> minimum COP=4 0 i <br /> Cooling/heating 403 6 Sizing calculation performed &attached. Minimum efficiencies per <br /> Tables 503.2 3 Equipment efficiency verification required Special <br /> equipment , occasion cooling or heating capacity requires separate system or i <br /> variable capacity system Electric heat>10kW must be divided into two � <br /> or more stages <br /> Ceilings/knee walls 405.2.1 R-19 space permitting <br /> 9/4/2013 10�32 AM EnergyGauge�USA-FlaRes2010 Section 405 4 1 Compliant Software Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.