Laserfiche WebLink
TRINITY ERD <br /> 6. INSTALLATION: <br /> 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published <br /> installation requirements subject to the Limitations set forth in Section 5 herein and the <br /> specifics noted below. <br /> 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the <br /> substrate thoroughly to remove any dust and debris prior to application, and prime the <br /> substrate (if applicable). <br /> 6.3 Elastobase Elastobase P or Mule-Hide Nail Base• <br /> 6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II <br /> underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. <br /> 6.3.2 For use in non-tile applications: <br /> 6.3.2.1 Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA <br /> recommendations for installing shingle underlayments and flashings <br /> 6.3.2.2 Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick, <br /> Polyflex SAP or SAP FR, Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or <br /> Tile Pro, self-adhered, Elastoflex S6 G or S6 G FR in hot asphalt or Polyflex G or G FR, torch <br /> applied. <br /> 6.3.3 For use in tile applications, reference is made to Polyglass published installation instructions in <br /> conjunction with FRSA/TRI 07320/8-05 Installation Manual, Fourth Edition, and Table 2 <br /> herein. <br /> 6.4 Polvstick MTS. IR-Xe, TU, TU P, TU Plus TU Max Polvflex SAP or SAP FR Mule Hide <br /> SA-APP Can Sheet or SA-APP Cao Sheet (FR) Dual Pro or Tile Pro• <br /> 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment <br /> in FBC Sections 1507 for the type of prepared roof covering to be installed. <br /> 6.4.2 For non-tile applications: <br /> 6.4.2.1 All self-adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR <br /> and Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back-nailed in selvage <br /> edge seam in accordance with Polyglass / Mule-Hide Back Nailing Guide. Nails shall be <br /> corrosion resistant, li gauge ring-shank type with a minimum 1-inch diameter metal disk or <br /> Simplex-type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back- <br /> nailed using the above noted fasteners and spacing, in area marked "nail area, area para <br /> clavar" on the face of inembrane. The head lap membrane is to cover the area being back- <br /> nailed <br /> 6.4.2.2 All seal-lap seams (selvage laps) must � <br /> be firmly rolled with a minimum 28 Ib. ' ' � <br /> hand roller to ensure full contact and '� � <br /> adhesion. For Dual Pro and Tile Pro, '�� ��•" <br /> align the edge of the top sheet to the ��°,;� .-:� <br /> end of the glue pattern (the sheet will ' ° ^;;'w " <br /> overlap the fabric). ��' <br /> „�•• � . <br /> °�.- � <br /> �� ��h.�� F;�p� �� �C' <br /> ��.�# ' �� � <br /> �°� ��. <br /> View of Ovelap Seam of Dual Pro and Tile Pro <br /> Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R13 <br /> Certificate ofAuthorization#9503 FL5259-R18 <br /> Revision 13: 04/26/2013 <br /> Page 8 of 10 <br />