Laserfiche WebLink
TRINITY ERD <br /> 5.5.2.4 Maximum Desian Pressure = -90 osf. <br /> Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. <br /> Primer: (Optional) ASTM D41 <br /> Underlayment: Polystick TU, Polystick TU P, Polystick TU Plus, Polyflex SAP, PolyFlex SAP FR, <br /> Mule-Hide SA-APP Cap Sheet and Mule-Hide SA-APP Cap Sheet (FR) <br /> 5.5.2.5 All other direct-deck, adhered Polyglass underlayment systems beneath foam-on tile systems <br /> carry a Maximum Design Pressure of-45 psf. <br /> 5.5.3 Bond-to-Insulation: <br /> r Polystick, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) <br /> self-adhered to: ASTM C1289, Type II, Class 1 polyisocyanurate or Type V <br /> polyisocyanurate-composite insulation; DensDeck DuraGuard; DensDeck Prime; or <br /> SECUROCK Gypsum-Fiber Roof Board. <br /> ➢ Elastoflex S6 G or S6 G FR in hot asphalt to: DensDeck Prime or SECUROCK Gypsum-Fiber <br /> Roof Board. <br /> ➢ Polyflex G or G FR torch-applied to: ASTM D41 primed structural concrete; DensDeck <br /> Prime or SECUROCK Gypsum-Fiber Roof Board. <br /> For installation under mechanically attached prepared roof coverings, insulation shall be <br /> attached per minimum requirements of the prepared roof covering manufacturer's Product <br /> Approval. For installations under foam-on tile systems, insulation attachment shall be <br /> designed by a qualified design professional and installed based on testing of the <br /> insulation/underlayment system in accordance with FM 4470, Appendix K or TAS 114, <br /> Appendix J. <br /> 5.5.4 Bond to Mechanicallv Attached Base Layer: <br /> y Polystick, Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) <br /> Dual Pro or Tile Pro self-adhered to: ASTM D226, Type I or II felt; Elastobase; Elastobase <br /> P or Mule-Hide Nail Base. <br /> i- Elastoflex S6 G or S6 G FR in hot asphalt to: ASTM D226, Type I or II felt; Elastobase; <br /> Elastobase P or Mule-Hide Nail Base. <br /> Y Polyflex G or G FR torch-applied to: Elastobase; Elastobase P or Mule-Hide Nail Base. <br /> For installations under mechanically attached prepared roof coverings, base layer shall be <br /> attached per minimum codified requirements. For installations under foam-on tile systems, <br /> base layer shall be attached per minimum requirements of FRSA/TRI 07320/8-05 or RAS 120. <br /> 5.6 Exposure Limitations: <br /> 5.6.1 Elastobase, Elastobase P, shall not be left exposed for longer than 30-days after installation. <br /> 5.6.2 Polystick IR-Xe, Polystick TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than <br /> 90-days after installation. <br /> 5.6.3 Polystick MTS, TU, TU P or TU Plus shall not be left exposed for longer than 180-days after <br /> installation. <br /> 5.6.4 Polyflex SAP or SAP FR, or Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not <br /> have an exposure limitation, unless the prepared roof covering is to be adhesive-set tile, in <br /> which case the maximum exposure is 30 days. <br /> 5.6.5 Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless <br /> the prepared roof covering is to be adhesive-set tile (Elastoflex S6 G or Polyflex G), in which <br /> case the maximum exposure is 180 days. <br /> Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R13 <br /> Certifcate ofAuthorization#9503 FL5259-R18 <br /> Revision 13: 04/26/2013 <br /> Page6of10 <br />