CODES AND STANDARDS <br />• STRUCTURAL DESIGN BASED ON THE 2010 FLORIDA BUILDING CODE <br />• MINIMUM DESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES ASCE 7 <br />• BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE ACI 318* <br />• BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES ACI 530 <br />• AISC SPECIFICATION FOR STRUCTURAL STEEL DESIGN <br />• NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION <br />• AF &PA WOOD FRAME CONSTRUCTION MANUAL <br />GENERAL <br />* DO NOT SCALE DRAWINGS, USE GIVEN DIMENSIONS ONLY. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER <br />SCALE DIMENSIONS AT ALL TIMES. ANY DISCREPANCIES SHOULD BE BROUGHT TO THE DESIGNER <br />IMMEDIATELY. <br />* ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR IN THE FIELD. THE DIMENSIONS SHOWN ARE AS <br />ACCURATE AS THE BASE BUILDING DOCUMENTS PERMIT. ANY MAJOR DISCREPANCIES MUST BE BROUGHT TO <br />THE ATTENTION OF THE DESIGNER IMMEDIATELY. <br />* THE CONTRACTOR IS RESPONSIBLE FOR ALL METHODS, PROCEDURES, AND SEQUENCES OF <br />CONSTRUCTION. CONSTRUCTION SITE SAFETY, INCLUDING ALL ADEQUATE TEMPORARY BRACING AND <br />SHORING, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. <br />* IT IS THE CONTRACTORS RESPONSIBILITY TO EMPLOY THE NECESSARY PROFESSIONAL SEVICES TO <br />DETERMINE THE NECESSARY METHODS AND SUPPORTS REGARDING FORMING AND CONSTRUCTION LOADS. <br />• THE CONTRACTOR SHALL COORDINATE THE STRUCTURAL WORK WITH THE WORK OF ALL OTHER TRADES. <br />• ALL WORK SHALL BE OF THE HIGHEST QUALITY FOLLOWING THE MANUFACTURER'S SPECIFICATIONS ALONG <br />WITH THE BEST TRADE PRACTICES AND STANDARDS. <br />• ALL WORK AND MATERIALS SHALL BE GUARANTEED AGAINST POOR WORKMANSHIP AND DEFECTS. <br />• DRAWINGS ARE TO BE ISSUED TO THE SUBCONTRACTORS IN COMPLETE SETS SO THAT THEY KNOW THE <br />ARCHITECTURAL DETAILS AFFECTING THEIR WORK. <br />* THE CONTRACTOR IS RESPONSIBLE FOR ALL SPECIALTY TRADES. ANY AND ALL TRADES NOT MENTIONED IN <br />THESE DRAWINGS ARE THE RESPONSIBILITY OF THE CONTRACTOR. <br />* ALL WORK SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF THE FLORIDA BUILDING CODE OR THESE <br />DRAWINGS - WHICHEVER IS MORE STRINGENT. <br />* ALL WINDOW AND DOOR OPENING SIZES ARE NOMINAL. VERIFY MANUFACTURER'S ACTUAL OPENING <br />REQUIREMENTS. <br />DESIGN <br />• LIVE LOADS <br />ROOF 20 PSF <br />* DEAD LOADS: SPECIFIED MATERIAL WEIGHTS UTILIZED - REFERENCE DRAWINGS FOR SPECIFIED <br />SUPERIMPOSED DEAD LOADS FOR SPECIALTY STRUCTRUAL SYSTEMS. <br />* WIND LOADS: REFERENCE WIND DESIGN INFORMATION WITHIN THESE PLANS. <br />STRUCTURAL STEEL <br />• ALL STRUCTURAL STEEL SHALL BE ASTM A36 UNLESS NOTED OTHERWISE <br />• ALL STEEL SHALL BE SHOP PRIMED UNLESS NOTED OTHERWISE <br />• WELDING SHALL BE IN ACCORDANCE WITH AWS USING