Laserfiche WebLink
.�'�' - �r,^ ' - `^ r " ' �r ' <br /> .. . G J .L l,...� ...+ y �Y L�� . . �� I ..L�S <br /> R=R'saitlaritial �ight Co�►11f�erClel'HV�IC Loads , -"�'-� � " EIiCe Softwaro Dewelopment;lnc � !' <br /> , I �4nd.5erv:�ces;;($arasota�' ~ , � � � , �. Hasse4qulst Resfdent <br /> ,., <br /> 'I i�:Sara�ata.:,Ft.34234. .. . . P89c:'�.� <br /> .. ' -- <br /> � <br /> II M�scellaneous Report _ <br /> . ., -�--� - <br /> .,. „ . „ _ <br /> _ <br /> '�lh����a�a. . t � ',� , . I��$irlti � , � '1TY�t Bufb � R I_t=1'O�yr,, ,• , Jndoo(,,r, , .i�doo.f Gr,�lns,i <br /> I <br /> � .G....� . .... .., . ,. . ,. <br /> !�. e u _Re1;J-lum Qry.�ufb biffe.�nc,e., <br /> Winter• 40 37 52 80% n/a 70 n/a <br /> Summer: 91 77 54% 50% 75 52.95 <br /> , . . <br /> i'Du�ct;;�izi'r�g;iripotb � � . <br /> ,, , ., ,... . � <br /> ; Main Trunk Runouts � - '� 'I <br /> Calcul8te. Yes Yes , <br /> ', Use Schedule• Yes Yes I <br /> Roughness Factor. 0 00300 0 01000 �', <br /> ' Pressure Drop: 0 1000 in.wg./100 ft. 0 1000 in.wg./100 ft. <br /> Minimum Velocity. 650 ft./min 450 ft./min � <br /> Maximum Velocity� 900 fi.lmin 750 ftJmin <br /> Minimum Height: 0 in. 0 in <br /> ,' Maximum Height: 0 in_ p in , <br /> I �"�Ji�t�iii�'�hr`r^ba�a ' ,,. ,� ;,, ,:, ., .. , � � ,;, - „ , , - .. . ,,. . . <br /> ,.. ° " " , ; - , ,-�� - <br /> _ __. winter Summe� _. .. .:J <br /> i Infiltration Specified 1 134 AUhr(rm � �� AC/hr(rm <br /> i specifiedj spec�fied) <br /> I 225 CFM 225 CFM <br /> i Infiltration Actual 1 134 AC/hr(rm 1.134 AC/hr(rm <br /> specified) specified) <br /> Above Crade Volume. X 11.904 Cu.ft. X 11.904 Cu ft �i <br /> 13,500 Cu.ft./hr 13,500 Cu ft./hr <br /> X 0.0167 X 0.0167 <br /> , Tot21 Building Infiltration: 225 CFM 225 CFM <br /> I Total Building Ventilation 225 CFM 225 CFM <br /> —System 1--- <br /> Infiltration �, Ventilation Sensible Gain Multiplier 17 59 = (1 10 X 0.999 X 16 00 Summer Temp, Difference) � <br /> tnfiltration 8 Ventilation Latent Gain Multiplier 35 98 = (0 69 X 0.999 X 52 95 Grains Dlfference) <br /> Infiltration 8,Ventilat�on Sensible Loss Multiplier: 32 98 = (1.10 X 0 999 X 30.00 Winter Temp. Difference) <br /> � Winter Infiltration Specified� 1.134 AC/hr(rm specified)(225 CFM) <br /> Summer Infiltration Specified. �.134 AC/hr(rm specifled) (225 CFM) ; <br /> � <br /> il <br /> i <br /> r I <br /> � � <br /> i <br /> j <br /> � � <br /> � <br /> ; <br /> � ; <br /> . .. ._ . . � <br /> C�\Users\JaosnlDocuments\Elite SoftwarelRhvac 9 ProjectslPIPER,H.rh9 Monday, October28, 2013, 2:21 PM <br />