Laserfiche WebLink
. • --2,__ <br /> �--� " i -' 1 ' ` -� ---_ <br /> i "- l_ � ` __ ___r. I <br /> �' � I <br /> � i ' <br /> , ;� Force Enh neering&Testin�Inc. '�� ; <br /> ` ' 19530 Ramblewood Drivc �`J <br /> Humble,T"X 77338 <br /> Code COmplianCe: The product described herein has demonstrated compliance with <br /> The Florida Building Code 2010,Section 15043.2,1504 7. <br /> Evaluation Report Stope: The product evaluation is limited to compliance with the structural wind load <br /> requirements of the Florida Building Code 2010,as relates to Rule 9N-3. <br /> Performanee Standards: The product described herein has demonstrated compliance with. <br /> ■ UL 580-06-Test for Uplift Resistance of Roof Assemblies <br /> ■ UL 1897-Q4-Uplift Test for Roof Covering Systems, <br /> ■ FM 4471,Section 5.4-Foot Traffic Resistance Test <br /> Reference Data: 1. UL 580-94/1897-98 Uplift Test <br /> Force Engineering&Testing,Inc.{FBC Organization#TST-5328) <br /> Report No. 117-00407T-09,Dated il/16/09 <br /> 2. FM 4471-95,Section 5 4 Foot Traffic Resistance Test <br /> Force Engineering&Testing,Inc.(FBC Organization#TST-5328) <br /> Report No. 117-0238T-09E,Dated 07/21/2009 <br /> 3. Certificate of Independence <br /> By Terrence E.Wolfe,P.E.(No 44923)@ Force Engineering&Testing,Inc. <br /> (FBC Organization#ANE ID• 1920) <br /> TeSt SWndard Equivalenty: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. <br /> 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. <br /> QualityAssurance Entity: The manufacturer has established compliance of roof panel products in <br /> accordance with the Florida Building Code and Rule 9N-3.005(3)for <br /> manufacturing under a quality assurance program audited by an approved <br /> quality assurance entity. <br /> Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2010,including Section <br /> 1507 4.2 and in accordance with Manufacturers recommendations. For slopes <br /> less than 3:12,lap sealant must be used in the panel side laps. <br /> Installation: Install per manufacturer's recommended details. <br /> Underlayment: Per Manufacturer's installation guidelines per Florida Buildirig Code 2010 Section <br /> 1507.4.5. <br /> ,,,��Itf11/1f1l�I <br /> ,�� �N.0 E_ �. � �i <br /> :�����. � C � N S� �'n��i <br /> r .<. . •t��Y, .- <br /> ' � ' Wo.4�9�� .. 'rr, � '', <br /> � � . ., ", ,e <br /> i,'.',�,?���..,t,��� _ *'" _'" .#�, <br /> � _ `- � '- --' . .. <br /> � �' STATE QF ;�^�r, <br /> %a'. A �, `�� <br /> %��;., � a R x ��.��,�;: <br /> �� ',,, ��4t�ti�ti�����`. <br /> FL# 11651.27 Rl <br /> February 22, 2012 <br />