E -70 ELECTRODES. ALL WELDERS SHALL BE <br />CERTIFIED <br />* METAL SURFACES, GENERAL: FOR FABRICATION OF WORK WHICH WILL BE EXPOSED TO VIEW, USE ONLY <br />MATERIALS WHICH ARE SMOOTH AND FREE OF SURFACE BLEMISHES. <br />• STRUCTURAL STEEL ANGLES, PLATES AND BARS: ASTM A 36. <br />• STRUCTURAL STEEL I- SHAPES: ASTM A 992 <br />• HOT - FORMED STEEL TUBING: ASTM A 501. <br />• COLD- FORMED STEEL TUBING: ASTM A 500, GRADE B. <br />• BOLTS: ASTM A 325. <br />• ANCHOR BOLTS: ASTM A 307, HEADED TYPE UNLESS OTHERWISE INDICATED. <br />• UNFINISHED THREADED FASTENERS: ASTM A 307, GRADE A, REGULAR LOW CARBON STEEL BOLTS AND NUTS <br />HEAVY -HEX NUTS: ASTM A 563. <br />HARDENED STEEL WASHERS: ASTM F 436. <br />• STRUCTURAL STEEL PRIMER PAINT: FABRICATOR'S STANDARD RUST - INHIBITING PRIMER. <br />SHOP FABRICATION AND ASSEMBLY: FABRICATE AND ASSEMBLE STRUCTURAL ASSEMBLIES IN SHOP TO <br />GREATEST EXTENT POSSIBLE. FABRICATE ITEMS OF STRUCTURAL STEEL IN ACCORDANCE WITH AISC <br />SPECIFICATIONS AND AS INDICATED ON FINAL SHOP DRAWINGS. <br />* PROPERLY MARK AND MATCH -MARK MATERIALS FOR FIELD ASSEMBLY. FABRICATE FOR DELIVERY <br />SEQUENCE THAT WILL EXPEDITE ERECTION AND MINIMIZE FIELD HANDLING OF MATERIALS. <br />* WHERE FINISHING IS REQUIRED, COMPLETE ASSEMBLY, INCLUDING WELDING OF UNITS, BEFORE START OF <br />FINISHING OPERATIONS. PROVIDE FINISH SURFACES OF MEMBERS EXPOSED IN FINAL STRUCTURE FREE OF <br />MARKINGS, BURRS, AND OTHER DEFECTS. <br />• CONNECTIONS: WELD OR BOLT SHOP CONNECTIONS, AS INDICATED. <br />• BOLT FIELD CONNECTIONS, EXCEPT WHERE WELDED CONNECTIONS OR OTHER CONNECTIONS ARE <br />INDICATED. <br />* PROVIDE HIGH - STRENGTH THREADED FASTENERS FOR PRINCIPAL BOLTED CONNECTIONS, EXCEPT WHERE <br />UNFINISHED BOLTS ARE INDICATED. <br />* PROVIDE UNFINISHED THREADED FASTENERS FOR ONLY BOLTED CONNECTIONS OF SECONDARY FRAMING <br />MEMBERS TO PRIMARY MEMBERS (INCLUDING PURLINS, G(RTS AND OTHER FRAMING MEMBERS TAKING ONLY <br />NOMINAL STRESSES) AND FOR TEMPORARY BRACING TO FACILITATE ERECTION. <br />* HIGH STRENGTH BOLTED CONSTRUCTION: INSTALL HIGH - STRENGTH THREADED FASTENERS IN <br />ACCORDANCE WITH AISC "SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A 325 OR A 490 BOLTS" <br />(RCRBSJ). BOLTS SHALL BE "SNUGTIGHT <br />* HOLES FOR OTHER WORK: PROVIDE HOLES REQUIRED FOR SECURING OTHER WORK TO STRUCTURAL STEEL <br />FRAMING, AND FOR PASSAGE OF OTHER WORK THROUGH STEEL FRAMING MEMBERS, AS SHOWN ON FINAL <br />SHOP DRAWINGS. <br />* PROVIDE THREADED NUTS WELDED TO FRAMING, AND OTHER SPECIALTY ITEMS AS INDICATED TO RECEIVE <br />OTHER WORK. <br />• CUT, DRILL, OR PUNCH HOLES PERPENDICULAR TO METAL SURFACES. DO NOT FLAME CUT HOLES OR <br />ENLARGE HOLES BY BURNING. DRILL HOLES IN BEARING PLATES. <br />WOOD <br />• ALL FRAMING TO COMPLY