My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
13-14689
Zephyrhills
>
Building Department
>
Permits
>
2013
>
13-14689
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2014 8:05:28 AM
Creation date
7/28/2014 8:05:17 AM
Metadata
Fields
Template:
Building Department
Company Name
HOBBY LOBBY
Building Department - Doc Type
Permit
Permit #
13-14689
Building Department - Name
MERCHANTS STATION LLC
Address
7333 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Couplings I Rigid I Style 009N I Publication 10 64 <br /> Style 009N Dimensions: <br /> �Y� �Z� �Y� �Z� <br /> X X <br /> Style 009N Pre-Assembled Style 009N Joint Assembled <br /> (Push On Condition) <br /> Dimensions <br /> Actual Maximum Maximum Allow. Pre-assebled ; <br /> Nominal Outside Working End Pipe End (Stab in Condition) � Joint Assembled yye r ht <br /> B <br /> Size Diameter Pressure' Load' Separation2 BolUNut3 X � Y ' X Y Z Each <br /> inches inches psi Ibs. inches (No.)size inches inches � inches inches inches Ibs. <br /> mm mm kPa N mm inches mm mm mm mm mm kg <br /> 1 Ya 1.660 365 790 0.10 (2)3/s x 2 3.10 i 4.90 � 2.70 4.90 1.92 1 4 <br /> 32 42.4 2517 3514 2.54 (M)10 x 2 79 124 69 124 49 0.7 <br /> 1 Yz 1.900 365 1035 0.10 (2)3/e x 2 330 � 5.10 � 3.00 5.10 1.92 1.5 <br /> 40 483 2517 4604 2.54 (M)10 x 2 84 129 76 129 49 0.7 <br /> 2 2375 365 1616 0.12 (2)�/e x 2 3.90 5.60 � 3.50 5.60 1.95 1.9 <br /> SO 603 2517 77 93 3.05 (M)10 x 2 99 � 142 89 142 50 0.9 <br /> 2'/: 2.875 365 2370 0.12 (2)�/e x 2�h 4.50 ! 6.10 � 4.00 6.10 1.95 2.1 <br /> 65 73.0 2517 10542 3.05 (M)10 x 2 Yx 114 155 102 7 55 50 1.0 <br /> 76.1 mm 3.000 365 2580 0.12 (2)3/e x 2�h 4.56 � 6.00 4.05 6.06 1.94 2.1 <br /> 76.1 2517 11476 3.05 (M)10x2�h 115.7 152.5 i 102,8 153.9 49.2 1.0 <br /> 3 3.500 365 3512 0.12 (2)3/e x 2Yz 5.10 6.70 � 4.60 6.70 1.95 23 <br /> 80 88.9 2517 15622 3.05 (M)lOx2Yx 129 170 117 170 50 1.0 <br /> 4 4.500 365 5805 0.17 (2)3/e x 2�/: 5.95 7.80 5.54 7 47 2.14 2.9 <br /> 100 1143 2517 25822 432 (M)10x2Ya 151 199 141 190 SS 13 <br /> 108.0 mm Refer to Submittal 10.61 <br /> 133.0 mm Refer to Submittal 10.61 <br /> 139.7 mm Refer to Submittal 10.67 <br /> 165.1 mm Refer to Submittal 10.61 <br /> 6 Refer to Submittal 10.61 <br /> 150 <br /> 1 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSD steel pipe,standard rol'or cut grooved in <br /> accordance with Victaulic specifications.See page 1 of this document for Listed/Approved ratings on other pipe.WARNING:FOR ONE TIME FIELD TEST ONLY, <br /> the Maximum Joint Working Pressure may be increased to 1 'fz times the figures shown in the chart on page 1,specrfic to pipe schedul?and size. <br /> 2 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZ couplings are considered rigid connect�ons and will not <br /> accommodate expansion or contraction of the piping system. <br /> 3 Number of bolts reqwred equals number of housing segments. <br /> General NMes: <br /> NOTE.When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For <br /> FireLock EZ Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ" <br /> marking on the inside face.Non-Victaulic end cap products shall not be used wdh Style 009N couplings.IMPORTANT Gaskets intended for the Style 009 or Style <br /> 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between couphng styles. <br /> Use Of Flushseal Gaskets For Dry Pipe Systems <br /> NOTE RreLock EZ couplings are supplied with FireLOCk EZ Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once�nstalled provides <br /> the same benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the <br /> FireLock EZ couplings. <br /> InsWllation Note <br /> Reference should always be made to the L100 Victaulic Field Installahon Handbook for This product shall be manufactured by Victaulic or to Victauhc specifications.All products <br /> the product you are installmg Handbooks are induded wdh each shipment of Victaulic to be installed in accordance with current Victauhc installation/assembly instructions. <br /> p�oducts for complete installation and assembly data,and are avatlable in PDF format VictaWic reserves the right to change product specrfications,designs and standard <br /> on our website at www victauhc com eqwpment without notice and wdhout incurnng obligahons. <br /> Warranty Trademarks <br /> Refer to the Warranty secdon of the current Price List or contact Victaulic for detatls Victaulic and FireLock EZ are registered trademarks of Victauhc Company <br /> 10.64 7072 Rev.C Updated OS/2013 �O 2013 Victaulic Company.All rights reserved. <br /> victaulic.com 3 iCtauli� <br />
The URL can be used to link to this page
Your browser does not support the video tag.