R W R W Building Consultants, Inc. <br /> B Consulting and Engmeering Services for ihe Building Industry <br /> C PA Dox 2?0 Yalrico,FL 33595 Pbone 813.G59 9197 <br /> Florida Board ofProfessional En��neers CMificate of AWhorization No 9811 <br /> Product Sub Category Manufacturer Product Name <br /> Category <br /> SitverLine Building Products Corporetion Series 2100-Modei 2111 <br /> Windows Single Hung One StNeritne Drive Extruded Vinyl Single Hung wndow <br /> North Brunswick,NJ 08902 Ylfith Flange <br /> Phone 732.435.1000 "Non-Im acY' <br /> Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F Schmidt,P.E.(System ID# <br /> 1998)for SilverLine Building Products based on Rule Chapter No.9N-3,Method 1d of the State of Florida Product <br /> Approval,Department of Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F Schmidt,P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named <br /> herein. <br /> Limitations: <br /> 1 This product has been evaluated and is in compliance with the 2010 Florida Building Code structural requirements excluding the"High <br /> Velocity Hurricane Zone". <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco. <br /> 3. When used in areas requiring wind borne debris protection,this product is required to be protected with an impact resistant covering <br /> that complies with Section�609 1.2 of the Florida Building Code <br /> 4 For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction <br /> 5. Site conditions that deviate from the details of drawing FL-14911 13 require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6 See drawing FL-14911 13 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1 Test Reaort No. Test Standard Testina laboratorv Siqned bv <br /> ATI 96884 01-109-47 AAMA/VVDMA/CSA 101/I.S.2/A440-08 Architectural Testing,Inc. Michael D Stremmel,P E. <br /> 2. Drawina No. Preaared bv Sioned 8 Sealed bv <br /> No.FL-14911 13 RW Building Consultants,Inc.(CA#9813) Lyndon F Schmidt,P.E. <br /> 3 Calculations Preaared bv Siqned 8 Sealed bv <br /> Anchoring RW Building Consultants,Inc.(CA#98'13) lyndon F Schmidt,P.E. <br /> 4 Qualiri Assurance <br /> Certificate of Pa�ticipation issued by Window and Door Manufacturers Association,certifying that SilverLine Building <br /> Products is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide `r//v <br /> 53 / <br /> v <br /> Ly�don F Schmidt,P.E. <br /> FL PE No.43409 <br /> 9l2412013 <br /> pF�gZ7 Sheet'I of 1 <br />