WITH THE FBC (CURRENT EDITION) UNLESS THESE PLANS NOTE OTHERWISE <br />• ALL METAL CONNECTION HARDWARE BY SIMPSON UNLESS PRE - APPROVED BY THE ENGINEER <br />• WOOD IN CONTACT WITH EARTH, MASONRY, AND CONCRETE SHALL BE PRESSURE TREATED IN <br />ACCORDANCE WITH AITC -109 UNLESS A WATER BARRIER IS PROVIDED. WATER BARRIER SHALL BE IN <br />ACCORDANCE WITH THE FBC OR AT A MINIMUM 30LB FELT. <br />* COVER WOOD PRODUCTS TO PROTECT AGAINST MOISTURE. SUPPORT STACKED PRODUCTS TO PREVENT <br />DEFORMATION AND TO ALLOW AIR CIRCULATION. <br />* CONCEALED DIMENSIONAL LUMBER: 1) GRADING AGENCY: SOUTHERN PINE INSPECTION BUREAU, INC. (SPIB). <br />2) SIZES: NOMINAL SIZES AS INDICATED ON DRAWINGS, S4S. 3) MOISTURE CONTENT: S -DRY OR MC19. 4) <br />MISCELLANEOUS BLOCKING, FURRING, AND NAILERS AS FOLLOWS - LUMBER: S4S NO. 2 OR STANDARD GRADE <br />BOARDS: STANDARD OR NO. 3. <br />• EXPOSED DIMENSIONAL LUMBER: 1) GRADING AGENCY: SOUTHERN PINE INSPECTION BUREAU, INC. (SPIB). <br />2) SIZES: NOMINAL SIZES AS INDICATED ON DRAWINGS, S4S. 3) MOISTURE CONTENT: S -DRY OR MC19. <br />CONSTRUCTION PANELS: 1) CONCEALED PLYWOOD: PS 1, C -C PLUGGED, EXTERIOR GRADE. 2) EXPOSED <br />PLYWOOD: PS 1, A -D, INTERIOR GRADE. 3) ELECTRICAL COMPONENT MOUNTING: APA RATED SHEATHING, FIRE <br />RETARDANT TREATED. <br />* FASTENERS: HOT - DIPPED GALVANIZED STEEL FOR HIGH HUMIDITY AND TREATED WOOD LOCATIONS, <br />UNFINISHED STEEL ELSEWHERE U.N.O. <br />WOOD CONNECTORS <br />* UNLESS OTHERWISE NOTED IN THE MANUFACTURER'S CATALOG, BOLTS AND NAILS SHALL NOT BE <br />COMBINED. <br />* ALL NAILS SHALL BE COMMON UNLESS OTHERWISE NOTED IN THE MANUFACTURER'S CATALOG OR <br />SUBSTITUTED, BY THE ENGINEER OF RECORD, WITH A REDUCTION TAKEN. <br />* UNLESS OTHERWISE NOTED IN THE MANUFACTURER'S CATALOG, BENDING STEEL IN THE FIELD MAY CAUSE <br />FRACTURES AT THE BEND LINE. FRACTURED STEEL WILL NOT CARRY LOAD AND MUST BE REPLACED. WHEN <br />BENDING IS ALLOWED OR REQUIRED IN THE CATALOG, THE CONNECTOR SHALL BE ALLOWED ONE CYCLE <br />BEND, ONE TIME ONLY. <br />* ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD OR EXPOSED TO WEATHER SHALL BE HOT <br />DIPPED GALVANIZED WITH MINIMUM G180 PROTECTION. ALL NAILS, SCREWS, BOLTS, ETC REQUIRED FOR THE <br />CONNECTOR SHALL HAVE AN EQUAL OR GREATER PROTECTION AS THE CONNECTOR. DO NOT MIX <br />GALVANIZED AND STAINLESS STEEL MATERIALS. <br />* A FASTENER THAT SPLITS THE WOOD WILL NOT TAKE THE DESIGN LOAD. EVALUATE SPLITS TO DETERMINE <br />IF THE CONNECTION WILL PERFORM AS REQUIRED. DRY WOOD MAY SPLIT MORE EASILY AND SHOULD BE <br />EVALUATED AS REQUIRED. IF WOOD TENDS TO SPLIT, CONSIDER PRE - BORING HOLES WITH DIAMETERS NOT <br />EXCEEDING 0.75 OF THE NAIL DIAMETER (1997 NDS 12.1.3.1). <br />BUILT -UP LUMBER (MULTIPLE MEMBERS) MUST BE FASTENED TOGETHER