Laserfiche WebLink
. • • _ • . _ • • _ � _ <br /> AED Graph <br /> 15000 <br /> 10000 <br /> � <br /> ti <br /> 0 <br /> J <br /> 5000 <br /> 0 <br /> 8am 9am l0am llam 12pm lpm 2pm 3pm 4pm Spm 6pr�i 7pm 8pm <br /> — Hourly Loads —Average <br /> � � � � � . <br /> System equipment selection will be made using the following derived values <br /> Glass (E) 112 sq. ft. <br /> Glass (S) 16 sq. ft. <br /> Glass (N) 16 sq. ft. <br /> Glass (W) 79 sq. ft. <br /> Summer Outdoor 91�F <br /> Summer Wet Bulb 77°F <br /> Summer Indoor �5�F <br /> Summer Design Grains 50% <br /> Winter Outdoor 40°F <br /> Winter Indoor �p�F <br /> Sensible Cooling 27,121 Btuh <br /> Latent Cooling 5,400 Btuh <br /> Required Cooling Airflow 1 233 CFM <br /> , <br /> Sensible Heating 22,157 Btuh <br /> Required Heating Airflow 288 CFM <br /> All calculations are based upon approved hvac industry standards and procedures,and comply with all local, <br /> state and federal code requirements.All computed results are Estimates.Product provided by Energy Design <br /> Systems and Idea Tree <br />