TO ACT AS ONE UNIT TO RESIST <br />THE APPLIED LOAD. <br />* UNLESS OTHERWISE NOTED IN THE MANUFACTURER'S CATALOG, FILL ALL FASTENER HOLES WITH FASTENER <br />TYPES AS SPECIFIED IN THE MANUFACTURER'S CATALOG. <br />* ALL SPECIFIED FASTENERS MUST BE INSTALLED ACCORDING TO THE INSTRUCTIONS IN THE <br />MANUFACTURER'S CATALOG. <br />* BOLT HOLES SHALL BE A MINIMUM OF 1/32" AND A MAXIMUM OF 1/16" LARGER THAN THE BOLT DIAMETER <br />(NDS 8.1.2.1) <br />• INSTALL ALL SPECIFIED FASTENERS BEFORE LOADING THE CONNECTION. <br />• NAIL TOOLS WITH HOLE- LOCATION MECHANISMS MAY BE USED TO INSTALL CONNECTORS, PROVIDED THE <br />CORRECT QUANTITY AND TYPE OF NAILS ARE PROPERLY INSTALLED IN THE NAIL HOLES. <br />* JOIST SHALL BEAR COMPLETELY ON THE CONNECTOR SEAT, AND THE GAP BETWEEN THE JOIST END AND <br />THE HEADER SHALL NOT EXCEED 1/8 <br />ROOF (SHINGLE) <br />* ROOF SHEATHING SHALL BE MIN 1/2" PLYWOOD APA RATED EXPOSURE 1 C -D WOOD STRUCTURAL PANELS <br />AND SHALL SPAN NO MORE THAN 2' -0' <br />* SHEATHING SHALL SPAN WITH THE LONG DIMENSION PERPENDICULAR TO FRAMING WITH THE END JOINTS <br />STAGGERED <br />• FASTEN SHEATHING WITH 8D COMMON RING -SHANK NAILS @ 6 "cc MINIMUM U.N.O. <br />• FASTEN SHEATHING WITH 8D COMMON NAILS @ 4 "cC MINIMUM WITHIN ALL END ZONES - FOR END ZONE <br />DIMENSIONS AND LOCATIONS, SEE WIND DESIGN SECTION WITHIN THESE PLANS. <br />* FASTEN SHEATHING WITH 8D RING -SHANK NAILS @ 4 "CC MINIMUM WITHIN ALL CORNERS OF OVERHANGS - <br />FOR OVERHANG CORNER LOCATIONS, SEE WIND DESIGN SECTION WITHIN THESE PLANS. <br />* FASTEN SHEATHING WITH 8D RING -SHANK NAILS @ 4 "cc FOR A LENGTH OF 4' -0" PERPENDICULAR TO EACH <br />GABLE END. <br />• UNDERLAYMENT SHALL CONFORM TO ASTM D226 TYPE 1 OR ASTM 4869 TYPE 1. <br />• FOR ROOF SLOPES FROM 2:12 UP TO 4:12, UNDERLAYMENT SHALL BE A MINIMUM OF TWO LAYERS APPLIED <br />AS FOLLOWS: (1) STARTING AT THE EAVE, A 19 -INCH STRIP OF UNDERLAYMENT SHALL BE APPLIED PARALLEL <br />WITH THE EAVE AND FASTENED SUFFICIENTLY TO STAY IN PLACE. (2) STARTING AT THE EAVE, 36- INCH -WIDE <br />STRIPS OF UNDERLAYMENT FELT SHALL BE APPLIED OVERLAPPING SUCCESSIVE SHEETS 19 INCHES AND <br />STRIPS OF UNDERLAYMENT FELT SHALL BE APPLIED OVERLAPPING SUCCESSIVE SHEETS 19 INCHES AND <br />FASTENED SUFFICIENTLY TO STAY IN PLACE. <br />* FOR ROOF SLOPES 4:12 OR GREATER, UNDERLAYMENT SHALL BE A MINIMUM OF ONE LAYER OF <br />UNDERLAYMENT FELT APPLIED AS FOLLOWS: (1) STARTING AT THE EAVE, UNDERLAYMENT SHALL BE APPLIED <br />SHINGLE FASHION PARALLEL TO THE EAVE, LAPPED 2 INCHES (51 MM), AND FASTENED SUFFICIENTLY TO STAY <br />IN PLACE. <br />• ASPHALT SHINGLES SHALL COMPLY WITH ASTM D 225 OR ASTM D 3462. <br />• ATTACHMENT OF ASPHALT SHINGLES SHALL CONFORM WITH ASTM D 3161 (MODIFIED TO 110 MPH). ASPHALT <br />SHINGLE MANUFACTURER SHALL SUPPLY INSTALLATION SPECIFICATIONS IN CONFORMANCE WITH THE BASIC <br />WIND SPEED SHOWN ON THESE DRAWINGS. <br />* VALLEY LININGS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS BEFORE APPLYING ASPHALT SHINGLES. OPEN VALLEY FLASHING SHALL BE MINIMUM 16 <br />INCHES WIDE OF 2.5 -LB LEAD. CLOSED VALLEY FLASHING SHALL BE ONE PLY OF SMOOTH ROLL ROOFING AT <br />LEAST 36 INCHES WIDE AND COMPLYING WITH ASTM D 224. <br />* DRIP EDGE SHALL BE PROVIDED AT EAVES AND GABLES OF SHINGLE ROOFS, AND OVERLAPPED A MINIMUM <br />OF 2 INCHES, EAVE DRIP EDGES SHALL EXTEND 114 INCH BELOW SHEATHING AND EXTEND BACK ON THE <br />ROOF A MINIMUM OF 2 INCHES (51 MM). DRIP EDGE SHALL BE MECHANICALLY FASTENED A MAXIMUM OF 12 <br />INCHES ON CENTER. <br />* BASE AND CAP FLASHING SHALL BE MINIMUM 2.5 -LB LEAD. <br />SYMBOL DEFINITIONS I MMEARTH COMPACTED <br />FILL - SEE GENERAL NOTES <br />SECTION CALL FOR REQUIREMENTS. <br />ECTION CALL NUMBER <br />1 <br />1.1 <br />RAWING NUMBER <br />REFERENCED <br />ELEVATION CALL <br />LEVAT10N CALL NUMBER <br />to <br />1,1 <br />RAWING NUMBER <br />REFERENCED <br />DETAIL CALL <br />ETAIL CALL LETTER <br />A AREA <br />1.1 DETAILED <br />RAWING NUMBER <br />REFERENCED <br />STEEL - SEE GENERAL NOTES <br />FOR REQUIREMENTS AND <br />CORROSION PROTECTION. <br />WOOD BEARING <br />WALL - SEE DETAILS <br />FOR REQUIREMENTS. <br />STUCCO -SEE GENERAL NOTES FOR <br />REQUIREMENTS -STUCCO FINISH TO <br />' <br />MATCH EXISTING OR CHOSEN BY <br />O WNER. <br />CONCRETE -SEE <br />•� • <br />GENERAL NOTES <br />' <br />FOR REQUIREMENTS. <br />11 IT[] <br />CONCRETE MASONRY UNIT WALL <br />CONSTRUCTION - SEE GENERAL <br />NOTES FOR REQUIREMENTS AND <br />OUT SPECIFICATIONS. <br />SHINGLE ROOF - EXISTING <br />ROOF DECKING - EXISTING —\ <br />EXISTING PRE - ENGINEERED TRUSS SYSTEM <br />12 <br />MATCH EXISTING I <br />DRIP EDGE <br />TRIM EXISTING TRUSS <br />CHORDS PROVIDE 2x6 <br />EA. SIDE NAIL W/ 4 -16d <br />TOP & BOTTOM <br />-2x4 FRAMING <br />@16" O.C. <br />I <br />TRIM BOARD j <br />HARDIPLA LAP SIDING � •II <br />MATCH EXISTING •�� <br />OVER 30# FELT W/ 6" LAPS <br />ATTACHED TO }" PLYWOOD <br />WALL SHEATHING ATTCHED I EXISTING <br />W/ 8d COMMONS @ 6' O.C. 3 -2x12 <br />FRAMING FOR <br />SOFFIT <br />VENTED SOFFIT <br />MATCH EXISTING <br />2 <br />/ TRIM EXISTING <br />/ ANGLE <br />SECTION- <br />- O SCALE: 314'= V -0" <br />EXISTING BUILDINGS - FBC 2010 <br />REPAIRS (CHAPTER 5) <br />* THIS PROJECT HAS SUSTAINED LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE AND THEREFORE DAMAGED <br />ELEMENTS SHALL BE PERMITTED TO BE RESTORED TO THEIR PREDAMAGE CONDITION IN ACCORDANCE WITH <br />SECTION 506.2.1 <br />c <br />r` <br />A EXISTING TRUSS PLAN <br />, Q SCALE: 114"= 1' -0" <br />A PROPOSED TRUSS PLAN <br />1, Q SCALE: 114'= V -0" <br />ELEVA TION <br />O SCALE: 114'= V -0" <br />4 <br />c <br />NOTE: <br />THE DESIGNER - TO THE BEST OF HIS OR HER ABILITY - HAS <br />PROVIDED INFORMATION WITHIN THESE DRAWINGS THAT <br />REPRESENTS EXISTING CONDITIONS. ANY DESCREPENCIES <br />BETWEEN ACTUAL FIELD CONDITIONS AND THESE DRAWINGS <br />SHOULD BE BROUGHT TO THE DESIGNERS ATTENTION <br />IMMEDIATELY. THE GENERAL CONTRACTOR SHALL VERIFY <br />ALL EXISTING FIELD CONDITIONS SUCH AS (BUT NOT LIMITED <br />TO) DIMENSIONS, ELEVATIONS, WINDOW AND DOOR SIZES, <br />EXTERIOR AND INTERIOR FINISHES, TRUSS LAYOUT, ROOF <br />SLOPE AND OVERHANG, ELECTRICAL AND HVAC <br />REQUIREMENTS. THE REPAIRS OUTLINED WITHIN THESE <br />DRAWINGS SHALL CONFORM TO THE FLORIDA BUILDING CODE <br />- EXISTING BUILDINGS - REPAIRS. ALL REPAIR MATERIALS AND <br />COMPONENTS SHALL MATCH ALL EXISTING FINISHES AND <br />MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE - <br />THE MORE STRINGENT SHALL APPLY. <br />A <br />Q <br />Q <br />130 <br />O j O j O <br />I I <br />1 I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />---�-------------------- - - -4 -- <br />O I O l O <br />� I <br />ROOF (PLAN VIEW) <br />120 1 2n_ <br />ASCE 7 -10 WIND DESIGN INFORMATION FOR LOW RISE BUILDINGS <br />BASIC WIND SPEED = 140 MPH (3-SECOND GUST) <br />RISK CATEGORY = ii <br />EXPOSURE CATEGORY = B <br />Kd = 1.0 (Kd = 0.85 WHEN LOAD FACTORS ARE USED - ASCE TABLE 26,6 -1) <br />Kz1= 1.0 <br />ENCLOSED BUILDING <br />MEAN ROOF HEIGHT = < 30 FEET <br />ASCE 7 -10 COMPONENT AND CLADDING WIND PRESSURE - FIGURE 30.5 -1 <br />ROOF 7 TO 27 DEGREES <br />ROOF ZC,NE 1 = X20.3, -32.3 FSF <br />ROOF ZONE 2= *20.3, -5e.2 PSF <br />ROOF ZONE 3 = +20,3, -83.1 PSF <br />OVERHANG ZONE 2 = -65.7 PSF <br />OVERHANG ZONE 3 = -110.8 PSF <br />WALL ZONE 4 = +35.3.-38.2 PSF <br />WALL ZONE 5 = +353,47.2 PSF <br />ZONE '41DTH- A =8.7FT <br />130 <br />150 <br />180 <br />170 <br />�i <br />O <br />M <br />N <br />co <br />M <br />U) U <br />L J <br />®n= <br />ce W ct <br />Q I <br />ZOW <br />=0N <br />Q W <br />J <br />N <br />r <br />N <br />Cq <br />00 <br />co <br />COPYRIGHT @ 2013 <br />These drawings are for <br />the exclusive use of <br />Florida Engineering <br />Solutions, Inc. and <br />therefore, are not to be <br />duplicated or reproduced <br />in any manner without the <br />expressed written consent <br />of Florida Engineering <br />Solutions, Inc. <br />`\\111111`1/// <br />`��� � • � .... •�j>j�� /jam <br />i�•� 0 Q•. <br />Lij * n Q 0: z <br />,5 ° <br />ii ••'•' Z Q <br />REVISIONS <br />ZL <br />A <br />A <br />A4 <br />Project Number: <br />13 - 3308 - 402 <br />Check By: J. H. <br />Date: 08 / 07 / 13 <br />Drawn By: J.A. <br />Date: 08 / 06 / 13 <br />DRAWING NUMBER <br />■ <br />